ABAP Select data from SAP table E1EDPD1 into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP E1EDPD1 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to E1EDPD1. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the E1EDPD1 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_E1EDPD1 TYPE STANDARD TABLE OF E1EDPD1,
      WA_E1EDPD1 TYPE E1EDPD1,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <E1EDPD1> TYPE E1EDPD1.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_E1EDPD1.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM E1EDPD1
  INTO TABLE IT_E1EDPD1.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM E1EDPD1
*  INTO TABLE @DATA(IT_E1EDPD12).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_E1EDPD1 INDEX 1 INTO DATA(WA_E1EDPD12).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_E1EDPD1 ASSIGNING <E1EDPD1>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<E1EDPD1>-KNTTP = 1.
<E1EDPD1>-BEDNR = 1.
<E1EDPD1>-PRSDR = 1.
<E1EDPD1>-UNTTO = 1.
<E1EDPD1>-UEBTO = 1.
ENDLOOP.

LOOP AT IT_E1EDPD1 INTO WA_E1EDPD1.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_E1EDPD1-UEBTK, sy-vline,
WA_E1EDPD1-INSMK, sy-vline,
WA_E1EDPD1-SPINF, sy-vline,
WA_E1EDPD1-MAHN1, sy-vline,
WA_E1EDPD1-MAHN2, sy-vline,
WA_E1EDPD1-MAHN3, sy-vline.
ENDLOOP. *Add any further fields from structure WA_E1EDPD1 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_E1EDPD1 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_E1EDPD1 INTO WA_E1EDPD1. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_E1EDPD1_STR,
KNTTP TYPE STRING,
BEDNR TYPE STRING,
PRSDR TYPE STRING,
UNTTO TYPE STRING,
UEBTO TYPE STRING,
UEBTK TYPE STRING,
INSMK TYPE STRING,
SPINF TYPE STRING,
MAHN1 TYPE STRING,
MAHN2 TYPE STRING,
MAHN3 TYPE STRING,
BSTAE TYPE STRING,
LABNR TYPE STRING,
KZABS TYPE STRING,
SCHPR TYPE STRING,
MWSKZ TYPE STRING,
WEBRE TYPE STRING,
WERKS TYPE STRING,
LGORT TYPE STRING,
ABMNG TYPE STRING,
MSGFN TYPE STRING,
ELIKZ TYPE STRING,
MHDRZ TYPE STRING,
RETPO TYPE STRING,
IPRKZ TYPE STRING,END OF T_EKKO_STR. DATA: WA_E1EDPD1_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_E1EDPD1_STR-KNTTP sy-vline
WA_E1EDPD1_STR-BEDNR sy-vline
WA_E1EDPD1_STR-PRSDR sy-vline
WA_E1EDPD1_STR-UNTTO sy-vline
WA_E1EDPD1_STR-UEBTO sy-vline
WA_E1EDPD1_STR-UEBTK sy-vline
WA_E1EDPD1_STR-INSMK sy-vline
WA_E1EDPD1_STR-SPINF sy-vline
WA_E1EDPD1_STR-MAHN1 sy-vline
WA_E1EDPD1_STR-MAHN2 sy-vline
WA_E1EDPD1_STR-MAHN3 sy-vline
WA_E1EDPD1_STR-BSTAE sy-vline
WA_E1EDPD1_STR-LABNR sy-vline
WA_E1EDPD1_STR-KZABS sy-vline
WA_E1EDPD1_STR-SCHPR sy-vline
WA_E1EDPD1_STR-MWSKZ sy-vline
WA_E1EDPD1_STR-WEBRE sy-vline
WA_E1EDPD1_STR-WERKS sy-vline
WA_E1EDPD1_STR-LGORT sy-vline
WA_E1EDPD1_STR-ABMNG sy-vline
WA_E1EDPD1_STR-MSGFN sy-vline
WA_E1EDPD1_STR-ELIKZ sy-vline
WA_E1EDPD1_STR-MHDRZ sy-vline
WA_E1EDPD1_STR-RETPO sy-vline
WA_E1EDPD1_STR-IPRKZ sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.