ABAP Select data from SAP table E1BPE1MBEWRT into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP E1BPE1MBEWRT table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to E1BPE1MBEWRT. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the E1BPE1MBEWRT table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_E1BPE1MBEWRT TYPE STANDARD TABLE OF E1BPE1MBEWRT,
      WA_E1BPE1MBEWRT TYPE E1BPE1MBEWRT,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <E1BPE1MBEWRT> TYPE E1BPE1MBEWRT.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_E1BPE1MBEWRT.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM E1BPE1MBEWRT
  INTO TABLE IT_E1BPE1MBEWRT.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM E1BPE1MBEWRT
*  INTO TABLE @DATA(IT_E1BPE1MBEWRT2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_E1BPE1MBEWRT INDEX 1 INTO DATA(WA_E1BPE1MBEWRT2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_E1BPE1MBEWRT ASSIGNING <E1BPE1MBEWRT>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<E1BPE1MBEWRT>-FUNCTION = 1.
<E1BPE1MBEWRT>-MATERIAL = 1.
<E1BPE1MBEWRT>-VAL_AREA = 1.
<E1BPE1MBEWRT>-VAL_TYPE = 1.
<E1BPE1MBEWRT>-DEL_FLAG = 1.
ENDLOOP.

LOOP AT IT_E1BPE1MBEWRT INTO WA_E1BPE1MBEWRT.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_E1BPE1MBEWRT-PRICE_CTRL, sy-vline,
WA_E1BPE1MBEWRT-MOVING_PR, sy-vline,
WA_E1BPE1MBEWRT-STD_PRICE, sy-vline,
WA_E1BPE1MBEWRT-PRICE_UNIT, sy-vline,
WA_E1BPE1MBEWRT-VAL_CLASS, sy-vline,
WA_E1BPE1MBEWRT-PR_CTRL_PP, sy-vline.
ENDLOOP. *Add any further fields from structure WA_E1BPE1MBEWRT you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_E1BPE1MBEWRT TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_E1BPE1MBEWRT INTO WA_E1BPE1MBEWRT. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_E1BPE1MBEWRT_STR,
FUNCTION TYPE STRING,
MATERIAL TYPE STRING,
VAL_AREA TYPE STRING,
VAL_TYPE TYPE STRING,
DEL_FLAG TYPE STRING,
PRICE_CTRL TYPE STRING,
MOVING_PR TYPE STRING,
STD_PRICE TYPE STRING,
PRICE_UNIT TYPE STRING,
VAL_CLASS TYPE STRING,
PR_CTRL_PP TYPE STRING,
MOV_PR_PP TYPE STRING,
STD_PR_PP TYPE STRING,
PR_UNIT_PP TYPE STRING,
VCLASS_PP TYPE STRING,
PR_CTRL_PY TYPE STRING,
MOV_PR_PY TYPE STRING,
STD_PR_PY TYPE STRING,
PR_UNIT_PY TYPE STRING,
VCLASS_PY TYPE STRING,
VAL_CAT TYPE STRING,
FUTURE_PR TYPE STRING,
VALID_FROM TYPE STRING,
TAXPRICE_1 TYPE STRING,
COMMPRICE1 TYPE STRING,
TAXPRICE_3 TYPE STRING,
COMMPRICE3 TYPE STRING,
LIFO_FIFO TYPE STRING,
POOLNUMBER TYPE STRING,
TAXPRICE_2 TYPE STRING,
COMMPRICE2 TYPE STRING,
DEVAL_IND TYPE STRING,
ML_ACTIVE TYPE STRING,
ML_SETTLE TYPE STRING,
VAL_MARGIN TYPE STRING,
VM_SO_STK TYPE STRING,
VM_P_STOCK TYPE STRING,
MATL_USAGE TYPE STRING,
MAT_ORIGIN TYPE STRING,
IN_HOUSE TYPE STRING,
TAX_CML_UN TYPE STRING,
ORIG_GROUP TYPE STRING,
