ABAP Select data from SAP table E1P0134 into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP E1P0134 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to E1P0134. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the E1P0134 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_E1P0134 TYPE STANDARD TABLE OF E1P0134,
      WA_E1P0134 TYPE E1P0134,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <E1P0134> TYPE E1P0134.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_E1P0134.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM E1P0134
  INTO TABLE IT_E1P0134.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM E1P0134
*  INTO TABLE @DATA(IT_E1P01342).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_E1P0134 INDEX 1 INTO DATA(WA_E1P01342).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_E1P0134 ASSIGNING <E1P0134>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<E1P0134>-PERNR = 1.
<E1P0134>-INFTY = 1.
<E1P0134>-SUBTY = 1.
<E1P0134>-OBJPS = 1.
<E1P0134>-SPRPS = 1.
ENDLOOP.

LOOP AT IT_E1P0134 INTO WA_E1P0134.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_E1P0134-ENDDA, sy-vline,
WA_E1P0134-BEGDA, sy-vline,
WA_E1P0134-SEQNR, sy-vline,
WA_E1P0134-AEDTM, sy-vline,
WA_E1P0134-UNAME, sy-vline,
WA_E1P0134-HISTO, sy-vline.
ENDLOOP. *Add any further fields from structure WA_E1P0134 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_E1P0134 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_E1P0134 INTO WA_E1P0134. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_E1P0134_STR,
PERNR TYPE STRING,
INFTY TYPE STRING,
SUBTY TYPE STRING,
OBJPS TYPE STRING,
SPRPS TYPE STRING,
ENDDA TYPE STRING,
BEGDA TYPE STRING,
SEQNR TYPE STRING,
AEDTM TYPE STRING,
UNAME TYPE STRING,
HISTO TYPE STRING,
ITXEX TYPE STRING,
REFEX TYPE STRING,
ORDEX TYPE STRING,
ITBLD TYPE STRING,
PREAS TYPE STRING,
FLAG1 TYPE STRING,
FLAG2 TYPE STRING,
FLAG3 TYPE STRING,
FLAG4 TYPE STRING,
RESE1 TYPE STRING,
RESE2 TYPE STRING,
PFART TYPE STRING,
PFNUM TYPE STRING,
UNBER TYPE STRING,
UNBEV TYPE STRING,
GRUND TYPE STRING,
UNBS0 TYPE STRING,
UNBS1 TYPE STRING,
UNBS2 TYPE STRING,
UNBS3 TYPE STRING,
UNBS4 TYPE STRING,
UNBS5 TYPE STRING,
UNBS6 TYPE STRING,
UNBS7 TYPE STRING,
UNBS8 TYPE STRING,
UNBS9 TYPE STRING,
UNBN0 TYPE STRING,
UNBN1 TYPE STRING,
UNBN2 TYPE STRING,
UNBN3 TYPE STRING,
UNBN4 TYPE STRING,
UNBN5 TYPE STRING,
UNBN6 TYPE STRING,
UNBN7 TYPE STRING,
UNBN8 TYPE STRING,
UNBN9 TYPE STRING,
UNBU0 TYPE STRING,
UNBU1 TYPE STRING,
UNBU2 TYPE STRING,
UNBU3 TYPE STRING,
