ABAP Select data from SAP table E1EDP09 into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP E1EDP09 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to E1EDP09. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the E1EDP09 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_E1EDP09 TYPE STANDARD TABLE OF E1EDP09,
      WA_E1EDP09 TYPE E1EDP09,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <E1EDP09> TYPE E1EDP09.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_E1EDP09.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM E1EDP09
  INTO TABLE IT_E1EDP09.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM E1EDP09
*  INTO TABLE @DATA(IT_E1EDP092).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_E1EDP09 INDEX 1 INTO DATA(WA_E1EDP092).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_E1EDP09 ASSIGNING <E1EDP09>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<E1EDP09>-HLNUM = 1.
<E1EDP09>-PARENT = 1.
<E1EDP09>-VBELN = 1.
<E1EDP09>-POSNR = 1.
<E1EDP09>-ABRVW = 1.
ENDLOOP.

LOOP AT IT_E1EDP09 INTO WA_E1EDP09.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_E1EDP09-MATNR, sy-vline,
WA_E1EDP09-WERKS, sy-vline,
WA_E1EDP09-LGORT, sy-vline,
WA_E1EDP09-CHARG, sy-vline,
WA_E1EDP09-KDMAT, sy-vline,
WA_E1EDP09-LFIMG, sy-vline.
ENDLOOP. *Add any further fields from structure WA_E1EDP09 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_E1EDP09 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_E1EDP09 INTO WA_E1EDP09. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_E1EDP09_STR,
HLNUM TYPE STRING,
PARENT TYPE STRING,
VBELN TYPE STRING,
POSNR TYPE STRING,
ABRVW TYPE STRING,
MATNR TYPE STRING,
WERKS TYPE STRING,
LGORT TYPE STRING,
CHARG TYPE STRING,
KDMAT TYPE STRING,
LFIMG TYPE STRING,
VRKME TYPE STRING,
BTGEW TYPE STRING,
NTGEW TYPE STRING,
GEWEI TYPE STRING,
VOLUM TYPE STRING,
VOLEH TYPE STRING,
ARKTX TYPE STRING,
EANNR TYPE STRING,
STAWN TYPE STRING,
EXART TYPE STRING,
EXART_BEZ TYPE STRING,
HERKL TYPE STRING,
HERKR TYPE STRING,
GRWRT TYPE STRING,
UEPOS TYPE STRING,
TXTZ1 TYPE STRING,
TXTZ2 TYPE STRING,
ZOLLG TYPE STRING,
MWSAT TYPE STRING,
BERLI TYPE STRING,
TSTKY TYPE STRING,
DOKPF TYPE STRING,
DESRE TYPE STRING,
ECHNO TYPE STRING,
ECHDT TYPE STRING,
VBRST TYPE STRING,
ZEIKD TYPE STRING,
TARIF TYPE STRING,
AMERK TYPE STRING,
AMERT TYPE STRING,
IMPLN TYPE STRING,
EXPLN TYPE STRING,
CHBEZ TYPE STRING,
KLAS1 TYPE STRING,
IMOCE TYPE STRING,
IMCNR TYPE STRING,
UNNUM TYPE STRING,
AESKD TYPE STRING,
PREFE TYPE STRING,
LABNK TYPE STRING,
ABRDT TYPE STRING,END OF T_EKKO_STR. DATA: WA_E1EDP09_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_E1EDP09_STR-HLNUM sy-vline
WA_E1EDP09_STR-PARENT sy-vline
WA_E1EDP09_STR-VBELN sy-vline
WA_E1EDP09_STR-POSNR sy-vline
WA_E1EDP09_STR-ABRVW sy-vline
WA_E1EDP09_STR-MATNR sy-vline
WA_E1EDP09_STR-WERKS sy-vline
WA_E1EDP09_STR-LGORT sy-vline
WA_E1EDP09_STR-CHARG sy-vline
WA_E1EDP09_STR-KDMAT sy-vline
WA_E1EDP09_STR-LFIMG sy-vline
WA_E1EDP09_STR-VRKME sy-vline
WA_E1EDP09_STR-BTGEW sy-vline
WA_E1EDP09_STR-NTGEW sy-vline
WA_E1EDP09_STR-GEWEI sy-vline
WA_E1EDP09_STR-VOLUM sy-vline
WA_E1EDP09_STR-VOLEH sy-vline
WA_E1EDP09_STR-ARKTX sy-vline
WA_E1EDP09_STR-EANNR sy-vline
WA_E1EDP09_STR-STAWN sy-vline
WA_E1EDP09_STR-EXART sy-vline
WA_E1EDP09_STR-EXART_BEZ sy-vline
WA_E1EDP09_STR-HERKL sy-vline
WA_E1EDP09_STR-HERKR sy-vline
WA_E1EDP09_STR-GRWRT sy-vline
WA_E1EDP09_STR-UEPOS sy-vline
WA_E1EDP09_STR-TXTZ1 sy-vline
WA_E1EDP09_STR-TXTZ2 sy-vline
WA_E1EDP09_STR-ZOLLG sy-vline
WA_E1EDP09_STR-MWSAT sy-vline
WA_E1EDP09_STR-BERLI sy-vline
WA_E1EDP09_STR-TSTKY sy-vline
WA_E1EDP09_STR-DOKPF sy-vline
WA_E1EDP09_STR-DESRE sy-vline
WA_E1EDP09_STR-ECHNO sy-vline
WA_E1EDP09_STR-ECHDT sy-vline
WA_E1EDP09_STR-VBRST sy-vline
WA_E1EDP09_STR-ZEIKD sy-vline
WA_E1EDP09_STR-TARIF sy-vline
WA_E1EDP09_STR-AMERK sy-vline
WA_E1EDP09_STR-AMERT sy-vline
WA_E1EDP09_STR-IMPLN sy-vline
WA_E1EDP09_STR-EXPLN sy-vline
WA_E1EDP09_STR-CHBEZ sy-vline
WA_E1EDP09_STR-KLAS1 sy-vline
WA_E1EDP09_STR-IMOCE sy-vline
WA_E1EDP09_STR-IMCNR sy-vline
WA_E1EDP09_STR-UNNUM sy-vline
WA_E1EDP09_STR-AESKD sy-vline
WA_E1EDP09_STR-PREFE sy-vline
WA_E1EDP09_STR-LABNK sy-vline
WA_E1EDP09_STR-ABRDT sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.