ABAP Select data from SAP table E1EDPR1 into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP E1EDPR1 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to E1EDPR1. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the E1EDPR1 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_E1EDPR1 TYPE STANDARD TABLE OF E1EDPR1,
      WA_E1EDPR1 TYPE E1EDPR1,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <E1EDPR1> TYPE E1EDPR1.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_E1EDPR1.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM E1EDPR1
  INTO TABLE IT_E1EDPR1.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM E1EDPR1
*  INTO TABLE @DATA(IT_E1EDPR12).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_E1EDPR1 INDEX 1 INTO DATA(WA_E1EDPR12).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_E1EDPR1 ASSIGNING <E1EDPR1>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<E1EDPR1>-RTY01 = 1.
<E1EDPR1>-RFN01 = 1.
<E1EDPR1>-RTY02 = 1.
<E1EDPR1>-RFN02 = 1.
<E1EDPR1>-RTY03 = 1.
ENDLOOP.

LOOP AT IT_E1EDPR1 INTO WA_E1EDPR1.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_E1EDPR1-RFN03, sy-vline,
WA_E1EDPR1-RTY04, sy-vline,
WA_E1EDPR1-RFN04, sy-vline,
WA_E1EDPR1-RTY05, sy-vline,
WA_E1EDPR1-RFN05, sy-vline,
WA_E1EDPR1-RTY06, sy-vline.
ENDLOOP. *Add any further fields from structure WA_E1EDPR1 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_E1EDPR1 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_E1EDPR1 INTO WA_E1EDPR1. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_E1EDPR1_STR,
RTY01 TYPE STRING,
RFN01 TYPE STRING,
RTY02 TYPE STRING,
RFN02 TYPE STRING,
RTY03 TYPE STRING,
RFN03 TYPE STRING,
RTY04 TYPE STRING,
RFN04 TYPE STRING,
RTY05 TYPE STRING,
RFN05 TYPE STRING,
RTY06 TYPE STRING,
RFN06 TYPE STRING,
RTY07 TYPE STRING,
RFN07 TYPE STRING,
RTY08 TYPE STRING,
RFN08 TYPE STRING,
RTY09 TYPE STRING,
RFN09 TYPE STRING,
RTY10 TYPE STRING,
RFN10 TYPE STRING,
RTY11 TYPE STRING,
RFN11 TYPE STRING,
RTY12 TYPE STRING,
RFN12 TYPE STRING,
RTY13 TYPE STRING,
RFN13 TYPE STRING,
RTY14 TYPE STRING,
RFN14 TYPE STRING,
RTY15 TYPE STRING,
RFN15 TYPE STRING,END OF T_EKKO_STR. DATA: WA_E1EDPR1_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_E1EDPR1_STR-RTY01 sy-vline
WA_E1EDPR1_STR-RFN01 sy-vline
WA_E1EDPR1_STR-RTY02 sy-vline
WA_E1EDPR1_STR-RFN02 sy-vline
WA_E1EDPR1_STR-RTY03 sy-vline
WA_E1EDPR1_STR-RFN03 sy-vline
WA_E1EDPR1_STR-RTY04 sy-vline
WA_E1EDPR1_STR-RFN04 sy-vline
WA_E1EDPR1_STR-RTY05 sy-vline
WA_E1EDPR1_STR-RFN05 sy-vline
WA_E1EDPR1_STR-RTY06 sy-vline
WA_E1EDPR1_STR-RFN06 sy-vline
WA_E1EDPR1_STR-RTY07 sy-vline
WA_E1EDPR1_STR-RFN07 sy-vline
WA_E1EDPR1_STR-RTY08 sy-vline
WA_E1EDPR1_STR-RFN08 sy-vline
WA_E1EDPR1_STR-RTY09 sy-vline
WA_E1EDPR1_STR-RFN09 sy-vline
WA_E1EDPR1_STR-RTY10 sy-vline
WA_E1EDPR1_STR-RFN10 sy-vline
WA_E1EDPR1_STR-RTY11 sy-vline
WA_E1EDPR1_STR-RFN11 sy-vline
WA_E1EDPR1_STR-RTY12 sy-vline
WA_E1EDPR1_STR-RFN12 sy-vline
WA_E1EDPR1_STR-RTY13 sy-vline
WA_E1EDPR1_STR-RFN13 sy-vline
WA_E1EDPR1_STR-RTY14 sy-vline
WA_E1EDPR1_STR-RFN14 sy-vline
WA_E1EDPR1_STR-RTY15 sy-vline
WA_E1EDPR1_STR-RFN15 sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.