ABAP Select data from SAP table E1MDPSL into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP E1MDPSL table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to E1MDPSL. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the E1MDPSL table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_E1MDPSL TYPE STANDARD TABLE OF E1MDPSL,
      WA_E1MDPSL TYPE E1MDPSL,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <E1MDPSL> TYPE E1MDPSL.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_E1MDPSL.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM E1MDPSL
  INTO TABLE IT_E1MDPSL.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM E1MDPSL
*  INTO TABLE @DATA(IT_E1MDPSL2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_E1MDPSL INDEX 1 INTO DATA(WA_E1MDPSL2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_E1MDPSL ASSIGNING <E1MDPSL>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<E1MDPSL>-AUFVR = 1.
<E1MDPSL>-BAUGR = 1.
<E1MDPSL>-BESKZ = 1.
<E1MDPSL>-DAT00 = 1.
<E1MDPSL>-DAT01 = 1.
ENDLOOP.

LOOP AT IT_E1MDPSL INTO WA_E1MDPSL.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_E1MDPSL-DAT02, sy-vline,
WA_E1MDPSL-DEL12, sy-vline,
WA_E1MDPSL-DELKZ, sy-vline,
WA_E1MDPSL-DELET, sy-vline,
WA_E1MDPSL-DELNR, sy-vline,
WA_E1MDPSL-DELPS, sy-vline.
ENDLOOP. *Add any further fields from structure WA_E1MDPSL you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_E1MDPSL TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_E1MDPSL INTO WA_E1MDPSL. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit MATN5, internal->external for field BAUGR CALL FUNCTION 'CONVERSION_EXIT_MATN5_OUTPUT' EXPORTING input = WA_E1MDPSL-BAUGR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_E1MDPSL-BAUGR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field KDAUF CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_E1MDPSL-KDAUF IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_E1MDPSL-KDAUF.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field KUNNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_E1MDPSL-KUNNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_E1MDPSL-KUNNR.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_E1MDPSL_STR,
AUFVR TYPE STRING,
BAUGR TYPE STRING,
BESKZ TYPE STRING,
DAT00 TYPE STRING,
DAT01 TYPE STRING,
DAT02 TYPE STRING,
DEL12 TYPE STRING,
DELKZ TYPE STRING,
DELET TYPE STRING,
DELNR TYPE STRING,
DELPS TYPE STRING,
EINVR TYPE STRING,
KDAUF TYPE STRING,
KDPOS TYPE STRING,
LGORT TYPE STRING,
MNG01 TYPE STRING,
MNG02 TYPE STRING,
PLUMI TYPE STRING,
POSVR TYPE STRING,
PSPEL TYPE STRING,
SOBES TYPE STRING,
VERID TYPE STRING,
VRFKZ TYPE STRING,
WEBAZ TYPE STRING,
WRK02 TYPE STRING,
KUNNR TYPE STRING,
AUART TYPE STRING,
FIX01 TYPE STRING,
BAART TYPE STRING,
BAUGR_EXTERNAL TYPE STRING,
BAUGR_VERSION TYPE STRING,
BAUGR_GUID TYPE STRING,
BAUGR_LONG TYPE STRING,END OF T_EKKO_STR. DATA: WA_E1MDPSL_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_E1MDPSL_STR-AUFVR sy-vline
WA_E1MDPSL_STR-BAUGR sy-vline
WA_E1MDPSL_STR-BESKZ sy-vline
WA_E1MDPSL_STR-DAT00 sy-vline
WA_E1MDPSL_STR-DAT01 sy-vline
WA_E1MDPSL_STR-DAT02 sy-vline
WA_E1MDPSL_STR-DEL12 sy-vline
WA_E1MDPSL_STR-DELKZ sy-vline
WA_E1MDPSL_STR-DELET sy-vline
WA_E1MDPSL_STR-DELNR sy-vline
WA_E1MDPSL_STR-DELPS sy-vline
WA_E1MDPSL_STR-EINVR sy-vline
WA_E1MDPSL_STR-KDAUF sy-vline
WA_E1MDPSL_STR-KDPOS sy-vline
WA_E1MDPSL_STR-LGORT sy-vline
WA_E1MDPSL_STR-MNG01 sy-vline
WA_E1MDPSL_STR-MNG02 sy-vline
WA_E1MDPSL_STR-PLUMI sy-vline
WA_E1MDPSL_STR-POSVR sy-vline
WA_E1MDPSL_STR-PSPEL sy-vline
WA_E1MDPSL_STR-SOBES sy-vline
WA_E1MDPSL_STR-VERID sy-vline
WA_E1MDPSL_STR-VRFKZ sy-vline
WA_E1MDPSL_STR-WEBAZ sy-vline
WA_E1MDPSL_STR-WRK02 sy-vline
WA_E1MDPSL_STR-KUNNR sy-vline
WA_E1MDPSL_STR-AUART sy-vline
WA_E1MDPSL_STR-FIX01 sy-vline
WA_E1MDPSL_STR-BAART sy-vline
WA_E1MDPSL_STR-BAUGR_EXTERNAL sy-vline
WA_E1MDPSL_STR-BAUGR_VERSION sy-vline
WA_E1MDPSL_STR-BAUGR_GUID sy-vline
WA_E1MDPSL_STR-BAUGR_LONG sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.