ABAP Select data from SAP table E1BPE1MARM into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP E1BPE1MARM table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to E1BPE1MARM. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the E1BPE1MARM table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_E1BPE1MARM TYPE STANDARD TABLE OF E1BPE1MARM,
      WA_E1BPE1MARM TYPE E1BPE1MARM,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <E1BPE1MARM> TYPE E1BPE1MARM.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_E1BPE1MARM.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM E1BPE1MARM
  INTO TABLE IT_E1BPE1MARM.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM E1BPE1MARM
*  INTO TABLE @DATA(IT_E1BPE1MARM2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_E1BPE1MARM INDEX 1 INTO DATA(WA_E1BPE1MARM2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_E1BPE1MARM ASSIGNING <E1BPE1MARM>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<E1BPE1MARM>-FUNCTION = 1.
<E1BPE1MARM>-MATERIAL = 1.
<E1BPE1MARM>-ALT_UNIT = 1.
<E1BPE1MARM>-ALT_UNIT_ISO = 1.
<E1BPE1MARM>-NUMERATOR = 1.
ENDLOOP.

LOOP AT IT_E1BPE1MARM INTO WA_E1BPE1MARM.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_E1BPE1MARM-DENOMINATR, sy-vline,
WA_E1BPE1MARM-EAN_UPC, sy-vline,
WA_E1BPE1MARM-EAN_CAT, sy-vline,
WA_E1BPE1MARM-LENGTH, sy-vline,
WA_E1BPE1MARM-WIDTH, sy-vline,
WA_E1BPE1MARM-HEIGHT, sy-vline.
ENDLOOP. *Add any further fields from structure WA_E1BPE1MARM you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_E1BPE1MARM TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_E1BPE1MARM INTO WA_E1BPE1MARM. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_E1BPE1MARM_STR,
FUNCTION TYPE STRING,
MATERIAL TYPE STRING,
ALT_UNIT TYPE STRING,
ALT_UNIT_ISO TYPE STRING,
NUMERATOR TYPE STRING,
DENOMINATR TYPE STRING,
EAN_UPC TYPE STRING,
EAN_CAT TYPE STRING,
LENGTH TYPE STRING,
WIDTH TYPE STRING,
HEIGHT TYPE STRING,
UNIT_DIM TYPE STRING,
UNIT_DIM_ISO TYPE STRING,
VOLUME TYPE STRING,
VOLUMEUNIT TYPE STRING,
VOLUMEUNIT_ISO TYPE STRING,
GROSS_WT TYPE STRING,
UNIT_OF_WT TYPE STRING,
UNIT_OF_WT_ISO TYPE STRING,
DEL_FLAG TYPE STRING,
SUB_UOM TYPE STRING,
SUB_UOM_ISO TYPE STRING,
GTIN_VARIANT TYPE STRING,
MATERIAL_EXTERNAL TYPE STRING,
MATERIAL_GUID TYPE STRING,
MATERIAL_VERSION TYPE STRING,
NESTING_FACTOR TYPE STRING,
MAXIMUM_STACKING TYPE STRING,
CAPACITY_USAGE TYPE STRING,
EWM_CW_UOM_TYPE TYPE STRING,
MATERIAL_LONG TYPE STRING,END OF T_EKKO_STR. DATA: WA_E1BPE1MARM_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_E1BPE1MARM_STR-FUNCTION sy-vline
WA_E1BPE1MARM_STR-MATERIAL sy-vline
WA_E1BPE1MARM_STR-ALT_UNIT sy-vline
WA_E1BPE1MARM_STR-ALT_UNIT_ISO sy-vline
WA_E1BPE1MARM_STR-NUMERATOR sy-vline
WA_E1BPE1MARM_STR-DENOMINATR sy-vline
WA_E1BPE1MARM_STR-EAN_UPC sy-vline
WA_E1BPE1MARM_STR-EAN_CAT sy-vline
WA_E1BPE1MARM_STR-LENGTH sy-vline
WA_E1BPE1MARM_STR-WIDTH sy-vline
WA_E1BPE1MARM_STR-HEIGHT sy-vline
WA_E1BPE1MARM_STR-UNIT_DIM sy-vline
WA_E1BPE1MARM_STR-UNIT_DIM_ISO sy-vline
WA_E1BPE1MARM_STR-VOLUME sy-vline
WA_E1BPE1MARM_STR-VOLUMEUNIT sy-vline
WA_E1BPE1MARM_STR-VOLUMEUNIT_ISO sy-vline
WA_E1BPE1MARM_STR-GROSS_WT sy-vline
WA_E1BPE1MARM_STR-UNIT_OF_WT sy-vline
WA_E1BPE1MARM_STR-UNIT_OF_WT_ISO sy-vline
WA_E1BPE1MARM_STR-DEL_FLAG sy-vline
WA_E1BPE1MARM_STR-SUB_UOM sy-vline
WA_E1BPE1MARM_STR-SUB_UOM_ISO sy-vline
WA_E1BPE1MARM_STR-GTIN_VARIANT sy-vline
WA_E1BPE1MARM_STR-MATERIAL_EXTERNAL sy-vline
WA_E1BPE1MARM_STR-MATERIAL_GUID sy-vline
WA_E1BPE1MARM_STR-MATERIAL_VERSION sy-vline
WA_E1BPE1MARM_STR-NESTING_FACTOR sy-vline
WA_E1BPE1MARM_STR-MAXIMUM_STACKING sy-vline
WA_E1BPE1MARM_STR-CAPACITY_USAGE sy-vline
WA_E1BPE1MARM_STR-EWM_CW_UOM_TYPE sy-vline
WA_E1BPE1MARM_STR-MATERIAL_LONG sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.