ABAP Select data from SAP table E1P0058 into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP E1P0058 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to E1P0058. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the E1P0058 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_E1P0058 TYPE STANDARD TABLE OF E1P0058,
      WA_E1P0058 TYPE E1P0058,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <E1P0058> TYPE E1P0058.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_E1P0058.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM E1P0058
  INTO TABLE IT_E1P0058.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM E1P0058
*  INTO TABLE @DATA(IT_E1P00582).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_E1P0058 INDEX 1 INTO DATA(WA_E1P00582).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_E1P0058 ASSIGNING <E1P0058>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<E1P0058>-PERNR = 1.
<E1P0058>-INFTY = 1.
<E1P0058>-SUBTY = 1.
<E1P0058>-OBJPS = 1.
<E1P0058>-SPRPS = 1.
ENDLOOP.

LOOP AT IT_E1P0058 INTO WA_E1P0058.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_E1P0058-ENDDA, sy-vline,
WA_E1P0058-BEGDA, sy-vline,
WA_E1P0058-SEQNR, sy-vline,
WA_E1P0058-AEDTM, sy-vline,
WA_E1P0058-UNAME, sy-vline,
WA_E1P0058-HISTO, sy-vline.
ENDLOOP. *Add any further fields from structure WA_E1P0058 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_E1P0058 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_E1P0058 INTO WA_E1P0058. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_E1P0058_STR,
PERNR TYPE STRING,
INFTY TYPE STRING,
SUBTY TYPE STRING,
OBJPS TYPE STRING,
SPRPS TYPE STRING,
ENDDA TYPE STRING,
BEGDA TYPE STRING,
SEQNR TYPE STRING,
AEDTM TYPE STRING,
UNAME TYPE STRING,
HISTO TYPE STRING,
ITXEX TYPE STRING,
REFEX TYPE STRING,
ORDEX TYPE STRING,
ITBLD TYPE STRING,
PREAS TYPE STRING,
FLAG1 TYPE STRING,
FLAG2 TYPE STRING,
FLAG3 TYPE STRING,
FLAG4 TYPE STRING,
RESE1 TYPE STRING,
RESE2 TYPE STRING,
PPART TYPE STRING,
BETRG TYPE STRING,
FAHRT TYPE STRING,
HLTKM TYPE STRING,
TRNKM TYPE STRING,
OFFKM TYPE STRING,
WEGKM TYPE STRING,
WEGHR TYPE STRING,
WEGMN TYPE STRING,
DATUM TYPE STRING,
GRPVL TYPE STRING,
FWAGN TYPE STRING,
PPFKT TYPE STRING,
GPGRN TYPE STRING,
TRNK1 TYPE STRING,
TRNA1 TYPE STRING,
TRNK2 TYPE STRING,
TRNA2 TYPE STRING,
TRNK3 TYPE STRING,
TRNA3 TYPE STRING,
WEGK1 TYPE STRING,
WEGK2 TYPE STRING,
HLKMD TYPE STRING,
TRKMD TYPE STRING,
OFKMD TYPE STRING,
WRKVK TYPE STRING,
JBTKT TYPE STRING,
PRECH TYPE STRING,
TRNK1_2 TYPE STRING,
TRNK2_2 TYPE STRING,
TRNK3_2 TYPE STRING,
WEGK1_2 TYPE STRING,
WEGK2_2 TYPE STRING,END OF T_EKKO_STR. DATA: WA_E1P0058_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_E1P0058_STR-PERNR sy-vline
WA_E1P0058_STR-INFTY sy-vline
WA_E1P0058_STR-SUBTY sy-vline
WA_E1P0058_STR-OBJPS sy-vline
WA_E1P0058_STR-SPRPS sy-vline
WA_E1P0058_STR-ENDDA sy-vline
WA_E1P0058_STR-BEGDA sy-vline
WA_E1P0058_STR-SEQNR sy-vline
WA_E1P0058_STR-AEDTM sy-vline
WA_E1P0058_STR-UNAME sy-vline
WA_E1P0058_STR-HISTO sy-vline
WA_E1P0058_STR-ITXEX sy-vline
WA_E1P0058_STR-REFEX sy-vline
WA_E1P0058_STR-ORDEX sy-vline
WA_E1P0058_STR-ITBLD sy-vline
WA_E1P0058_STR-PREAS sy-vline
WA_E1P0058_STR-FLAG1 sy-vline
WA_E1P0058_STR-FLAG2 sy-vline
WA_E1P0058_STR-FLAG3 sy-vline
WA_E1P0058_STR-FLAG4 sy-vline
WA_E1P0058_STR-RESE1 sy-vline
WA_E1P0058_STR-RESE2 sy-vline
WA_E1P0058_STR-PPART sy-vline
WA_E1P0058_STR-BETRG sy-vline
WA_E1P0058_STR-FAHRT sy-vline
WA_E1P0058_STR-HLTKM sy-vline
WA_E1P0058_STR-TRNKM sy-vline
WA_E1P0058_STR-OFFKM sy-vline
WA_E1P0058_STR-WEGKM sy-vline
WA_E1P0058_STR-WEGHR sy-vline
WA_E1P0058_STR-WEGMN sy-vline
WA_E1P0058_STR-DATUM sy-vline
WA_E1P0058_STR-GRPVL sy-vline
WA_E1P0058_STR-FWAGN sy-vline
WA_E1P0058_STR-PPFKT sy-vline
WA_E1P0058_STR-GPGRN sy-vline
WA_E1P0058_STR-TRNK1 sy-vline
WA_E1P0058_STR-TRNA1 sy-vline
WA_E1P0058_STR-TRNK2 sy-vline
WA_E1P0058_STR-TRNA2 sy-vline
WA_E1P0058_STR-TRNK3 sy-vline
WA_E1P0058_STR-TRNA3 sy-vline
WA_E1P0058_STR-WEGK1 sy-vline
WA_E1P0058_STR-WEGK2 sy-vline
WA_E1P0058_STR-HLKMD sy-vline
WA_E1P0058_STR-TRKMD sy-vline
WA_E1P0058_STR-OFKMD sy-vline
WA_E1P0058_STR-WRKVK sy-vline
WA_E1P0058_STR-JBTKT sy-vline
WA_E1P0058_STR-PRECH sy-vline
WA_E1P0058_STR-TRNK1_2 sy-vline
WA_E1P0058_STR-TRNK2_2 sy-vline
WA_E1P0058_STR-TRNK3_2 sy-vline
WA_E1P0058_STR-WEGK1_2 sy-vline
WA_E1P0058_STR-WEGK2_2 sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.