ABAP Select data from SAP table E1BPPCMAS into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP E1BPPCMAS table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to E1BPPCMAS. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the E1BPPCMAS table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_E1BPPCMAS TYPE STANDARD TABLE OF E1BPPCMAS,
WA_E1BPPCMAS TYPE E1BPPCMAS,
GD_STR TYPE STRING.
DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.
FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <E1BPPCMAS> TYPE E1BPPCMAS.
*Process all fields in table header/work area as string values
PERFORM process_as_string_field_values CHANGING wa_E1BPPCMAS.
SELECT *
*restrict ABAP select to first 10 rows
UP TO 10 ROWS
FROM E1BPPCMAS
INTO TABLE IT_E1BPPCMAS.
*Select data and declare internal table using in-line method @DATA
*SELECT *
* FROM E1BPPCMAS
* INTO TABLE @DATA(IT_E1BPPCMAS2).
*--Further methods of using ABAP code to select data from SAP database tables
*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_E1BPPCMAS INDEX 1 INTO DATA(WA_E1BPPCMAS2).
*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_E1BPPCMAS ASSIGNING <E1BPPCMAS>.
*To update a field value using a field symbol simply change the value via the field symbol pointer<E1BPPCMAS>-BBPPCINS = 1.
<E1BPPCMAS>-PCNUM = 1.
<E1BPPCMAS>-PCTYP = 1.
<E1BPPCMAS>-PCBEGRU = 1.
<E1BPPCMAS>-HOLDER_TYPE = 1.
ENDLOOP. LOOP AT IT_E1BPPCMAS INTO WA_E1BPPCMAS. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_E1BPPCMAS-HOLDER_ID, sy-vline,
WA_E1BPPCMAS-HOLDER_NAME, sy-vline,
WA_E1BPPCMAS-AGENT1_TYPE, sy-vline,
WA_E1BPPCMAS-WFAGENT1, sy-vline,
WA_E1BPPCMAS-AGENT2_TYPE, sy-vline,
WA_E1BPPCMAS-WFAGENT2, sy-vline.
ENDLOOP. *Add any further fields from structure WA_E1BPPCMAS you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_E1BPPCMAS TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_E1BPPCMAS INTO WA_E1BPPCMAS. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_E1BPPCMAS_STR,
BBPPCINS TYPE STRING,
PCNUM TYPE STRING,
PCTYP TYPE STRING,
PCBEGRU TYPE STRING,
HOLDER_TYPE TYPE STRING,
HOLDER_ID TYPE STRING,
HOLDER_NAME TYPE STRING,
AGENT1_TYPE TYPE STRING,
WFAGENT1 TYPE STRING,
AGENT2_TYPE TYPE STRING,
WFAGENT2 TYPE STRING,
PCDAT_FROM TYPE STRING,
PCDAT_TO TYPE STRING,
APPROVAL1 TYPE STRING,
APPROVAL2 TYPE STRING,
TALIMIT TYPE STRING,
TOLIMIT TYPE STRING,
VALID_FROM TYPE STRING,
COMP_CODE TYPE STRING,
LOC_CURRCY TYPE STRING,
CURREN_ISO TYPE STRING,
GL_ACCOUNT TYPE STRING,
COSTCENTER TYPE STRING,
ORDERID TYPE STRING,
WBS_ELEMENT TYPE STRING,
FUNDS_CTR TYPE STRING,
FUND TYPE STRING,
FUNDS_RES TYPE STRING,
RES_ITEM TYPE STRING,END OF T_EKKO_STR. DATA: WA_E1BPPCMAS_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_E1BPPCMAS_STR-BBPPCINS sy-vline
WA_E1BPPCMAS_STR-PCNUM sy-vline
WA_E1BPPCMAS_STR-PCTYP sy-vline
WA_E1BPPCMAS_STR-PCBEGRU sy-vline
WA_E1BPPCMAS_STR-HOLDER_TYPE sy-vline
WA_E1BPPCMAS_STR-HOLDER_ID sy-vline
WA_E1BPPCMAS_STR-HOLDER_NAME sy-vline
WA_E1BPPCMAS_STR-AGENT1_TYPE sy-vline
WA_E1BPPCMAS_STR-WFAGENT1 sy-vline
WA_E1BPPCMAS_STR-AGENT2_TYPE sy-vline
WA_E1BPPCMAS_STR-WFAGENT2 sy-vline
WA_E1BPPCMAS_STR-PCDAT_FROM sy-vline
WA_E1BPPCMAS_STR-PCDAT_TO sy-vline
WA_E1BPPCMAS_STR-APPROVAL1 sy-vline
WA_E1BPPCMAS_STR-APPROVAL2 sy-vline
WA_E1BPPCMAS_STR-TALIMIT sy-vline
WA_E1BPPCMAS_STR-TOLIMIT sy-vline
WA_E1BPPCMAS_STR-VALID_FROM sy-vline
WA_E1BPPCMAS_STR-COMP_CODE sy-vline
WA_E1BPPCMAS_STR-LOC_CURRCY sy-vline
WA_E1BPPCMAS_STR-CURREN_ISO sy-vline
WA_E1BPPCMAS_STR-GL_ACCOUNT sy-vline
WA_E1BPPCMAS_STR-COSTCENTER sy-vline
WA_E1BPPCMAS_STR-ORDERID sy-vline
WA_E1BPPCMAS_STR-WBS_ELEMENT sy-vline
WA_E1BPPCMAS_STR-FUNDS_CTR sy-vline
WA_E1BPPCMAS_STR-FUND sy-vline
WA_E1BPPCMAS_STR-FUNDS_RES sy-vline
WA_E1BPPCMAS_STR-RES_ITEM sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.