ORIG_MAT TYPE STRING,
OVERHEAD_GRP TYPE STRING,
WITH_QTY_STRUCT TYPE STRING,
PLND_PRICE TYPE STRING,
PLNDPRICE1 TYPE STRING,
PLNDPRICE2 TYPE STRING,
PLNDPRICE3 TYPE STRING,
PLNDPRDATE1 TYPE STRING,
PLNDPRDATE2 TYPE STRING,
PLNDPRDATE3 TYPE STRING,
MATERIAL_EXTERNAL TYPE STRING,
MATERIAL_GUID TYPE STRING,
MATERIAL_VERSION TYPE STRING,
MATERIAL_LONG TYPE STRING,END OF T_EKKO_STR. DATA: WA_E1BPE1MBEWRT_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_E1BPE1MBEWRT_STR-FUNCTION sy-vline
WA_E1BPE1MBEWRT_STR-MATERIAL sy-vline
WA_E1BPE1MBEWRT_STR-VAL_AREA sy-vline
WA_E1BPE1MBEWRT_STR-VAL_TYPE sy-vline
WA_E1BPE1MBEWRT_STR-DEL_FLAG sy-vline
WA_E1BPE1MBEWRT_STR-PRICE_CTRL sy-vline
WA_E1BPE1MBEWRT_STR-MOVING_PR sy-vline
WA_E1BPE1MBEWRT_STR-STD_PRICE sy-vline
WA_E1BPE1MBEWRT_STR-PRICE_UNIT sy-vline
WA_E1BPE1MBEWRT_STR-VAL_CLASS sy-vline
WA_E1BPE1MBEWRT_STR-PR_CTRL_PP sy-vline
WA_E1BPE1MBEWRT_STR-MOV_PR_PP sy-vline
WA_E1BPE1MBEWRT_STR-STD_PR_PP sy-vline
WA_E1BPE1MBEWRT_STR-PR_UNIT_PP sy-vline
WA_E1BPE1MBEWRT_STR-VCLASS_PP sy-vline
WA_E1BPE1MBEWRT_STR-PR_CTRL_PY sy-vline
WA_E1BPE1MBEWRT_STR-MOV_PR_PY sy-vline
WA_E1BPE1MBEWRT_STR-STD_PR_PY sy-vline
WA_E1BPE1MBEWRT_STR-PR_UNIT_PY sy-vline
WA_E1BPE1MBEWRT_STR-VCLASS_PY sy-vline
WA_E1BPE1MBEWRT_STR-VAL_CAT sy-vline
WA_E1BPE1MBEWRT_STR-FUTURE_PR sy-vline
WA_E1BPE1MBEWRT_STR-VALID_FROM sy-vline
WA_E1BPE1MBEWRT_STR-TAXPRICE_1 sy-vline
WA_E1BPE1MBEWRT_STR-COMMPRICE1 sy-vline
WA_E1BPE1MBEWRT_STR-TAXPRICE_3 sy-vline
WA_E1BPE1MBEWRT_STR-COMMPRICE3 sy-vline
WA_E1BPE1MBEWRT_STR-LIFO_FIFO sy-vline
WA_E1BPE1MBEWRT_STR-POOLNUMBER sy-vline
WA_E1BPE1MBEWRT_STR-TAXPRICE_2 sy-vline
WA_E1BPE1MBEWRT_STR-COMMPRICE2 sy-vline
WA_E1BPE1MBEWRT_STR-DEVAL_IND sy-vline
WA_E1BPE1MBEWRT_STR-ML_ACTIVE sy-vline
WA_E1BPE1MBEWRT_STR-ML_SETTLE sy-vline
WA_E1BPE1MBEWRT_STR-VAL_MARGIN sy-vline
WA_E1BPE1MBEWRT_STR-VM_SO_STK sy-vline
WA_E1BPE1MBEWRT_STR-VM_P_STOCK sy-vline
WA_E1BPE1MBEWRT_STR-MATL_USAGE sy-vline
WA_E1BPE1MBEWRT_STR-MAT_ORIGIN sy-vline
WA_E1BPE1MBEWRT_STR-IN_HOUSE sy-vline
WA_E1BPE1MBEWRT_STR-TAX_CML_UN sy-vline
WA_E1BPE1MBEWRT_STR-ORIG_GROUP sy-vline
WA_E1BPE1MBEWRT_STR-ORIG_MAT sy-vline
WA_E1BPE1MBEWRT_STR-OVERHEAD_GRP sy-vline
WA_E1BPE1MBEWRT_STR-WITH_QTY_STRUCT sy-vline
WA_E1BPE1MBEWRT_STR-PLND_PRICE sy-vline
WA_E1BPE1MBEWRT_STR-PLNDPRICE1 sy-vline
WA_E1BPE1MBEWRT_STR-PLNDPRICE2 sy-vline
WA_E1BPE1MBEWRT_STR-PLNDPRICE3 sy-vline
WA_E1BPE1MBEWRT_STR-PLNDPRDATE1 sy-vline
WA_E1BPE1MBEWRT_STR-PLNDPRDATE2 sy-vline
WA_E1BPE1MBEWRT_STR-PLNDPRDATE3 sy-vline
WA_E1BPE1MBEWRT_STR-MATERIAL_EXTERNAL sy-vline
WA_E1BPE1MBEWRT_STR-MATERIAL_GUID sy-vline
WA_E1BPE1MBEWRT_STR-MATERIAL_VERSION sy-vline
WA_E1BPE1MBEWRT_STR-MATERIAL_LONG sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.