ABAP Select data from SAP table E1MBEWM into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP E1MBEWM table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to E1MBEWM. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the E1MBEWM table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_E1MBEWM TYPE STANDARD TABLE OF E1MBEWM,
      WA_E1MBEWM TYPE E1MBEWM,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <E1MBEWM> TYPE E1MBEWM.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_E1MBEWM.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM E1MBEWM
  INTO TABLE IT_E1MBEWM.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM E1MBEWM
*  INTO TABLE @DATA(IT_E1MBEWM2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_E1MBEWM INDEX 1 INTO DATA(WA_E1MBEWM2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_E1MBEWM ASSIGNING <E1MBEWM>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<E1MBEWM>-MSGFN = 1.
<E1MBEWM>-BWKEY = 1.
<E1MBEWM>-BWTAR = 1.
<E1MBEWM>-LVORM = 1.
<E1MBEWM>-VPRSV = 1.
ENDLOOP.

LOOP AT IT_E1MBEWM INTO WA_E1MBEWM.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_E1MBEWM-VERPR, sy-vline,
WA_E1MBEWM-STPRS, sy-vline,
WA_E1MBEWM-PEINH, sy-vline,
WA_E1MBEWM-BKLAS, sy-vline,
WA_E1MBEWM-VMVPR, sy-vline,
WA_E1MBEWM-VMVER, sy-vline.
ENDLOOP. *Add any further fields from structure WA_E1MBEWM you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_E1MBEWM TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_E1MBEWM INTO WA_E1MBEWM. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_E1MBEWM_STR,
MSGFN TYPE STRING,
BWKEY TYPE STRING,
BWTAR TYPE STRING,
LVORM TYPE STRING,
VPRSV TYPE STRING,
VERPR TYPE STRING,
STPRS TYPE STRING,
PEINH TYPE STRING,
BKLAS TYPE STRING,
VMVPR TYPE STRING,
VMVER TYPE STRING,
VMSTP TYPE STRING,
VMPEI TYPE STRING,
VMBKL TYPE STRING,
VJVPR TYPE STRING,
VJVER TYPE STRING,
VJSTP TYPE STRING,
LFGJA TYPE STRING,
LFMON TYPE STRING,
BWTTY TYPE STRING,
ZKPRS TYPE STRING,
ZKDAT TYPE STRING,
BWPRS TYPE STRING,
BWPRH TYPE STRING,
VJBWS TYPE STRING,
VJBWH TYPE STRING,
VVJLB TYPE STRING,
VVMLB TYPE STRING,
VVSAL TYPE STRING,
ZPLPR TYPE STRING,
ZPLP1 TYPE STRING,
ZPLP2 TYPE STRING,
ZPLP3 TYPE STRING,
ZPLD1 TYPE STRING,
ZPLD2 TYPE STRING,
ZPLD3 TYPE STRING,
KALKZ TYPE STRING,
KALKL TYPE STRING,
XLIFO TYPE STRING,
MYPOL TYPE STRING,
BWPH1 TYPE STRING,
BWPS1 TYPE STRING,
ABWKZ TYPE STRING,
PSTAT TYPE STRING,
KALN1 TYPE STRING,
KALNR TYPE STRING,
BWVA1 TYPE STRING,
BWVA2 TYPE STRING,
BWVA3 TYPE STRING,
VERS1 TYPE STRING,
VERS2 TYPE STRING,
VERS3 TYPE STRING,
HRKFT TYPE STRING,
KOSGR TYPE STRING,
PPRDZ TYPE STRING,
PPRDL TYPE STRING,
PPRDV TYPE STRING,
PDATZ TYPE STRING,
PDATL TYPE STRING,
PDATV TYPE STRING,
