ABAP Select data from SAP table E1P0126 into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP E1P0126 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to E1P0126. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the E1P0126 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_E1P0126 TYPE STANDARD TABLE OF E1P0126,
      WA_E1P0126 TYPE E1P0126,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <E1P0126> TYPE E1P0126.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_E1P0126.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM E1P0126
  INTO TABLE IT_E1P0126.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM E1P0126
*  INTO TABLE @DATA(IT_E1P01262).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_E1P0126 INDEX 1 INTO DATA(WA_E1P01262).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_E1P0126 ASSIGNING <E1P0126>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<E1P0126>-PERNR = 1.
<E1P0126>-INFTY = 1.
<E1P0126>-SUBTY = 1.
<E1P0126>-OBJPS = 1.
<E1P0126>-SPRPS = 1.
ENDLOOP.

LOOP AT IT_E1P0126 INTO WA_E1P0126.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_E1P0126-ENDDA, sy-vline,
WA_E1P0126-BEGDA, sy-vline,
WA_E1P0126-SEQNR, sy-vline,
WA_E1P0126-AEDTM, sy-vline,
WA_E1P0126-UNAME, sy-vline,
WA_E1P0126-HISTO, sy-vline.
ENDLOOP. *Add any further fields from structure WA_E1P0126 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_E1P0126 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_E1P0126 INTO WA_E1P0126. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_E1P0126_STR,
PERNR TYPE STRING,
INFTY TYPE STRING,
SUBTY TYPE STRING,
OBJPS TYPE STRING,
SPRPS TYPE STRING,
ENDDA TYPE STRING,
BEGDA TYPE STRING,
SEQNR TYPE STRING,
AEDTM TYPE STRING,
UNAME TYPE STRING,
HISTO TYPE STRING,
ITXEX TYPE STRING,
REFEX TYPE STRING,
ORDEX TYPE STRING,
ITBLD TYPE STRING,
PREAS TYPE STRING,
FLAG1 TYPE STRING,
FLAG2 TYPE STRING,
FLAG3 TYPE STRING,
FLAG4 TYPE STRING,
RESE1 TYPE STRING,
RESE2 TYPE STRING,
VSART TYPE STRING,
EINDA TYPE STRING,
AUSDA TYPE STRING,
MITNR TYPE STRING,
PAUST TYPE STRING,
MFBZG TYPE STRING,
TEILK TYPE STRING,
ANWST TYPE STRING,
ANWAK TYPE STRING,
ANW65 TYPE STRING,
ANWVO TYPE STRING,
ANWUE TYPE STRING,
VERDA TYPE STRING,
GRPVL TYPE STRING,END OF T_EKKO_STR. DATA: WA_E1P0126_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_E1P0126_STR-PERNR sy-vline
WA_E1P0126_STR-INFTY sy-vline
WA_E1P0126_STR-SUBTY sy-vline
WA_E1P0126_STR-OBJPS sy-vline
WA_E1P0126_STR-SPRPS sy-vline
WA_E1P0126_STR-ENDDA sy-vline
WA_E1P0126_STR-BEGDA sy-vline
WA_E1P0126_STR-SEQNR sy-vline
WA_E1P0126_STR-AEDTM sy-vline
WA_E1P0126_STR-UNAME sy-vline
WA_E1P0126_STR-HISTO sy-vline
WA_E1P0126_STR-ITXEX sy-vline
WA_E1P0126_STR-REFEX sy-vline
WA_E1P0126_STR-ORDEX sy-vline
WA_E1P0126_STR-ITBLD sy-vline
WA_E1P0126_STR-PREAS sy-vline
WA_E1P0126_STR-FLAG1 sy-vline
WA_E1P0126_STR-FLAG2 sy-vline
WA_E1P0126_STR-FLAG3 sy-vline
WA_E1P0126_STR-FLAG4 sy-vline
WA_E1P0126_STR-RESE1 sy-vline
WA_E1P0126_STR-RESE2 sy-vline
WA_E1P0126_STR-VSART sy-vline
WA_E1P0126_STR-EINDA sy-vline
WA_E1P0126_STR-AUSDA sy-vline
WA_E1P0126_STR-MITNR sy-vline
WA_E1P0126_STR-PAUST sy-vline
WA_E1P0126_STR-MFBZG sy-vline
WA_E1P0126_STR-TEILK sy-vline
WA_E1P0126_STR-ANWST sy-vline
WA_E1P0126_STR-ANWAK sy-vline
WA_E1P0126_STR-ANW65 sy-vline
WA_E1P0126_STR-ANWVO sy-vline
WA_E1P0126_STR-ANWUE sy-vline
WA_E1P0126_STR-VERDA sy-vline
WA_E1P0126_STR-GRPVL sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.