ABAP Select data from SAP table E1ISU_PPM_QS05 into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP E1ISU_PPM_QS05 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to E1ISU_PPM_QS05. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the E1ISU_PPM_QS05 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_E1ISU_PPM_QS05 TYPE STANDARD TABLE OF E1ISU_PPM_QS05,
      WA_E1ISU_PPM_QS05 TYPE E1ISU_PPM_QS05,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <E1ISU_PPM_QS05> TYPE E1ISU_PPM_QS05.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_E1ISU_PPM_QS05.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM E1ISU_PPM_QS05
  INTO TABLE IT_E1ISU_PPM_QS05.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM E1ISU_PPM_QS05
*  INTO TABLE @DATA(IT_E1ISU_PPM_QS052).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_E1ISU_PPM_QS05 INDEX 1 INTO DATA(WA_E1ISU_PPM_QS052).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_E1ISU_PPM_QS05 ASSIGNING <E1ISU_PPM_QS05>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<E1ISU_PPM_QS05>-JOB_TYP = 1.
<E1ISU_PPM_QS05>-JOB_NR = 1.
<E1ISU_PPM_QS05>-VERTRAG = 1.
<E1ISU_PPM_QS05>-METER_POSTCODE = 1.
<E1ISU_PPM_QS05>-METER_POINT_REF = 1.
ENDLOOP.

LOOP AT IT_E1ISU_PPM_QS05 INTO WA_E1ISU_PPM_QS05.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_E1ISU_PPM_QS05-ISSUE_TYPE, sy-vline,
WA_E1ISU_PPM_QS05-EM_INDICATOR, sy-vline,
WA_E1ISU_PPM_QS05-CARD_ISSUE, sy-vline,
WA_E1ISU_PPM_QS05-CHARGING_STATUS, sy-vline,
WA_E1ISU_PPM_QS05-PARTNER, sy-vline,
WA_E1ISU_PPM_QS05-NAME_LAST, sy-vline.
ENDLOOP. *Add any further fields from structure WA_E1ISU_PPM_QS05 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_E1ISU_PPM_QS05 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_E1ISU_PPM_QS05 INTO WA_E1ISU_PPM_QS05. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_E1ISU_PPM_QS05_STR,
JOB_TYP TYPE STRING,
JOB_NR TYPE STRING,
VERTRAG TYPE STRING,
METER_POSTCODE TYPE STRING,
METER_POINT_REF TYPE STRING,
ISSUE_TYPE TYPE STRING,
EM_INDICATOR TYPE STRING,
CARD_ISSUE TYPE STRING,
CHARGING_STATUS TYPE STRING,
PARTNER TYPE STRING,
NAME_LAST TYPE STRING,
NAME_FIRST TYPE STRING,
NAME_ORG1 TYPE STRING,
NAME_ORG2 TYPE STRING,
NAME_ORG3 TYPE STRING,
NAME_ORG4 TYPE STRING,
NAME_GRP1 TYPE STRING,
NAME_GRP2 TYPE STRING,
POST_CODE1 TYPE STRING,
CITY2 TYPE STRING,
CITY1 TYPE STRING,
REGION TYPE STRING,
STREET TYPE STRING,
STR_SUPPL1 TYPE STRING,
STR_SUPPL2 TYPE STRING,
STR_SUPPL3 TYPE STRING,
LOCATION TYPE STRING,
HOUSE_NUM1 TYPE STRING,
HOUSE_NUM2 TYPE STRING,
HOUSE_NUM3 TYPE STRING,
NDG_INDICATOR TYPE STRING,
NDG_ADJUSTMENT TYPE STRING,
NDG_RATE TYPE STRING,
NDG_WEEKLY_MIN TYPE STRING,
NDG_WEEKLY_MAX TYPE STRING,
GAS_ALLOCA_RATE TYPE STRING,
