ABAP Select data from SAP table E1EDD19 into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP E1EDD19 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to E1EDD19. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the E1EDD19 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_E1EDD19 TYPE STANDARD TABLE OF E1EDD19,
      WA_E1EDD19 TYPE E1EDD19,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <E1EDD19> TYPE E1EDD19.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_E1EDD19.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM E1EDD19
  INTO TABLE IT_E1EDD19.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM E1EDD19
*  INTO TABLE @DATA(IT_E1EDD192).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_E1EDD19 INDEX 1 INTO DATA(WA_E1EDD192).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_E1EDD19 ASSIGNING <E1EDD19>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<E1EDD19>-ABS_ACT = 1.
<E1EDD19>-ABS_ACT_U = 1.
<E1EDD19>-REL_SPEC_ACT = 1.
<E1EDD19>-REL_SPEC_ACT_U = 1.
<E1EDD19>-CONTAMINATION = 1.
ENDLOOP.

LOOP AT IT_E1EDD19 INTO WA_E1EDD19.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_E1EDD19-CONTAMINATION_U, sy-vline,
WA_E1EDD19-DOSE_RATE, sy-vline,
WA_E1EDD19-DOSE_RATE_U, sy-vline,
WA_E1EDD19-MAX_ACT1, sy-vline,
WA_E1EDD19-MAX_ACT1_U, sy-vline,
WA_E1EDD19-ACT1_UNLIMIT, sy-vline.
ENDLOOP. *Add any further fields from structure WA_E1EDD19 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_E1EDD19 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_E1EDD19 INTO WA_E1EDD19. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_E1EDD19_STR,
ABS_ACT TYPE STRING,
ABS_ACT_U TYPE STRING,
REL_SPEC_ACT TYPE STRING,
REL_SPEC_ACT_U TYPE STRING,
CONTAMINATION TYPE STRING,
CONTAMINATION_U TYPE STRING,
DOSE_RATE TYPE STRING,
DOSE_RATE_U TYPE STRING,
MAX_ACT1 TYPE STRING,
MAX_ACT1_U TYPE STRING,
ACT1_UNLIMIT TYPE STRING,
MAX_ACT2 TYPE STRING,
MAX_ACT2_U TYPE STRING,
ACT2_UNLIMIT TYPE STRING,
ACT_SUB_PACK TYPE STRING,
ACT_SUB_PACK_U TYPE STRING,
MAX_ACT_CONSG TYPE STRING,
MAX_ACT_CONSG_U TYPE STRING,
MULT_ACT_SGL TYPE STRING,
REF_ACT_SGL TYPE STRING,
MULT_ACT_PACK TYPE STRING,
REF_ACT_PACK TYPE STRING,
MAX_CONT_A TYPE STRING,
MAX_CONT_A_U TYPE STRING,
MAX_CONT_B_G TYPE STRING,
MAX_CONT_B_G_U TYPE STRING,
MAX_DOSE_UNP TYPE STRING,
MAX_DOSE_UNP_U TYPE STRING,
DIST_DOSE_UNP TYPE STRING,
DIST_DOSE_UNP_U TYPE STRING,
NO_DIST_UNP TYPE STRING,
