ABAP Select data from SAP table E1P0077 into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP E1P0077 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to E1P0077. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the E1P0077 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_E1P0077 TYPE STANDARD TABLE OF E1P0077,
      WA_E1P0077 TYPE E1P0077,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <E1P0077> TYPE E1P0077.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_E1P0077.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM E1P0077
  INTO TABLE IT_E1P0077.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM E1P0077
*  INTO TABLE @DATA(IT_E1P00772).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_E1P0077 INDEX 1 INTO DATA(WA_E1P00772).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_E1P0077 ASSIGNING <E1P0077>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<E1P0077>-PERNR = 1.
<E1P0077>-INFTY = 1.
<E1P0077>-SUBTY = 1.
<E1P0077>-OBJPS = 1.
<E1P0077>-SPRPS = 1.
ENDLOOP.

LOOP AT IT_E1P0077 INTO WA_E1P0077.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_E1P0077-ENDDA, sy-vline,
WA_E1P0077-BEGDA, sy-vline,
WA_E1P0077-SEQNR, sy-vline,
WA_E1P0077-AEDTM, sy-vline,
WA_E1P0077-UNAME, sy-vline,
WA_E1P0077-HISTO, sy-vline.
ENDLOOP. *Add any further fields from structure WA_E1P0077 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_E1P0077 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_E1P0077 INTO WA_E1P0077. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_E1P0077_STR,
PERNR TYPE STRING,
INFTY TYPE STRING,
SUBTY TYPE STRING,
OBJPS TYPE STRING,
SPRPS TYPE STRING,
ENDDA TYPE STRING,
BEGDA TYPE STRING,
SEQNR TYPE STRING,
AEDTM TYPE STRING,
UNAME TYPE STRING,
HISTO TYPE STRING,
ITXEX TYPE STRING,
REFEX TYPE STRING,
ORDEX TYPE STRING,
ITBLD TYPE STRING,
PREAS TYPE STRING,
FLAG1 TYPE STRING,
FLAG2 TYPE STRING,
FLAG3 TYPE STRING,
FLAG4 TYPE STRING,
RESE1 TYPE STRING,
RESE2 TYPE STRING,
GRPVL TYPE STRING,
RACKY TYPE STRING,
MILSA TYPE STRING,
RELGN TYPE STRING,
SURVY TYPE STRING,
DISAB TYPE STRING,
VETST TYPE STRING,
DISDT TYPE STRING,
DISLE TYPE STRING,
MEDIC TYPE STRING,
EEOEX TYPE STRING,
ETHEN TYPE STRING,
RAC01 TYPE STRING,
RAC02 TYPE STRING,
RAC03 TYPE STRING,
RAC04 TYPE STRING,
RAC05 TYPE STRING,
RAC06 TYPE STRING,
RAC07 TYPE STRING,
RAC08 TYPE STRING,
RAC09 TYPE STRING,
RAC10 TYPE STRING,
RIFST TYPE STRING,
RCITY TYPE STRING,
SURPA TYPE STRING,
RELEA TYPE STRING,
SURSC TYPE STRING,
ABOTY TYPE STRING,
DTY01 TYPE STRING,
DTY02 TYPE STRING,
DTY03 TYPE STRING,
DTY04 TYPE STRING,
DTY05 TYPE STRING,
MTY01 TYPE STRING,
MTY02 TYPE STRING,
