ABAP Select data from SAP table E1FPLTF into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP E1FPLTF table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to E1FPLTF. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the E1FPLTF table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_E1FPLTF TYPE STANDARD TABLE OF E1FPLTF,
      WA_E1FPLTF TYPE E1FPLTF,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <E1FPLTF> TYPE E1FPLTF.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_E1FPLTF.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM E1FPLTF
  INTO TABLE IT_E1FPLTF.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM E1FPLTF
*  INTO TABLE @DATA(IT_E1FPLTF2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_E1FPLTF INDEX 1 INTO DATA(WA_E1FPLTF2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_E1FPLTF ASSIGNING <E1FPLTF>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<E1FPLTF>-SUPKZ = 1.
<E1FPLTF>-FPLNR = 1.
<E1FPLTF>-FPLTR = 1.
<E1FPLTF>-FPTTP = 1.
<E1FPLTF>-TETXT = 1.
ENDLOOP.

LOOP AT IT_E1FPLTF INTO WA_E1FPLTF.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_E1FPLTF-FKDAT, sy-vline,
WA_E1FPLTF-FPFIX, sy-vline,
WA_E1FPLTF-FAREG, sy-vline,
WA_E1FPLTF-FPROZ, sy-vline,
WA_E1FPLTF-WAERS, sy-vline,
WA_E1FPLTF-KURFP, sy-vline.
ENDLOOP. *Add any further fields from structure WA_E1FPLTF you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_E1FPLTF TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_E1FPLTF INTO WA_E1FPLTF. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_E1FPLTF_STR,
SUPKZ TYPE STRING,
FPLNR TYPE STRING,
FPLTR TYPE STRING,
FPTTP TYPE STRING,
TETXT TYPE STRING,
FKDAT TYPE STRING,
FPFIX TYPE STRING,
FAREG TYPE STRING,
FPROZ TYPE STRING,
WAERS TYPE STRING,
KURFP TYPE STRING,
FAKWR TYPE STRING,
FAKSP TYPE STRING,
FKARV TYPE STRING,
FKSAF TYPE STRING,
PERIO TYPE STRING,
FPLAE TYPE STRING,
MLSTN TYPE STRING,
MLBEZ TYPE STRING,
ZTERM TYPE STRING,
KUNRG TYPE STRING,
TAXK1 TYPE STRING,
TAXK2 TYPE STRING,
TAXK3 TYPE STRING,
TAXK4 TYPE STRING,
TAXK5 TYPE STRING,
TAXK6 TYPE STRING,
TAXK7 TYPE STRING,
TAXK8 TYPE STRING,
TAXK9 TYPE STRING,
VALTG TYPE STRING,
VALDT TYPE STRING,
NFDAT TYPE STRING,END OF T_EKKO_STR. DATA: WA_E1FPLTF_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_E1FPLTF_STR-SUPKZ sy-vline
WA_E1FPLTF_STR-FPLNR sy-vline
WA_E1FPLTF_STR-FPLTR sy-vline
WA_E1FPLTF_STR-FPTTP sy-vline
WA_E1FPLTF_STR-TETXT sy-vline
WA_E1FPLTF_STR-FKDAT sy-vline
WA_E1FPLTF_STR-FPFIX sy-vline
WA_E1FPLTF_STR-FAREG sy-vline
WA_E1FPLTF_STR-FPROZ sy-vline
WA_E1FPLTF_STR-WAERS sy-vline
WA_E1FPLTF_STR-KURFP sy-vline
WA_E1FPLTF_STR-FAKWR sy-vline
WA_E1FPLTF_STR-FAKSP sy-vline
WA_E1FPLTF_STR-FKARV sy-vline
WA_E1FPLTF_STR-FKSAF sy-vline
WA_E1FPLTF_STR-PERIO sy-vline
WA_E1FPLTF_STR-FPLAE sy-vline
WA_E1FPLTF_STR-MLSTN sy-vline
WA_E1FPLTF_STR-MLBEZ sy-vline
WA_E1FPLTF_STR-ZTERM sy-vline
WA_E1FPLTF_STR-KUNRG sy-vline
WA_E1FPLTF_STR-TAXK1 sy-vline
WA_E1FPLTF_STR-TAXK2 sy-vline
WA_E1FPLTF_STR-TAXK3 sy-vline
WA_E1FPLTF_STR-TAXK4 sy-vline
WA_E1FPLTF_STR-TAXK5 sy-vline
WA_E1FPLTF_STR-TAXK6 sy-vline
WA_E1FPLTF_STR-TAXK7 sy-vline
WA_E1FPLTF_STR-TAXK8 sy-vline
WA_E1FPLTF_STR-TAXK9 sy-vline
WA_E1FPLTF_STR-VALTG sy-vline
WA_E1FPLTF_STR-VALDT sy-vline
WA_E1FPLTF_STR-NFDAT sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.