ABAP Select data from SAP table E1FIPRP into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP E1FIPRP table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to E1FIPRP. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the E1FIPRP table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_E1FIPRP TYPE STANDARD TABLE OF E1FIPRP,
      WA_E1FIPRP TYPE E1FIPRP,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <E1FIPRP> TYPE E1FIPRP.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_E1FIPRP.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM E1FIPRP
  INTO TABLE IT_E1FIPRP.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM E1FIPRP
*  INTO TABLE @DATA(IT_E1FIPRP2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_E1FIPRP INDEX 1 INTO DATA(WA_E1FIPRP2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_E1FIPRP ASSIGNING <E1FIPRP>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<E1FIPRP>-GPART_TYP = 1.
<E1FIPRP>-ANRED = 1.
<E1FIPRP>-NAME1 = 1.
<E1FIPRP>-NAME2 = 1.
<E1FIPRP>-NAME3 = 1.
ENDLOOP.

LOOP AT IT_E1FIPRP INTO WA_E1FIPRP.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_E1FIPRP-NAME4, sy-vline,
WA_E1FIPRP-LAND1, sy-vline,
WA_E1FIPRP-REGIO, sy-vline,
WA_E1FIPRP-PSTLZ, sy-vline,
WA_E1FIPRP-ORT01, sy-vline,
WA_E1FIPRP-ORT02, sy-vline.
ENDLOOP. *Add any further fields from structure WA_E1FIPRP you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_E1FIPRP TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_E1FIPRP INTO WA_E1FIPRP. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_E1FIPRP_STR,
GPART_TYP TYPE STRING,
ANRED TYPE STRING,
NAME1 TYPE STRING,
NAME2 TYPE STRING,
NAME3 TYPE STRING,
NAME4 TYPE STRING,
LAND1 TYPE STRING,
REGIO TYPE STRING,
PSTLZ TYPE STRING,
ORT01 TYPE STRING,
ORT02 TYPE STRING,
STRAS TYPE STRING,
HSNM1 TYPE STRING,
HSNM2 TYPE STRING,
LAND2 TYPE STRING,
ORTPF TYPE STRING,
PSTL2 TYPE STRING,
PFACH TYPE STRING,
PSTL3 TYPE STRING,
BUSAB TYPE STRING,
STCD1 TYPE STRING,
SPRAS TYPE STRING,
EIKTO TYPE STRING,
TLFX1 TYPE STRING,
TLFX2 TYPE STRING,
TELF1 TYPE STRING,
TELF2 TYPE STRING,
TELX1 TYPE STRING,END OF T_EKKO_STR. DATA: WA_E1FIPRP_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_E1FIPRP_STR-GPART_TYP sy-vline
WA_E1FIPRP_STR-ANRED sy-vline
WA_E1FIPRP_STR-NAME1 sy-vline
WA_E1FIPRP_STR-NAME2 sy-vline
WA_E1FIPRP_STR-NAME3 sy-vline
WA_E1FIPRP_STR-NAME4 sy-vline
WA_E1FIPRP_STR-LAND1 sy-vline
WA_E1FIPRP_STR-REGIO sy-vline
WA_E1FIPRP_STR-PSTLZ sy-vline
WA_E1FIPRP_STR-ORT01 sy-vline
WA_E1FIPRP_STR-ORT02 sy-vline
WA_E1FIPRP_STR-STRAS sy-vline
WA_E1FIPRP_STR-HSNM1 sy-vline
WA_E1FIPRP_STR-HSNM2 sy-vline
WA_E1FIPRP_STR-LAND2 sy-vline
WA_E1FIPRP_STR-ORTPF sy-vline
WA_E1FIPRP_STR-PSTL2 sy-vline
WA_E1FIPRP_STR-PFACH sy-vline
WA_E1FIPRP_STR-PSTL3 sy-vline
WA_E1FIPRP_STR-BUSAB sy-vline
WA_E1FIPRP_STR-STCD1 sy-vline
WA_E1FIPRP_STR-SPRAS sy-vline
WA_E1FIPRP_STR-EIKTO sy-vline
WA_E1FIPRP_STR-TLFX1 sy-vline
WA_E1FIPRP_STR-TLFX2 sy-vline
WA_E1FIPRP_STR-TELF1 sy-vline
WA_E1FIPRP_STR-TELF2 sy-vline
WA_E1FIPRP_STR-TELX1 sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.