UNBU4 TYPE STRING,
UNBU5 TYPE STRING,
UNBU6 TYPE STRING,
UNBU7 TYPE STRING,
UNBU8 TYPE STRING,
UNBU9 TYPE STRING,
UNBE0 TYPE STRING,
UNBE1 TYPE STRING,
UNBE2 TYPE STRING,
UNBE3 TYPE STRING,
UNBE4 TYPE STRING,
UNBE5 TYPE STRING,
UNBE6 TYPE STRING,
UNBE7 TYPE STRING,
UNBE8 TYPE STRING,
UNBE9 TYPE STRING,
GRPVL TYPE STRING,END OF T_EKKO_STR. DATA: WA_E1P0134_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_E1P0134_STR-PERNR sy-vline
WA_E1P0134_STR-INFTY sy-vline
WA_E1P0134_STR-SUBTY sy-vline
WA_E1P0134_STR-OBJPS sy-vline
WA_E1P0134_STR-SPRPS sy-vline
WA_E1P0134_STR-ENDDA sy-vline
WA_E1P0134_STR-BEGDA sy-vline
WA_E1P0134_STR-SEQNR sy-vline
WA_E1P0134_STR-AEDTM sy-vline
WA_E1P0134_STR-UNAME sy-vline
WA_E1P0134_STR-HISTO sy-vline
WA_E1P0134_STR-ITXEX sy-vline
WA_E1P0134_STR-REFEX sy-vline
WA_E1P0134_STR-ORDEX sy-vline
WA_E1P0134_STR-ITBLD sy-vline
WA_E1P0134_STR-PREAS sy-vline
WA_E1P0134_STR-FLAG1 sy-vline
WA_E1P0134_STR-FLAG2 sy-vline
WA_E1P0134_STR-FLAG3 sy-vline
WA_E1P0134_STR-FLAG4 sy-vline
WA_E1P0134_STR-RESE1 sy-vline
WA_E1P0134_STR-RESE2 sy-vline
WA_E1P0134_STR-PFART sy-vline
WA_E1P0134_STR-PFNUM sy-vline
WA_E1P0134_STR-UNBER sy-vline
WA_E1P0134_STR-UNBEV sy-vline
WA_E1P0134_STR-GRUND sy-vline
WA_E1P0134_STR-UNBS0 sy-vline
WA_E1P0134_STR-UNBS1 sy-vline
WA_E1P0134_STR-UNBS2 sy-vline
WA_E1P0134_STR-UNBS3 sy-vline
WA_E1P0134_STR-UNBS4 sy-vline
WA_E1P0134_STR-UNBS5 sy-vline
WA_E1P0134_STR-UNBS6 sy-vline
WA_E1P0134_STR-UNBS7 sy-vline
WA_E1P0134_STR-UNBS8 sy-vline
WA_E1P0134_STR-UNBS9 sy-vline
WA_E1P0134_STR-UNBN0 sy-vline
WA_E1P0134_STR-UNBN1 sy-vline
WA_E1P0134_STR-UNBN2 sy-vline
WA_E1P0134_STR-UNBN3 sy-vline
WA_E1P0134_STR-UNBN4 sy-vline
WA_E1P0134_STR-UNBN5 sy-vline
WA_E1P0134_STR-UNBN6 sy-vline
WA_E1P0134_STR-UNBN7 sy-vline
WA_E1P0134_STR-UNBN8 sy-vline
WA_E1P0134_STR-UNBN9 sy-vline
WA_E1P0134_STR-UNBU0 sy-vline
WA_E1P0134_STR-UNBU1 sy-vline
WA_E1P0134_STR-UNBU2 sy-vline
WA_E1P0134_STR-UNBU3 sy-vline
WA_E1P0134_STR-UNBU4 sy-vline
WA_E1P0134_STR-UNBU5 sy-vline
WA_E1P0134_STR-UNBU6 sy-vline
WA_E1P0134_STR-UNBU7 sy-vline
WA_E1P0134_STR-UNBU8 sy-vline
WA_E1P0134_STR-UNBU9 sy-vline
WA_E1P0134_STR-UNBE0 sy-vline
WA_E1P0134_STR-UNBE1 sy-vline
WA_E1P0134_STR-UNBE2 sy-vline
WA_E1P0134_STR-UNBE3 sy-vline
WA_E1P0134_STR-UNBE4 sy-vline
WA_E1P0134_STR-UNBE5 sy-vline
WA_E1P0134_STR-UNBE6 sy-vline
WA_E1P0134_STR-UNBE7 sy-vline
WA_E1P0134_STR-UNBE8 sy-vline
WA_E1P0134_STR-UNBE9 sy-vline
WA_E1P0134_STR-GRPVL sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.