EKALR TYPE STRING,
VPLPR TYPE STRING,
MLMAA TYPE STRING,
MLAST TYPE STRING,
VJBKL TYPE STRING,
VJPEI TYPE STRING,
HKMAT TYPE STRING,
EKLAS TYPE STRING,
QKLAS TYPE STRING,
MTUSE TYPE STRING,
MTORG TYPE STRING,
OWNPR TYPE STRING,
BWPEI TYPE STRING,
CON_FIN_VALLEVEL TYPE STRING,
CON_FIN_VALPROC TYPE STRING,END OF T_EKKO_STR. DATA: WA_E1MBEWM_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_E1MBEWM_STR-MSGFN sy-vline
WA_E1MBEWM_STR-BWKEY sy-vline
WA_E1MBEWM_STR-BWTAR sy-vline
WA_E1MBEWM_STR-LVORM sy-vline
WA_E1MBEWM_STR-VPRSV sy-vline
WA_E1MBEWM_STR-VERPR sy-vline
WA_E1MBEWM_STR-STPRS sy-vline
WA_E1MBEWM_STR-PEINH sy-vline
WA_E1MBEWM_STR-BKLAS sy-vline
WA_E1MBEWM_STR-VMVPR sy-vline
WA_E1MBEWM_STR-VMVER sy-vline
WA_E1MBEWM_STR-VMSTP sy-vline
WA_E1MBEWM_STR-VMPEI sy-vline
WA_E1MBEWM_STR-VMBKL sy-vline
WA_E1MBEWM_STR-VJVPR sy-vline
WA_E1MBEWM_STR-VJVER sy-vline
WA_E1MBEWM_STR-VJSTP sy-vline
WA_E1MBEWM_STR-LFGJA sy-vline
WA_E1MBEWM_STR-LFMON sy-vline
WA_E1MBEWM_STR-BWTTY sy-vline
WA_E1MBEWM_STR-ZKPRS sy-vline
WA_E1MBEWM_STR-ZKDAT sy-vline
WA_E1MBEWM_STR-BWPRS sy-vline
WA_E1MBEWM_STR-BWPRH sy-vline
WA_E1MBEWM_STR-VJBWS sy-vline
WA_E1MBEWM_STR-VJBWH sy-vline
WA_E1MBEWM_STR-VVJLB sy-vline
WA_E1MBEWM_STR-VVMLB sy-vline
WA_E1MBEWM_STR-VVSAL sy-vline
WA_E1MBEWM_STR-ZPLPR sy-vline
WA_E1MBEWM_STR-ZPLP1 sy-vline
WA_E1MBEWM_STR-ZPLP2 sy-vline
WA_E1MBEWM_STR-ZPLP3 sy-vline
WA_E1MBEWM_STR-ZPLD1 sy-vline
WA_E1MBEWM_STR-ZPLD2 sy-vline
WA_E1MBEWM_STR-ZPLD3 sy-vline
WA_E1MBEWM_STR-KALKZ sy-vline
WA_E1MBEWM_STR-KALKL sy-vline
WA_E1MBEWM_STR-XLIFO sy-vline
WA_E1MBEWM_STR-MYPOL sy-vline
WA_E1MBEWM_STR-BWPH1 sy-vline
WA_E1MBEWM_STR-BWPS1 sy-vline
WA_E1MBEWM_STR-ABWKZ sy-vline
WA_E1MBEWM_STR-PSTAT sy-vline
WA_E1MBEWM_STR-KALN1 sy-vline
WA_E1MBEWM_STR-KALNR sy-vline
WA_E1MBEWM_STR-BWVA1 sy-vline
WA_E1MBEWM_STR-BWVA2 sy-vline
WA_E1MBEWM_STR-BWVA3 sy-vline
WA_E1MBEWM_STR-VERS1 sy-vline
WA_E1MBEWM_STR-VERS2 sy-vline
WA_E1MBEWM_STR-VERS3 sy-vline
WA_E1MBEWM_STR-HRKFT sy-vline
WA_E1MBEWM_STR-KOSGR sy-vline
WA_E1MBEWM_STR-PPRDZ sy-vline
WA_E1MBEWM_STR-PPRDL sy-vline
WA_E1MBEWM_STR-PPRDV sy-vline
WA_E1MBEWM_STR-PDATZ sy-vline
WA_E1MBEWM_STR-PDATL sy-vline
WA_E1MBEWM_STR-PDATV sy-vline
WA_E1MBEWM_STR-EKALR sy-vline
WA_E1MBEWM_STR-VPLPR sy-vline
WA_E1MBEWM_STR-MLMAA sy-vline
WA_E1MBEWM_STR-MLAST sy-vline
WA_E1MBEWM_STR-VJBKL sy-vline
WA_E1MBEWM_STR-VJPEI sy-vline
WA_E1MBEWM_STR-HKMAT sy-vline
WA_E1MBEWM_STR-EKLAS sy-vline
WA_E1MBEWM_STR-QKLAS sy-vline
WA_E1MBEWM_STR-MTUSE sy-vline
WA_E1MBEWM_STR-MTORG sy-vline
WA_E1MBEWM_STR-OWNPR sy-vline
WA_E1MBEWM_STR-BWPEI sy-vline
WA_E1MBEWM_STR-CON_FIN_VALLEVEL sy-vline
WA_E1MBEWM_STR-CON_FIN_VALPROC sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.