ABAP Select data from SAP table E1FVBUP into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP E1FVBUP table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to E1FVBUP. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the E1FVBUP table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_E1FVBUP TYPE STANDARD TABLE OF E1FVBUP,
      WA_E1FVBUP TYPE E1FVBUP,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <E1FVBUP> TYPE E1FVBUP.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_E1FVBUP.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM E1FVBUP
  INTO TABLE IT_E1FVBUP.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM E1FVBUP
*  INTO TABLE @DATA(IT_E1FVBUP2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_E1FVBUP INDEX 1 INTO DATA(WA_E1FVBUP2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_E1FVBUP ASSIGNING <E1FVBUP>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<E1FVBUP>-SUPKZ = 1.
<E1FVBUP>-VBELN = 1.
<E1FVBUP>-POSNR = 1.
<E1FVBUP>-RFSTA = 1.
<E1FVBUP>-RFGSA = 1.
ENDLOOP.

LOOP AT IT_E1FVBUP INTO WA_E1FVBUP.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_E1FVBUP-BESTA, sy-vline,
WA_E1FVBUP-LFSTA, sy-vline,
WA_E1FVBUP-LFGSA, sy-vline,
WA_E1FVBUP-WBSTA, sy-vline,
WA_E1FVBUP-FKSTA, sy-vline,
WA_E1FVBUP-FKSAA, sy-vline.
ENDLOOP. *Add any further fields from structure WA_E1FVBUP you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_E1FVBUP TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_E1FVBUP INTO WA_E1FVBUP. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_E1FVBUP_STR,
SUPKZ TYPE STRING,
VBELN TYPE STRING,
POSNR TYPE STRING,
RFSTA TYPE STRING,
RFGSA TYPE STRING,
BESTA TYPE STRING,
LFSTA TYPE STRING,
LFGSA TYPE STRING,
WBSTA TYPE STRING,
FKSTA TYPE STRING,
FKSAA TYPE STRING,
ABSTA TYPE STRING,
GBSTA TYPE STRING,
KOSTA TYPE STRING,
LVSTA TYPE STRING,
UVALL TYPE STRING,
UVVLK TYPE STRING,
UVFAK TYPE STRING,
UVPRS TYPE STRING,
FKIVP TYPE STRING,
UVP01 TYPE STRING,
UVP02 TYPE STRING,
UVP03 TYPE STRING,
UVP04 TYPE STRING,
UVP05 TYPE STRING,
PKSTA TYPE STRING,
KOQUA TYPE STRING,
COSTA TYPE STRING,END OF T_EKKO_STR. DATA: WA_E1FVBUP_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_E1FVBUP_STR-SUPKZ sy-vline
WA_E1FVBUP_STR-VBELN sy-vline
WA_E1FVBUP_STR-POSNR sy-vline
WA_E1FVBUP_STR-RFSTA sy-vline
WA_E1FVBUP_STR-RFGSA sy-vline
WA_E1FVBUP_STR-BESTA sy-vline
WA_E1FVBUP_STR-LFSTA sy-vline
WA_E1FVBUP_STR-LFGSA sy-vline
WA_E1FVBUP_STR-WBSTA sy-vline
WA_E1FVBUP_STR-FKSTA sy-vline
WA_E1FVBUP_STR-FKSAA sy-vline
WA_E1FVBUP_STR-ABSTA sy-vline
WA_E1FVBUP_STR-GBSTA sy-vline
WA_E1FVBUP_STR-KOSTA sy-vline
WA_E1FVBUP_STR-LVSTA sy-vline
WA_E1FVBUP_STR-UVALL sy-vline
WA_E1FVBUP_STR-UVVLK sy-vline
WA_E1FVBUP_STR-UVFAK sy-vline
WA_E1FVBUP_STR-UVPRS sy-vline
WA_E1FVBUP_STR-FKIVP sy-vline
WA_E1FVBUP_STR-UVP01 sy-vline
WA_E1FVBUP_STR-UVP02 sy-vline
WA_E1FVBUP_STR-UVP03 sy-vline
WA_E1FVBUP_STR-UVP04 sy-vline
WA_E1FVBUP_STR-UVP05 sy-vline
WA_E1FVBUP_STR-PKSTA sy-vline
WA_E1FVBUP_STR-KOQUA sy-vline
WA_E1FVBUP_STR-COSTA sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.