MTY03 TYPE STRING,
MTY04 TYPE STRING,
MTY05 TYPE STRING,
VETS1 TYPE STRING,
VETS2 TYPE STRING,
VETS3 TYPE STRING,
VETS4 TYPE STRING,
VETS5 TYPE STRING,
VETS6 TYPE STRING,
VETS7 TYPE STRING,
VETS8 TYPE STRING,
VETS9 TYPE STRING,
VETS10 TYPE STRING,
VETS11 TYPE STRING,
VETS12 TYPE STRING,
DCRDT TYPE STRING,END OF T_EKKO_STR. DATA: WA_E1P0077_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_E1P0077_STR-PERNR sy-vline
WA_E1P0077_STR-INFTY sy-vline
WA_E1P0077_STR-SUBTY sy-vline
WA_E1P0077_STR-OBJPS sy-vline
WA_E1P0077_STR-SPRPS sy-vline
WA_E1P0077_STR-ENDDA sy-vline
WA_E1P0077_STR-BEGDA sy-vline
WA_E1P0077_STR-SEQNR sy-vline
WA_E1P0077_STR-AEDTM sy-vline
WA_E1P0077_STR-UNAME sy-vline
WA_E1P0077_STR-HISTO sy-vline
WA_E1P0077_STR-ITXEX sy-vline
WA_E1P0077_STR-REFEX sy-vline
WA_E1P0077_STR-ORDEX sy-vline
WA_E1P0077_STR-ITBLD sy-vline
WA_E1P0077_STR-PREAS sy-vline
WA_E1P0077_STR-FLAG1 sy-vline
WA_E1P0077_STR-FLAG2 sy-vline
WA_E1P0077_STR-FLAG3 sy-vline
WA_E1P0077_STR-FLAG4 sy-vline
WA_E1P0077_STR-RESE1 sy-vline
WA_E1P0077_STR-RESE2 sy-vline
WA_E1P0077_STR-GRPVL sy-vline
WA_E1P0077_STR-RACKY sy-vline
WA_E1P0077_STR-MILSA sy-vline
WA_E1P0077_STR-RELGN sy-vline
WA_E1P0077_STR-SURVY sy-vline
WA_E1P0077_STR-DISAB sy-vline
WA_E1P0077_STR-VETST sy-vline
WA_E1P0077_STR-DISDT sy-vline
WA_E1P0077_STR-DISLE sy-vline
WA_E1P0077_STR-MEDIC sy-vline
WA_E1P0077_STR-EEOEX sy-vline
WA_E1P0077_STR-ETHEN sy-vline
WA_E1P0077_STR-RAC01 sy-vline
WA_E1P0077_STR-RAC02 sy-vline
WA_E1P0077_STR-RAC03 sy-vline
WA_E1P0077_STR-RAC04 sy-vline
WA_E1P0077_STR-RAC05 sy-vline
WA_E1P0077_STR-RAC06 sy-vline
WA_E1P0077_STR-RAC07 sy-vline
WA_E1P0077_STR-RAC08 sy-vline
WA_E1P0077_STR-RAC09 sy-vline
WA_E1P0077_STR-RAC10 sy-vline
WA_E1P0077_STR-RIFST sy-vline
WA_E1P0077_STR-RCITY sy-vline
WA_E1P0077_STR-SURPA sy-vline
WA_E1P0077_STR-RELEA sy-vline
WA_E1P0077_STR-SURSC sy-vline
WA_E1P0077_STR-ABOTY sy-vline
WA_E1P0077_STR-DTY01 sy-vline
WA_E1P0077_STR-DTY02 sy-vline
WA_E1P0077_STR-DTY03 sy-vline
WA_E1P0077_STR-DTY04 sy-vline
WA_E1P0077_STR-DTY05 sy-vline
WA_E1P0077_STR-MTY01 sy-vline
WA_E1P0077_STR-MTY02 sy-vline
WA_E1P0077_STR-MTY03 sy-vline
WA_E1P0077_STR-MTY04 sy-vline
WA_E1P0077_STR-MTY05 sy-vline
WA_E1P0077_STR-VETS1 sy-vline
WA_E1P0077_STR-VETS2 sy-vline
WA_E1P0077_STR-VETS3 sy-vline
WA_E1P0077_STR-VETS4 sy-vline
WA_E1P0077_STR-VETS5 sy-vline
WA_E1P0077_STR-VETS6 sy-vline
WA_E1P0077_STR-VETS7 sy-vline
WA_E1P0077_STR-VETS8 sy-vline
WA_E1P0077_STR-VETS9 sy-vline
WA_E1P0077_STR-VETS10 sy-vline
WA_E1P0077_STR-VETS11 sy-vline
WA_E1P0077_STR-VETS12 sy-vline
WA_E1P0077_STR-DCRDT sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.