ABAP Select data from SAP table E1EVMEEM into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP E1EVMEEM table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to E1EVMEEM. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the E1EVMEEM table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_E1EVMEEM TYPE STANDARD TABLE OF E1EVMEEM,
      WA_E1EVMEEM TYPE E1EVMEEM,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <E1EVMEEM> TYPE E1EVMEEM.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_E1EVMEEM.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM E1EVMEEM
  INTO TABLE IT_E1EVMEEM.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM E1EVMEEM
*  INTO TABLE @DATA(IT_E1EVMEEM2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_E1EVMEEM INDEX 1 INTO DATA(WA_E1EVMEEM2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_E1EVMEEM ASSIGNING <E1EVMEEM>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<E1EVMEEM>-MODCNT = 1.
<E1EVMEEM>-EVTCOD = 1.
<E1EVMEEM>-EVTID = 1.
<E1EVMEEM>-EVTACT = 1.
<E1EVMEEM>-MODREF = 1.
ENDLOOP.

LOOP AT IT_E1EVMEEM INTO WA_E1EVMEEM.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_E1EVMEEM-ESTATT, sy-vline,
WA_E1EVMEEM-LOCCOD, sy-vline,
WA_E1EVMEEM-LOCID1, sy-vline,
WA_E1EVMEEM-LOCID2, sy-vline,
WA_E1EVMEEM-LOCNAM, sy-vline,
WA_E1EVMEEM-LOCZON, sy-vline.
ENDLOOP. *Add any further fields from structure WA_E1EVMEEM you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_E1EVMEEM TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_E1EVMEEM INTO WA_E1EVMEEM. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_E1EVMEEM_STR,
MODCNT TYPE STRING,
EVTCOD TYPE STRING,
EVTID TYPE STRING,
EVTACT TYPE STRING,
MODREF TYPE STRING,
ESTATT TYPE STRING,
LOCCOD TYPE STRING,
LOCID1 TYPE STRING,
LOCID2 TYPE STRING,
LOCNAM TYPE STRING,
LOCZON TYPE STRING,
PARCOD TYPE STRING,
PARID TYPE STRING,
PARNAM TYPE STRING,
LANGUAGE TYPE STRING,
CRCCOD TYPE STRING,
CRCID TYPE STRING,
CHRTX TYPE STRING,
ETADUR TYPE STRING,
ETXDAT TYPE STRING,
ETXTIM TYPE STRING,
ETXZON TYPE STRING,
ETEADT TYPE STRING,
ETEATI TYPE STRING,
ETLTDT TYPE STRING,
ETLTTI TYPE STRING,
MSGDUR TYPE STRING,
MSGDAT TYPE STRING,
MSGTIM TYPE STRING,
MSGZON TYPE STRING,
MSEADT TYPE STRING,
MSEATI TYPE STRING,
MSLTDT TYPE STRING,
MSLTTI TYPE STRING,
DATE1 TYPE STRING,
TIME1 TYPE STRING,
TZONE1 TYPE STRING,
DATE2 TYPE STRING,
TIME2 TYPE STRING,
TZONE2 TYPE STRING,
DATE3 TYPE STRING,
TIME3 TYPE STRING,
TZONE3 TYPE STRING,
DATE4 TYPE STRING,
TIME4 TYPE STRING,
TZONE4 TYPE STRING,
DATE5 TYPE STRING,
TIME5 TYPE STRING,
TZONE5 TYPE STRING,
DATACS TYPE STRING,
DATAID TYPE STRING,END OF T_EKKO_STR. DATA: WA_E1EVMEEM_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_E1EVMEEM_STR-MODCNT sy-vline
WA_E1EVMEEM_STR-EVTCOD sy-vline
WA_E1EVMEEM_STR-EVTID sy-vline
WA_E1EVMEEM_STR-EVTACT sy-vline
WA_E1EVMEEM_STR-MODREF sy-vline
WA_E1EVMEEM_STR-ESTATT sy-vline
WA_E1EVMEEM_STR-LOCCOD sy-vline
WA_E1EVMEEM_STR-LOCID1 sy-vline
WA_E1EVMEEM_STR-LOCID2 sy-vline
WA_E1EVMEEM_STR-LOCNAM sy-vline
WA_E1EVMEEM_STR-LOCZON sy-vline
WA_E1EVMEEM_STR-PARCOD sy-vline
WA_E1EVMEEM_STR-PARID sy-vline
WA_E1EVMEEM_STR-PARNAM sy-vline
WA_E1EVMEEM_STR-LANGUAGE sy-vline
WA_E1EVMEEM_STR-CRCCOD sy-vline
WA_E1EVMEEM_STR-CRCID sy-vline
WA_E1EVMEEM_STR-CHRTX sy-vline
WA_E1EVMEEM_STR-ETADUR sy-vline
WA_E1EVMEEM_STR-ETXDAT sy-vline
WA_E1EVMEEM_STR-ETXTIM sy-vline
WA_E1EVMEEM_STR-ETXZON sy-vline
WA_E1EVMEEM_STR-ETEADT sy-vline
WA_E1EVMEEM_STR-ETEATI sy-vline
WA_E1EVMEEM_STR-ETLTDT sy-vline
WA_E1EVMEEM_STR-ETLTTI sy-vline
WA_E1EVMEEM_STR-MSGDUR sy-vline
WA_E1EVMEEM_STR-MSGDAT sy-vline
WA_E1EVMEEM_STR-MSGTIM sy-vline
WA_E1EVMEEM_STR-MSGZON sy-vline
WA_E1EVMEEM_STR-MSEADT sy-vline
WA_E1EVMEEM_STR-MSEATI sy-vline
WA_E1EVMEEM_STR-MSLTDT sy-vline
WA_E1EVMEEM_STR-MSLTTI sy-vline
WA_E1EVMEEM_STR-DATE1 sy-vline
WA_E1EVMEEM_STR-TIME1 sy-vline
WA_E1EVMEEM_STR-TZONE1 sy-vline
WA_E1EVMEEM_STR-DATE2 sy-vline
WA_E1EVMEEM_STR-TIME2 sy-vline
WA_E1EVMEEM_STR-TZONE2 sy-vline
WA_E1EVMEEM_STR-DATE3 sy-vline
WA_E1EVMEEM_STR-TIME3 sy-vline
WA_E1EVMEEM_STR-TZONE3 sy-vline
WA_E1EVMEEM_STR-DATE4 sy-vline
WA_E1EVMEEM_STR-TIME4 sy-vline
WA_E1EVMEEM_STR-TZONE4 sy-vline
WA_E1EVMEEM_STR-DATE5 sy-vline
WA_E1EVMEEM_STR-TIME5 sy-vline
WA_E1EVMEEM_STR-TZONE5 sy-vline
WA_E1EVMEEM_STR-DATACS sy-vline
WA_E1EVMEEM_STR-DATAID sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.