ABAP Select data from SAP table E1BPE1MLGNX into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP E1BPE1MLGNX table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to E1BPE1MLGNX. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the E1BPE1MLGNX table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_E1BPE1MLGNX TYPE STANDARD TABLE OF E1BPE1MLGNX,
      WA_E1BPE1MLGNX TYPE E1BPE1MLGNX,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <E1BPE1MLGNX> TYPE E1BPE1MLGNX.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_E1BPE1MLGNX.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM E1BPE1MLGNX
  INTO TABLE IT_E1BPE1MLGNX.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM E1BPE1MLGNX
*  INTO TABLE @DATA(IT_E1BPE1MLGNX2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_E1BPE1MLGNX INDEX 1 INTO DATA(WA_E1BPE1MLGNX2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_E1BPE1MLGNX ASSIGNING <E1BPE1MLGNX>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<E1BPE1MLGNX>-FUNCTION = 1.
<E1BPE1MLGNX>-MATERIAL = 1.
<E1BPE1MLGNX>-WHSE_NO = 1.
<E1BPE1MLGNX>-DEL_FLAG = 1.
<E1BPE1MLGNX>-STGESECTOR = 1.
ENDLOOP.

LOOP AT IT_E1BPE1MLGNX INTO WA_E1BPE1MLGNX.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_E1BPE1MLGNX-PLACEMENT, sy-vline,
WA_E1BPE1MLGNX-WITHDRAWAL, sy-vline,
WA_E1BPE1MLGNX-L_EQUIP_1, sy-vline,
WA_E1BPE1MLGNX-L_EQUIP_2, sy-vline,
WA_E1BPE1MLGNX-L_EQUIP_3, sy-vline,
WA_E1BPE1MLGNX-LEQ_UNIT_1, sy-vline.
ENDLOOP. *Add any further fields from structure WA_E1BPE1MLGNX you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_E1BPE1MLGNX TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_E1BPE1MLGNX INTO WA_E1BPE1MLGNX. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_E1BPE1MLGNX_STR,
FUNCTION TYPE STRING,
MATERIAL TYPE STRING,
WHSE_NO TYPE STRING,
DEL_FLAG TYPE STRING,
STGESECTOR TYPE STRING,
PLACEMENT TYPE STRING,
WITHDRAWAL TYPE STRING,
L_EQUIP_1 TYPE STRING,
L_EQUIP_2 TYPE STRING,
L_EQUIP_3 TYPE STRING,
LEQ_UNIT_1 TYPE STRING,
LEQ_UNIT_1_ISO TYPE STRING,
LEQ_UNIT_2 TYPE STRING,
LEQ_UNIT_2_ISO TYPE STRING,
LEQ_UNIT_3 TYPE STRING,
LEQ_UNIT_3_ISO TYPE STRING,
UNITTYPE_1 TYPE STRING,
UNITTYPE_2 TYPE STRING,
UNITTYPE_3 TYPE STRING,
WM_UNIT TYPE STRING,
WM_UNIT_ISO TYPE STRING,
ADD_TO_STK TYPE STRING,
BLOCK_STGE TYPE STRING,
MSG_TO_IM TYPE STRING,
SPEC_MVMT TYPE STRING,
CAPY_USAGE TYPE STRING,
PROCURE_UN TYPE STRING,
PROCURE_UN_ISO TYPE STRING,
STGE_TYPE TYPE STRING,
REF_UNIT TYPE STRING,
2STEP_PICK TYPE STRING,
MATERIAL_EXTERNAL TYPE STRING,
MATERIAL_GUID TYPE STRING,
MATERIAL_VERSION TYPE STRING,
MATERIAL_LONG TYPE STRING,END OF T_EKKO_STR. DATA: WA_E1BPE1MLGNX_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_E1BPE1MLGNX_STR-FUNCTION sy-vline
WA_E1BPE1MLGNX_STR-MATERIAL sy-vline
WA_E1BPE1MLGNX_STR-WHSE_NO sy-vline
WA_E1BPE1MLGNX_STR-DEL_FLAG sy-vline
WA_E1BPE1MLGNX_STR-STGESECTOR sy-vline
WA_E1BPE1MLGNX_STR-PLACEMENT sy-vline
WA_E1BPE1MLGNX_STR-WITHDRAWAL sy-vline
WA_E1BPE1MLGNX_STR-L_EQUIP_1 sy-vline
WA_E1BPE1MLGNX_STR-L_EQUIP_2 sy-vline
WA_E1BPE1MLGNX_STR-L_EQUIP_3 sy-vline
WA_E1BPE1MLGNX_STR-LEQ_UNIT_1 sy-vline
WA_E1BPE1MLGNX_STR-LEQ_UNIT_1_ISO sy-vline
WA_E1BPE1MLGNX_STR-LEQ_UNIT_2 sy-vline
WA_E1BPE1MLGNX_STR-LEQ_UNIT_2_ISO sy-vline
WA_E1BPE1MLGNX_STR-LEQ_UNIT_3 sy-vline
WA_E1BPE1MLGNX_STR-LEQ_UNIT_3_ISO sy-vline
WA_E1BPE1MLGNX_STR-UNITTYPE_1 sy-vline
WA_E1BPE1MLGNX_STR-UNITTYPE_2 sy-vline
WA_E1BPE1MLGNX_STR-UNITTYPE_3 sy-vline
WA_E1BPE1MLGNX_STR-WM_UNIT sy-vline
WA_E1BPE1MLGNX_STR-WM_UNIT_ISO sy-vline
WA_E1BPE1MLGNX_STR-ADD_TO_STK sy-vline
WA_E1BPE1MLGNX_STR-BLOCK_STGE sy-vline
WA_E1BPE1MLGNX_STR-MSG_TO_IM sy-vline
WA_E1BPE1MLGNX_STR-SPEC_MVMT sy-vline
WA_E1BPE1MLGNX_STR-CAPY_USAGE sy-vline
WA_E1BPE1MLGNX_STR-PROCURE_UN sy-vline
WA_E1BPE1MLGNX_STR-PROCURE_UN_ISO sy-vline
WA_E1BPE1MLGNX_STR-STGE_TYPE sy-vline
WA_E1BPE1MLGNX_STR-REF_UNIT sy-vline
WA_E1BPE1MLGNX_STR-2STEP_PICK sy-vline
WA_E1BPE1MLGNX_STR-MATERIAL_EXTERNAL sy-vline
WA_E1BPE1MLGNX_STR-MATERIAL_GUID sy-vline
WA_E1BPE1MLGNX_STR-MATERIAL_VERSION sy-vline
WA_E1BPE1MLGNX_STR-MATERIAL_LONG sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.