GAS_INDICATOR TYPE STRING,
GAS_ADJUSTMENT TYPE STRING,
GAS_RATE TYPE STRING,
GAS_WEEKLY_MIN TYPE STRING,
GAS_WEEKLY_MAX TYPE STRING,
CREDIT_INDICATOR TYPE STRING,
CREDIT_ADJUSTMENT TYPE STRING,
OUTLETID_1 TYPE STRING,
OUTLETID_2 TYPE STRING,
CONTACT_NAME TYPE STRING,
CONTACT_PHONE TYPE STRING,
REQUEST_DATE TYPE STRING,
TWAERS TYPE STRING,
ISOCD TYPE STRING,
NUMBER_MESSAGE TYPE STRING,END OF T_EKKO_STR. DATA: WA_E1ISU_PPM_QS05_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_E1ISU_PPM_QS05_STR-JOB_TYP sy-vline
WA_E1ISU_PPM_QS05_STR-JOB_NR sy-vline
WA_E1ISU_PPM_QS05_STR-VERTRAG sy-vline
WA_E1ISU_PPM_QS05_STR-METER_POSTCODE sy-vline
WA_E1ISU_PPM_QS05_STR-METER_POINT_REF sy-vline
WA_E1ISU_PPM_QS05_STR-ISSUE_TYPE sy-vline
WA_E1ISU_PPM_QS05_STR-EM_INDICATOR sy-vline
WA_E1ISU_PPM_QS05_STR-CARD_ISSUE sy-vline
WA_E1ISU_PPM_QS05_STR-CHARGING_STATUS sy-vline
WA_E1ISU_PPM_QS05_STR-PARTNER sy-vline
WA_E1ISU_PPM_QS05_STR-NAME_LAST sy-vline
WA_E1ISU_PPM_QS05_STR-NAME_FIRST sy-vline
WA_E1ISU_PPM_QS05_STR-NAME_ORG1 sy-vline
WA_E1ISU_PPM_QS05_STR-NAME_ORG2 sy-vline
WA_E1ISU_PPM_QS05_STR-NAME_ORG3 sy-vline
WA_E1ISU_PPM_QS05_STR-NAME_ORG4 sy-vline
WA_E1ISU_PPM_QS05_STR-NAME_GRP1 sy-vline
WA_E1ISU_PPM_QS05_STR-NAME_GRP2 sy-vline
WA_E1ISU_PPM_QS05_STR-POST_CODE1 sy-vline
WA_E1ISU_PPM_QS05_STR-CITY2 sy-vline
WA_E1ISU_PPM_QS05_STR-CITY1 sy-vline
WA_E1ISU_PPM_QS05_STR-REGION sy-vline
WA_E1ISU_PPM_QS05_STR-STREET sy-vline
WA_E1ISU_PPM_QS05_STR-STR_SUPPL1 sy-vline
WA_E1ISU_PPM_QS05_STR-STR_SUPPL2 sy-vline
WA_E1ISU_PPM_QS05_STR-STR_SUPPL3 sy-vline
WA_E1ISU_PPM_QS05_STR-LOCATION sy-vline
WA_E1ISU_PPM_QS05_STR-HOUSE_NUM1 sy-vline
WA_E1ISU_PPM_QS05_STR-HOUSE_NUM2 sy-vline
WA_E1ISU_PPM_QS05_STR-HOUSE_NUM3 sy-vline
WA_E1ISU_PPM_QS05_STR-NDG_INDICATOR sy-vline
WA_E1ISU_PPM_QS05_STR-NDG_ADJUSTMENT sy-vline
WA_E1ISU_PPM_QS05_STR-NDG_RATE sy-vline
WA_E1ISU_PPM_QS05_STR-NDG_WEEKLY_MIN sy-vline
WA_E1ISU_PPM_QS05_STR-NDG_WEEKLY_MAX sy-vline
WA_E1ISU_PPM_QS05_STR-GAS_ALLOCA_RATE sy-vline
WA_E1ISU_PPM_QS05_STR-GAS_INDICATOR sy-vline
WA_E1ISU_PPM_QS05_STR-GAS_ADJUSTMENT sy-vline
WA_E1ISU_PPM_QS05_STR-GAS_RATE sy-vline
WA_E1ISU_PPM_QS05_STR-GAS_WEEKLY_MIN sy-vline
WA_E1ISU_PPM_QS05_STR-GAS_WEEKLY_MAX sy-vline
WA_E1ISU_PPM_QS05_STR-CREDIT_INDICATOR sy-vline
WA_E1ISU_PPM_QS05_STR-CREDIT_ADJUSTMENT sy-vline
WA_E1ISU_PPM_QS05_STR-OUTLETID_1 sy-vline
WA_E1ISU_PPM_QS05_STR-OUTLETID_2 sy-vline
WA_E1ISU_PPM_QS05_STR-CONTACT_NAME sy-vline
WA_E1ISU_PPM_QS05_STR-CONTACT_PHONE sy-vline
WA_E1ISU_PPM_QS05_STR-REQUEST_DATE sy-vline
WA_E1ISU_PPM_QS05_STR-TWAERS sy-vline
WA_E1ISU_PPM_QS05_STR-ISOCD sy-vline
WA_E1ISU_PPM_QS05_STR-NUMBER_MESSAGE sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.