MAX_DOSE_PACK TYPE STRING,
MAX_DOSE_PACK_U TYPE STRING,
DIST_DOSE_PACK TYPE STRING,
DIST_DOSE_PACK_U TYPE STRING,
NO_DIST_PACK TYPE STRING,
MAX_ACT_SGL_DC TYPE STRING,
MAX_ACT_SGL_U_DC TYPE STRING,
ACT_SGL_UNLIM_DC TYPE STRING,
MAX_ACT_PAC_DC TYPE STRING,
MAX_ACT_PAC_U_DC TYPE STRING,
ACT_PAC_UNLIM_DC TYPE STRING,
EXCPT_PAC_OPT_DC TYPE STRING,
MAX_GRS_WGHT_DC TYPE STRING,
U_MAX_GRS_WGT_DC TYPE STRING,
ACT_EMIS_TYPE TYPE STRING,
MAX_NEM_DC TYPE STRING,
MAX_NEM_U_DC TYPE STRING,END OF T_EKKO_STR. DATA: WA_E1EDD19_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_E1EDD19_STR-ABS_ACT sy-vline
WA_E1EDD19_STR-ABS_ACT_U sy-vline
WA_E1EDD19_STR-REL_SPEC_ACT sy-vline
WA_E1EDD19_STR-REL_SPEC_ACT_U sy-vline
WA_E1EDD19_STR-CONTAMINATION sy-vline
WA_E1EDD19_STR-CONTAMINATION_U sy-vline
WA_E1EDD19_STR-DOSE_RATE sy-vline
WA_E1EDD19_STR-DOSE_RATE_U sy-vline
WA_E1EDD19_STR-MAX_ACT1 sy-vline
WA_E1EDD19_STR-MAX_ACT1_U sy-vline
WA_E1EDD19_STR-ACT1_UNLIMIT sy-vline
WA_E1EDD19_STR-MAX_ACT2 sy-vline
WA_E1EDD19_STR-MAX_ACT2_U sy-vline
WA_E1EDD19_STR-ACT2_UNLIMIT sy-vline
WA_E1EDD19_STR-ACT_SUB_PACK sy-vline
WA_E1EDD19_STR-ACT_SUB_PACK_U sy-vline
WA_E1EDD19_STR-MAX_ACT_CONSG sy-vline
WA_E1EDD19_STR-MAX_ACT_CONSG_U sy-vline
WA_E1EDD19_STR-MULT_ACT_SGL sy-vline
WA_E1EDD19_STR-REF_ACT_SGL sy-vline
WA_E1EDD19_STR-MULT_ACT_PACK sy-vline
WA_E1EDD19_STR-REF_ACT_PACK sy-vline
WA_E1EDD19_STR-MAX_CONT_A sy-vline
WA_E1EDD19_STR-MAX_CONT_A_U sy-vline
WA_E1EDD19_STR-MAX_CONT_B_G sy-vline
WA_E1EDD19_STR-MAX_CONT_B_G_U sy-vline
WA_E1EDD19_STR-MAX_DOSE_UNP sy-vline
WA_E1EDD19_STR-MAX_DOSE_UNP_U sy-vline
WA_E1EDD19_STR-DIST_DOSE_UNP sy-vline
WA_E1EDD19_STR-DIST_DOSE_UNP_U sy-vline
WA_E1EDD19_STR-NO_DIST_UNP sy-vline
WA_E1EDD19_STR-MAX_DOSE_PACK sy-vline
WA_E1EDD19_STR-MAX_DOSE_PACK_U sy-vline
WA_E1EDD19_STR-DIST_DOSE_PACK sy-vline
WA_E1EDD19_STR-DIST_DOSE_PACK_U sy-vline
WA_E1EDD19_STR-NO_DIST_PACK sy-vline
WA_E1EDD19_STR-MAX_ACT_SGL_DC sy-vline
WA_E1EDD19_STR-MAX_ACT_SGL_U_DC sy-vline
WA_E1EDD19_STR-ACT_SGL_UNLIM_DC sy-vline
WA_E1EDD19_STR-MAX_ACT_PAC_DC sy-vline
WA_E1EDD19_STR-MAX_ACT_PAC_U_DC sy-vline
WA_E1EDD19_STR-ACT_PAC_UNLIM_DC sy-vline
WA_E1EDD19_STR-EXCPT_PAC_OPT_DC sy-vline
WA_E1EDD19_STR-MAX_GRS_WGHT_DC sy-vline
WA_E1EDD19_STR-U_MAX_GRS_WGT_DC sy-vline
WA_E1EDD19_STR-ACT_EMIS_TYPE sy-vline
WA_E1EDD19_STR-MAX_NEM_DC sy-vline
WA_E1EDD19_STR-MAX_NEM_U_DC sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.