ABAP Select data from SAP table E1BPBUSISM008_SL_CMX into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP E1BPBUSISM008_SL_CMX table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to E1BPBUSISM008_SL_CMX. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the E1BPBUSISM008_SL_CMX table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_E1BPBUSISM008_SL_CMX TYPE STANDARD TABLE OF E1BPBUSISM008_SL_CMX,
      WA_E1BPBUSISM008_SL_CMX TYPE E1BPBUSISM008_SL_CMX,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <E1BPBUSISM008_SL_CMX> TYPE E1BPBUSISM008_SL_CMX.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_E1BPBUSISM008_SL_CMX.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM E1BPBUSISM008_SL_CMX
  INTO TABLE IT_E1BPBUSISM008_SL_CMX.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM E1BPBUSISM008_SL_CMX
*  INTO TABLE @DATA(IT_E1BPBUSISM008_SL_CMX2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_E1BPBUSISM008_SL_CMX INDEX 1 INTO DATA(WA_E1BPBUSISM008_SL_CMX2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_E1BPBUSISM008_SL_CMX ASSIGNING <E1BPBUSISM008_SL_CMX>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<E1BPBUSISM008_SL_CMX>-DOCUMENT_NO = 1.
<E1BPBUSISM008_SL_CMX>-ITEM_NUMBER = 1.
<E1BPBUSISM008_SL_CMX>-SUB_ITEM_NO = 1.
<E1BPBUSISM008_SL_CMX>-SCHEDULE_LINE_NO = 1.
<E1BPBUSISM008_SL_CMX>-UPDATEFLAG = 1.
ENDLOOP.

LOOP AT IT_E1BPBUSISM008_SL_CMX INTO WA_E1BPBUSISM008_SL_CMX.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_E1BPBUSISM008_SL_CMX-ACTUAL_PUBLICATION_DATE, sy-vline,
WA_E1BPBUSISM008_SL_CMX-ACTUAL_COMMERCIAL_TIMESLICE, sy-vline,
WA_E1BPBUSISM008_SL_CMX-ACTUAL_COMMERCIAL_CLUSTER, sy-vline,
WA_E1BPBUSISM008_SL_CMX-ACTUAL_COMMERCIAL_POSITION, sy-vline,
WA_E1BPBUSISM008_SL_CMX-COMMERCIAL_BROADCAST, sy-vline,
WA_E1BPBUSISM008_SL_CMX-COMMERCIAL_RATE_GROUP, sy-vline.
ENDLOOP. *Add any further fields from structure WA_E1BPBUSISM008_SL_CMX you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_E1BPBUSISM008_SL_CMX TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_E1BPBUSISM008_SL_CMX INTO WA_E1BPBUSISM008_SL_CMX. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_E1BPBUSISM008_SL_CMX_STR,
DOCUMENT_NO TYPE STRING,
ITEM_NUMBER TYPE STRING,
SUB_ITEM_NO TYPE STRING,
SCHEDULE_LINE_NO TYPE STRING,
UPDATEFLAG TYPE STRING,
ACTUAL_PUBLICATION_DATE TYPE STRING,
ACTUAL_COMMERCIAL_TIMESLICE TYPE STRING,
ACTUAL_COMMERCIAL_CLUSTER TYPE STRING,
ACTUAL_COMMERCIAL_POSITION TYPE STRING,
COMMERCIAL_BROADCAST TYPE STRING,
COMMERCIAL_RATE_GROUP TYPE STRING,
AD_SPEC_NO TYPE STRING,
PUBLISHED TYPE STRING,
STATUS_CHARACTERISTIC0 TYPE STRING,
STATUS_CHARACTERISTIC1 TYPE STRING,
STATUS_CHARACTERISTIC2 TYPE STRING,
STATUS_CHARACTERISTIC3 TYPE STRING,
STATUS_CHARACTERISTIC4 TYPE STRING,
STATUS_CHARACTERISTIC5 TYPE STRING,
STATUS_CHARACTERISTIC6 TYPE STRING,
STATUS_CHARACTERISTIC7 TYPE STRING,
STATUS_CHARACTERISTIC8 TYPE STRING,
STATUS_CHARACTERISTIC9 TYPE STRING,END OF T_EKKO_STR. DATA: WA_E1BPBUSISM008_SL_CMX_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_E1BPBUSISM008_SL_CMX_STR-DOCUMENT_NO sy-vline
WA_E1BPBUSISM008_SL_CMX_STR-ITEM_NUMBER sy-vline
WA_E1BPBUSISM008_SL_CMX_STR-SUB_ITEM_NO sy-vline
WA_E1BPBUSISM008_SL_CMX_STR-SCHEDULE_LINE_NO sy-vline
WA_E1BPBUSISM008_SL_CMX_STR-UPDATEFLAG sy-vline
WA_E1BPBUSISM008_SL_CMX_STR-ACTUAL_PUBLICATION_DATE sy-vline
WA_E1BPBUSISM008_SL_CMX_STR-ACTUAL_COMMERCIAL_TIMESLICE sy-vline
WA_E1BPBUSISM008_SL_CMX_STR-ACTUAL_COMMERCIAL_CLUSTER sy-vline
WA_E1BPBUSISM008_SL_CMX_STR-ACTUAL_COMMERCIAL_POSITION sy-vline
WA_E1BPBUSISM008_SL_CMX_STR-COMMERCIAL_BROADCAST sy-vline
WA_E1BPBUSISM008_SL_CMX_STR-COMMERCIAL_RATE_GROUP sy-vline
WA_E1BPBUSISM008_SL_CMX_STR-AD_SPEC_NO sy-vline
WA_E1BPBUSISM008_SL_CMX_STR-PUBLISHED sy-vline
WA_E1BPBUSISM008_SL_CMX_STR-STATUS_CHARACTERISTIC0 sy-vline
WA_E1BPBUSISM008_SL_CMX_STR-STATUS_CHARACTERISTIC1 sy-vline
WA_E1BPBUSISM008_SL_CMX_STR-STATUS_CHARACTERISTIC2 sy-vline
WA_E1BPBUSISM008_SL_CMX_STR-STATUS_CHARACTERISTIC3 sy-vline
WA_E1BPBUSISM008_SL_CMX_STR-STATUS_CHARACTERISTIC4 sy-vline
WA_E1BPBUSISM008_SL_CMX_STR-STATUS_CHARACTERISTIC5 sy-vline
WA_E1BPBUSISM008_SL_CMX_STR-STATUS_CHARACTERISTIC6 sy-vline
WA_E1BPBUSISM008_SL_CMX_STR-STATUS_CHARACTERISTIC7 sy-vline
WA_E1BPBUSISM008_SL_CMX_STR-STATUS_CHARACTERISTIC8 sy-vline
WA_E1BPBUSISM008_SL_CMX_STR-STATUS_CHARACTERISTIC9 sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.