ABAP Select data from SAP table E1BP_RE_BUILDING_DAT into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP E1BP_RE_BUILDING_DAT table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to E1BP_RE_BUILDING_DAT. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the E1BP_RE_BUILDING_DAT table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_E1BP_RE_BUILDING_DAT TYPE STANDARD TABLE OF E1BP_RE_BUILDING_DAT,
      WA_E1BP_RE_BUILDING_DAT TYPE E1BP_RE_BUILDING_DAT,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <E1BP_RE_BUILDING_DAT> TYPE E1BP_RE_BUILDING_DAT.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_E1BP_RE_BUILDING_DAT.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM E1BP_RE_BUILDING_DAT
  INTO TABLE IT_E1BP_RE_BUILDING_DAT.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM E1BP_RE_BUILDING_DAT
*  INTO TABLE @DATA(IT_E1BP_RE_BUILDING_DAT2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_E1BP_RE_BUILDING_DAT INDEX 1 INTO DATA(WA_E1BP_RE_BUILDING_DAT2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_E1BP_RE_BUILDING_DAT ASSIGNING <E1BP_RE_BUILDING_DAT>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<E1BP_RE_BUILDING_DAT>-BUILDING_TEXT = 1.
<E1BP_RE_BUILDING_DAT>-BUILDING_TYPE = 1.
<E1BP_RE_BUILDING_DAT>-BUILDING_CONDITION = 1.
<E1BP_RE_BUILDING_DAT>-CONSTRUCTION_YEAR = 1.
<E1BP_RE_BUILDING_DAT>-MODERNIZATION_YEAR = 1.
ENDLOOP.

LOOP AT IT_E1BP_RE_BUILDING_DAT INTO WA_E1BP_RE_BUILDING_DAT.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_E1BP_RE_BUILDING_DAT-RECONSTRUCTION_YEAR, sy-vline,
WA_E1BP_RE_BUILDING_DAT-BEGIN_CONSTRUCTION_YEAR, sy-vline,
WA_E1BP_RE_BUILDING_DAT-READY_FOR_OCCUPANCY_DATE, sy-vline,
WA_E1BP_RE_BUILDING_DAT-COMPLETION_DATE, sy-vline,
WA_E1BP_RE_BUILDING_DAT-FINAL_INSPECTION_DATE, sy-vline,
WA_E1BP_RE_BUILDING_DAT-PLANNING_INQUIRY_DATE, sy-vline.
ENDLOOP. *Add any further fields from structure WA_E1BP_RE_BUILDING_DAT you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_E1BP_RE_BUILDING_DAT TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_E1BP_RE_BUILDING_DAT INTO WA_E1BP_RE_BUILDING_DAT. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_E1BP_RE_BUILDING_DAT_STR,
BUILDING_TEXT TYPE STRING,
BUILDING_TYPE TYPE STRING,
BUILDING_CONDITION TYPE STRING,
CONSTRUCTION_YEAR TYPE STRING,
MODERNIZATION_YEAR TYPE STRING,
RECONSTRUCTION_YEAR TYPE STRING,
BEGIN_CONSTRUCTION_YEAR TYPE STRING,
READY_FOR_OCCUPANCY_DATE TYPE STRING,
COMPLETION_DATE TYPE STRING,
FINAL_INSPECTION_DATE TYPE STRING,
PLANNING_INQUIRY_DATE TYPE STRING,
PRIOR_NOTICE_DATE TYPE STRING,
BUILDING_PERMIT_APPLIC_DATE TYPE STRING,
BUILDING_PERMIT_DATE TYPE STRING,
TRANSF_USE_AND_ENCUMBR_DATE TYPE STRING,
SALE_DATE TYPE STRING,
PLANNED_SALE_DATE TYPE STRING,
USAGE_END_DATE TYPE STRING,
BUILDING_PERMIT_NOTE TYPE STRING,
BUILDING_VALUE TYPE STRING,
CURRENT_BUILDING_VALUE TYPE STRING,
AMOUNT_PER_VOLUME TYPE STRING,
HAS_HIST_SITE_PROTECTION TYPE STRING,
ASSESSMENT_VALUE TYPE STRING,
ASSESSMENT_VALUE_YEAR TYPE STRING,
INSURANCE_VALUE TYPE STRING,
INSURANCE_VALUE_TYPE TYPE STRING,
HERITABLE_BLDG_RIGHT_IND TYPE STRING,
LOCATION_CLASS TYPE STRING,
MAIN_USAGE_TYPE TYPE STRING,
PUBLIC_FUNDING_FROM TYPE STRING,
PUBLIC_FUNDING_TO TYPE STRING,
FLOORS TYPE STRING,
BASEMENTS TYPE STRING,
TOP_FLOOR TYPE STRING,
ELEVATOR_TO_FLOOR TYPE STRING,
MUNICIPALITY_KEY TYPE STRING,
HAS_CURR_OCC_PRINC TYPE STRING,
