ABAP Select data from SAP table E1EDL26 into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP E1EDL26 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to E1EDL26. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the E1EDL26 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_E1EDL26 TYPE STANDARD TABLE OF E1EDL26,
      WA_E1EDL26 TYPE E1EDL26,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <E1EDL26> TYPE E1EDL26.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_E1EDL26.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM E1EDL26
  INTO TABLE IT_E1EDL26.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM E1EDL26
*  INTO TABLE @DATA(IT_E1EDL262).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_E1EDL26 INDEX 1 INTO DATA(WA_E1EDL262).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_E1EDL26 ASSIGNING <E1EDL26>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<E1EDL26>-PSTYV = 1.
<E1EDL26>-MATKL = 1.
<E1EDL26>-PRODH = 1.
<E1EDL26>-UMVKZ = 1.
<E1EDL26>-UMVKN = 1.
ENDLOOP.

LOOP AT IT_E1EDL26 INTO WA_E1EDL26.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_E1EDL26-KZTLF, sy-vline,
WA_E1EDL26-UEBTK, sy-vline,
WA_E1EDL26-UEBTO, sy-vline,
WA_E1EDL26-UNTTO, sy-vline,
WA_E1EDL26-CHSPL, sy-vline,
WA_E1EDL26-XCHBW, sy-vline.
ENDLOOP. *Add any further fields from structure WA_E1EDL26 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_E1EDL26 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_E1EDL26 INTO WA_E1EDL26. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_E1EDL26_STR,
PSTYV TYPE STRING,
MATKL TYPE STRING,
PRODH TYPE STRING,
UMVKZ TYPE STRING,
UMVKN TYPE STRING,
KZTLF TYPE STRING,
UEBTK TYPE STRING,
UEBTO TYPE STRING,
UNTTO TYPE STRING,
CHSPL TYPE STRING,
XCHBW TYPE STRING,
POSAR TYPE STRING,
SOBKZ TYPE STRING,
PCKPF TYPE STRING,
MAGRV TYPE STRING,
SHKZG TYPE STRING,
KOQUI TYPE STRING,
AKTNR TYPE STRING,
KZUMW TYPE STRING,
KVGR1 TYPE STRING,
KVGR2 TYPE STRING,
KVGR3 TYPE STRING,
KVGR4 TYPE STRING,
KVGR5 TYPE STRING,
MVGR1 TYPE STRING,
MVGR2 TYPE STRING,
MVGR3 TYPE STRING,
MVGR4 TYPE STRING,
MVGR5 TYPE STRING,
LIFEXPOS2 TYPE STRING,
CQU_SA TYPE STRING,
CQU_SA_UNIT TYPE STRING,
CQU_ITQS TYPE STRING,
CQU_ITQS_UNIT TYPE STRING,
VBUMG_BME TYPE STRING,
SGT_RCAT TYPE STRING,
SGT_SCAT TYPE STRING,
MATNR_LONG TYPE STRING,
MATWA_LONG TYPE STRING,
REQ_SEG_LONG TYPE STRING,
STK_SEG_LONG TYPE STRING,END OF T_EKKO_STR. DATA: WA_E1EDL26_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_E1EDL26_STR-PSTYV sy-vline
WA_E1EDL26_STR-MATKL sy-vline
WA_E1EDL26_STR-PRODH sy-vline
WA_E1EDL26_STR-UMVKZ sy-vline
WA_E1EDL26_STR-UMVKN sy-vline
WA_E1EDL26_STR-KZTLF sy-vline
WA_E1EDL26_STR-UEBTK sy-vline
WA_E1EDL26_STR-UEBTO sy-vline
WA_E1EDL26_STR-UNTTO sy-vline
WA_E1EDL26_STR-CHSPL sy-vline
WA_E1EDL26_STR-XCHBW sy-vline
WA_E1EDL26_STR-POSAR sy-vline
WA_E1EDL26_STR-SOBKZ sy-vline
WA_E1EDL26_STR-PCKPF sy-vline
WA_E1EDL26_STR-MAGRV sy-vline
WA_E1EDL26_STR-SHKZG sy-vline
WA_E1EDL26_STR-KOQUI sy-vline
WA_E1EDL26_STR-AKTNR sy-vline
WA_E1EDL26_STR-KZUMW sy-vline
WA_E1EDL26_STR-KVGR1 sy-vline
WA_E1EDL26_STR-KVGR2 sy-vline
WA_E1EDL26_STR-KVGR3 sy-vline
WA_E1EDL26_STR-KVGR4 sy-vline
WA_E1EDL26_STR-KVGR5 sy-vline
WA_E1EDL26_STR-MVGR1 sy-vline
WA_E1EDL26_STR-MVGR2 sy-vline
WA_E1EDL26_STR-MVGR3 sy-vline
WA_E1EDL26_STR-MVGR4 sy-vline
WA_E1EDL26_STR-MVGR5 sy-vline
WA_E1EDL26_STR-LIFEXPOS2 sy-vline
WA_E1EDL26_STR-CQU_SA sy-vline
WA_E1EDL26_STR-CQU_SA_UNIT sy-vline
WA_E1EDL26_STR-CQU_ITQS sy-vline
WA_E1EDL26_STR-CQU_ITQS_UNIT sy-vline
WA_E1EDL26_STR-VBUMG_BME sy-vline
WA_E1EDL26_STR-SGT_RCAT sy-vline
WA_E1EDL26_STR-SGT_SCAT sy-vline
WA_E1EDL26_STR-MATNR_LONG sy-vline
WA_E1EDL26_STR-MATWA_LONG sy-vline
WA_E1EDL26_STR-REQ_SEG_LONG sy-vline
WA_E1EDL26_STR-STK_SEG_LONG sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.