ABAP Select data from SAP table E1BPPCLOG into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP E1BPPCLOG table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to E1BPPCLOG. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the E1BPPCLOG table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_E1BPPCLOG TYPE STANDARD TABLE OF E1BPPCLOG,
      WA_E1BPPCLOG TYPE E1BPPCLOG,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <E1BPPCLOG> TYPE E1BPPCLOG.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_E1BPPCLOG.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM E1BPPCLOG
  INTO TABLE IT_E1BPPCLOG.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM E1BPPCLOG
*  INTO TABLE @DATA(IT_E1BPPCLOG2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_E1BPPCLOG INDEX 1 INTO DATA(WA_E1BPPCLOG2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_E1BPPCLOG ASSIGNING <E1BPPCLOG>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<E1BPPCLOG>-PC_LINE = 1.
<E1BPPCLOG>-PO_NUMBER = 1.
<E1BPPCLOG>-PO_ITEM = 1.
<E1BPPCLOG>-SD_DOC = 1.
<E1BPPCLOG>-ITM_NUMBER = 1.
ENDLOOP.

LOOP AT IT_E1BPPCLOG INTO WA_E1BPPCLOG.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_E1BPPCLOG-SHORT_TEXT, sy-vline,
WA_E1BPPCLOG-COM_CODE, sy-vline,
WA_E1BPPCLOG-EAN_UPC, sy-vline,
WA_E1BPPCLOG-QUANTITY, sy-vline,
WA_E1BPPCLOG-PO_UNIT, sy-vline,
WA_E1BPPCLOG-POUNIT_ISO, sy-vline.
ENDLOOP. *Add any further fields from structure WA_E1BPPCLOG you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_E1BPPCLOG TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_E1BPPCLOG INTO WA_E1BPPCLOG. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_E1BPPCLOG_STR,
PC_LINE TYPE STRING,
PO_NUMBER TYPE STRING,
PO_ITEM TYPE STRING,
SD_DOC TYPE STRING,
ITM_NUMBER TYPE STRING,
SHORT_TEXT TYPE STRING,
COM_CODE TYPE STRING,
EAN_UPC TYPE STRING,
QUANTITY TYPE STRING,
PO_UNIT TYPE STRING,
POUNIT_ISO TYPE STRING,
INV_QTY TYPE STRING,
SALES_UNIT TYPE STRING,
S_UNIT_ISO TYPE STRING,
TAX_CODE TYPE STRING,
TAXJURCODE TYPE STRING,
TAX_AMOUNT TYPE STRING,
CURRENCY TYPE STRING,
CURREN_ISO TYPE STRING,
AMOUNT_TA TYPE STRING,
CURREN_TA TYPE STRING,
CURRTA_ISO TYPE STRING,END OF T_EKKO_STR. DATA: WA_E1BPPCLOG_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_E1BPPCLOG_STR-PC_LINE sy-vline
WA_E1BPPCLOG_STR-PO_NUMBER sy-vline
WA_E1BPPCLOG_STR-PO_ITEM sy-vline
WA_E1BPPCLOG_STR-SD_DOC sy-vline
WA_E1BPPCLOG_STR-ITM_NUMBER sy-vline
WA_E1BPPCLOG_STR-SHORT_TEXT sy-vline
WA_E1BPPCLOG_STR-COM_CODE sy-vline
WA_E1BPPCLOG_STR-EAN_UPC sy-vline
WA_E1BPPCLOG_STR-QUANTITY sy-vline
WA_E1BPPCLOG_STR-PO_UNIT sy-vline
WA_E1BPPCLOG_STR-POUNIT_ISO sy-vline
WA_E1BPPCLOG_STR-INV_QTY sy-vline
WA_E1BPPCLOG_STR-SALES_UNIT sy-vline
WA_E1BPPCLOG_STR-S_UNIT_ISO sy-vline
WA_E1BPPCLOG_STR-TAX_CODE sy-vline
WA_E1BPPCLOG_STR-TAXJURCODE sy-vline
WA_E1BPPCLOG_STR-TAX_AMOUNT sy-vline
WA_E1BPPCLOG_STR-CURRENCY sy-vline
WA_E1BPPCLOG_STR-CURREN_ISO sy-vline
WA_E1BPPCLOG_STR-AMOUNT_TA sy-vline
WA_E1BPPCLOG_STR-CURREN_TA sy-vline
WA_E1BPPCLOG_STR-CURRTA_ISO sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.