UNIT_VOLUME TYPE STRING,
UNIT_VOLUME_ISO TYPE STRING,
CURRENCY TYPE STRING,
CURRENCY_ISO TYPE STRING,
AUTHORIZATION_GROUP TYPE STRING,
OBJECT_VALID_FROM TYPE STRING,
OBJECT_VALID_TO TYPE STRING,
RESPONSIBLE TYPE STRING,
STAT_PROF TYPE STRING,
MANDATE_OBJECT_ID TYPE STRING,
MANDATE_MNG_OBJECT_ID TYPE STRING,
MANDATE_CR_OBJECT_ID TYPE STRING,
USES_REPR_LIST_OF_RENTS TYPE STRING,
FUNCTION TYPE STRING,END OF T_EKKO_STR. DATA: WA_E1BP_RE_BUILDING_DAT_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_E1BP_RE_BUILDING_DAT_STR-BUILDING_TEXT sy-vline
WA_E1BP_RE_BUILDING_DAT_STR-BUILDING_TYPE sy-vline
WA_E1BP_RE_BUILDING_DAT_STR-BUILDING_CONDITION sy-vline
WA_E1BP_RE_BUILDING_DAT_STR-CONSTRUCTION_YEAR sy-vline
WA_E1BP_RE_BUILDING_DAT_STR-MODERNIZATION_YEAR sy-vline
WA_E1BP_RE_BUILDING_DAT_STR-RECONSTRUCTION_YEAR sy-vline
WA_E1BP_RE_BUILDING_DAT_STR-BEGIN_CONSTRUCTION_YEAR sy-vline
WA_E1BP_RE_BUILDING_DAT_STR-READY_FOR_OCCUPANCY_DATE sy-vline
WA_E1BP_RE_BUILDING_DAT_STR-COMPLETION_DATE sy-vline
WA_E1BP_RE_BUILDING_DAT_STR-FINAL_INSPECTION_DATE sy-vline
WA_E1BP_RE_BUILDING_DAT_STR-PLANNING_INQUIRY_DATE sy-vline
WA_E1BP_RE_BUILDING_DAT_STR-PRIOR_NOTICE_DATE sy-vline
WA_E1BP_RE_BUILDING_DAT_STR-BUILDING_PERMIT_APPLIC_DATE sy-vline
WA_E1BP_RE_BUILDING_DAT_STR-BUILDING_PERMIT_DATE sy-vline
WA_E1BP_RE_BUILDING_DAT_STR-TRANSF_USE_AND_ENCUMBR_DATE sy-vline
WA_E1BP_RE_BUILDING_DAT_STR-SALE_DATE sy-vline
WA_E1BP_RE_BUILDING_DAT_STR-PLANNED_SALE_DATE sy-vline
WA_E1BP_RE_BUILDING_DAT_STR-USAGE_END_DATE sy-vline
WA_E1BP_RE_BUILDING_DAT_STR-BUILDING_PERMIT_NOTE sy-vline
WA_E1BP_RE_BUILDING_DAT_STR-BUILDING_VALUE sy-vline
WA_E1BP_RE_BUILDING_DAT_STR-CURRENT_BUILDING_VALUE sy-vline
WA_E1BP_RE_BUILDING_DAT_STR-AMOUNT_PER_VOLUME sy-vline
WA_E1BP_RE_BUILDING_DAT_STR-HAS_HIST_SITE_PROTECTION sy-vline
WA_E1BP_RE_BUILDING_DAT_STR-ASSESSMENT_VALUE sy-vline
WA_E1BP_RE_BUILDING_DAT_STR-ASSESSMENT_VALUE_YEAR sy-vline
WA_E1BP_RE_BUILDING_DAT_STR-INSURANCE_VALUE sy-vline
WA_E1BP_RE_BUILDING_DAT_STR-INSURANCE_VALUE_TYPE sy-vline
WA_E1BP_RE_BUILDING_DAT_STR-HERITABLE_BLDG_RIGHT_IND sy-vline
WA_E1BP_RE_BUILDING_DAT_STR-LOCATION_CLASS sy-vline
WA_E1BP_RE_BUILDING_DAT_STR-MAIN_USAGE_TYPE sy-vline
WA_E1BP_RE_BUILDING_DAT_STR-PUBLIC_FUNDING_FROM sy-vline
WA_E1BP_RE_BUILDING_DAT_STR-PUBLIC_FUNDING_TO sy-vline
WA_E1BP_RE_BUILDING_DAT_STR-FLOORS sy-vline
WA_E1BP_RE_BUILDING_DAT_STR-BASEMENTS sy-vline
WA_E1BP_RE_BUILDING_DAT_STR-TOP_FLOOR sy-vline
WA_E1BP_RE_BUILDING_DAT_STR-ELEVATOR_TO_FLOOR sy-vline
WA_E1BP_RE_BUILDING_DAT_STR-MUNICIPALITY_KEY sy-vline
WA_E1BP_RE_BUILDING_DAT_STR-HAS_CURR_OCC_PRINC sy-vline
WA_E1BP_RE_BUILDING_DAT_STR-UNIT_VOLUME sy-vline
WA_E1BP_RE_BUILDING_DAT_STR-UNIT_VOLUME_ISO sy-vline
WA_E1BP_RE_BUILDING_DAT_STR-CURRENCY sy-vline
WA_E1BP_RE_BUILDING_DAT_STR-CURRENCY_ISO sy-vline
WA_E1BP_RE_BUILDING_DAT_STR-AUTHORIZATION_GROUP sy-vline
WA_E1BP_RE_BUILDING_DAT_STR-OBJECT_VALID_FROM sy-vline
WA_E1BP_RE_BUILDING_DAT_STR-OBJECT_VALID_TO sy-vline
WA_E1BP_RE_BUILDING_DAT_STR-RESPONSIBLE sy-vline
WA_E1BP_RE_BUILDING_DAT_STR-STAT_PROF sy-vline
WA_E1BP_RE_BUILDING_DAT_STR-MANDATE_OBJECT_ID sy-vline
WA_E1BP_RE_BUILDING_DAT_STR-MANDATE_MNG_OBJECT_ID sy-vline
WA_E1BP_RE_BUILDING_DAT_STR-MANDATE_CR_OBJECT_ID sy-vline
WA_E1BP_RE_BUILDING_DAT_STR-USES_REPR_LIST_OF_RENTS sy-vline
WA_E1BP_RE_BUILDING_DAT_STR-FUNCTION sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.