ABAP Select data from SAP table E1EDD17 into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP E1EDD17 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to E1EDD17. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the E1EDD17 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_E1EDD17 TYPE STANDARD TABLE OF E1EDD17,
      WA_E1EDD17 TYPE E1EDD17,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <E1EDD17> TYPE E1EDD17.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_E1EDD17.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM E1EDD17
  INTO TABLE IT_E1EDD17.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM E1EDD17
*  INTO TABLE @DATA(IT_E1EDD172).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_E1EDD17 INDEX 1 INTO DATA(WA_E1EDD172).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_E1EDD17 ASSIGNING <E1EDD17>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<E1EDD17>-PACKAGE_MATNR = 1.
<E1EDD17>-PRIO_ALTERN = 1.
<E1EDD17>-FLG_RELEASED = 1.
<E1EDD17>-FLG_TRANS_PERM = 1.
<E1EDD17>-FLG_NO_DG = 1.
ENDLOOP.

LOOP AT IT_E1EDD17 INTO WA_E1EDD17.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_E1EDD17-FLG_LQ, sy-vline,
WA_E1EDD17-FLG_RQ, sy-vline,
WA_E1EDD17-INSTR_ENCL, sy-vline,
WA_E1EDD17-FLG_SINGLE_PACK, sy-vline,
WA_E1EDD17-PACOD, sy-vline,
WA_E1EDD17-QUANT_OUT_PACK, sy-vline.
ENDLOOP. *Add any further fields from structure WA_E1EDD17 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_E1EDD17 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_E1EDD17 INTO WA_E1EDD17. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_E1EDD17_STR,
PACKAGE_MATNR TYPE STRING,
PRIO_ALTERN TYPE STRING,
FLG_RELEASED TYPE STRING,
FLG_TRANS_PERM TYPE STRING,
FLG_NO_DG TYPE STRING,
FLG_LQ TYPE STRING,
FLG_RQ TYPE STRING,
INSTR_ENCL TYPE STRING,
FLG_SINGLE_PACK TYPE STRING,
PACOD TYPE STRING,
QUANT_OUT_PACK TYPE STRING,
U_QUANT_OUT_PACK TYPE STRING,
RECN_SUB TYPE STRING,
RECN_CLASS TYPE STRING,
FLG_CC TYPE STRING,
FLG_PACKED TYPE STRING,
TRANSPORT_TYPE TYPE STRING,
APPROVAL_CODE TYPE STRING,
FLG_EQ TYPE STRING,
DGREL_TRANSIND01 TYPE STRING,
DGREL_TRANSIND02 TYPE STRING,
DGREL_TRANSIND03 TYPE STRING,
DGREL_TRANSIND04 TYPE STRING,
DGREL_TRANSIND05 TYPE STRING,
DGREL_TRANSIND06 TYPE STRING,
DGREL_TRANSIND07 TYPE STRING,
DGREL_TRANSIND08 TYPE STRING,
PACKAGE_MATNR_EXTERNAL TYPE STRING,
PACKAGE_MATNR_VERSION TYPE STRING,
PACKAGE_MATNR_GUID TYPE STRING,
PACKAGE_MATNR_LONG TYPE STRING,END OF T_EKKO_STR. DATA: WA_E1EDD17_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_E1EDD17_STR-PACKAGE_MATNR sy-vline
WA_E1EDD17_STR-PRIO_ALTERN sy-vline
WA_E1EDD17_STR-FLG_RELEASED sy-vline
WA_E1EDD17_STR-FLG_TRANS_PERM sy-vline
WA_E1EDD17_STR-FLG_NO_DG sy-vline
WA_E1EDD17_STR-FLG_LQ sy-vline
WA_E1EDD17_STR-FLG_RQ sy-vline
WA_E1EDD17_STR-INSTR_ENCL sy-vline
WA_E1EDD17_STR-FLG_SINGLE_PACK sy-vline
WA_E1EDD17_STR-PACOD sy-vline
WA_E1EDD17_STR-QUANT_OUT_PACK sy-vline
WA_E1EDD17_STR-U_QUANT_OUT_PACK sy-vline
WA_E1EDD17_STR-RECN_SUB sy-vline
WA_E1EDD17_STR-RECN_CLASS sy-vline
WA_E1EDD17_STR-FLG_CC sy-vline
WA_E1EDD17_STR-FLG_PACKED sy-vline
WA_E1EDD17_STR-TRANSPORT_TYPE sy-vline
WA_E1EDD17_STR-APPROVAL_CODE sy-vline
WA_E1EDD17_STR-FLG_EQ sy-vline
WA_E1EDD17_STR-DGREL_TRANSIND01 sy-vline
WA_E1EDD17_STR-DGREL_TRANSIND02 sy-vline
WA_E1EDD17_STR-DGREL_TRANSIND03 sy-vline
WA_E1EDD17_STR-DGREL_TRANSIND04 sy-vline
WA_E1EDD17_STR-DGREL_TRANSIND05 sy-vline
WA_E1EDD17_STR-DGREL_TRANSIND06 sy-vline
WA_E1EDD17_STR-DGREL_TRANSIND07 sy-vline
WA_E1EDD17_STR-DGREL_TRANSIND08 sy-vline
WA_E1EDD17_STR-PACKAGE_MATNR_EXTERNAL sy-vline
WA_E1EDD17_STR-PACKAGE_MATNR_VERSION sy-vline
WA_E1EDD17_STR-PACKAGE_MATNR_GUID sy-vline
WA_E1EDD17_STR-PACKAGE_MATNR_LONG sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.