ABAP Select data from SAP table E1BP_QCI_PAR into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP E1BP_QCI_PAR table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to E1BP_QCI_PAR. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the E1BP_QCI_PAR table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_E1BP_QCI_PAR TYPE STANDARD TABLE OF E1BP_QCI_PAR,
      WA_E1BP_QCI_PAR TYPE E1BP_QCI_PAR,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <E1BP_QCI_PAR> TYPE E1BP_QCI_PAR.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_E1BP_QCI_PAR.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM E1BP_QCI_PAR
  INTO TABLE IT_E1BP_QCI_PAR.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM E1BP_QCI_PAR
*  INTO TABLE @DATA(IT_E1BP_QCI_PAR2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_E1BP_QCI_PAR INDEX 1 INTO DATA(WA_E1BP_QCI_PAR2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_E1BP_QCI_PAR ASSIGNING <E1BP_QCI_PAR>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<E1BP_QCI_PAR>-COUNTER = 1.
<E1BP_QCI_PAR>-DENS_TYPE = 1.
<E1BP_QCI_PAR>-SHELL_TEMP = 1.
<E1BP_QCI_PAR>-SHELL_TEMP_UOM = 1.
<E1BP_QCI_PAR>-UL_IN_IND = 1.
ENDLOOP.

LOOP AT IT_E1BP_QCI_PAR INTO WA_E1BP_QCI_PAR.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_E1BP_QCI_PAR-TEST_TEMP, sy-vline,
WA_E1BP_QCI_PAR-TEST_TEMP_UOM, sy-vline,
WA_E1BP_QCI_PAR-MAT_TEMP, sy-vline,
WA_E1BP_QCI_PAR-MAT_TEMP_UOM, sy-vline,
WA_E1BP_QCI_PAR-BASE_DENS, sy-vline,
WA_E1BP_QCI_PAR-B_DENS_UOM, sy-vline.
ENDLOOP. *Add any further fields from structure WA_E1BP_QCI_PAR you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_E1BP_QCI_PAR TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_E1BP_QCI_PAR INTO WA_E1BP_QCI_PAR. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_E1BP_QCI_PAR_STR,
COUNTER TYPE STRING,
DENS_TYPE TYPE STRING,
SHELL_TEMP TYPE STRING,
SHELL_TEMP_UOM TYPE STRING,
UL_IN_IND TYPE STRING,
TEST_TEMP TYPE STRING,
TEST_TEMP_UOM TYPE STRING,
MAT_TEMP TYPE STRING,
MAT_TEMP_UOM TYPE STRING,
BASE_DENS TYPE STRING,
B_DENS_UOM TYPE STRING,
TEST_DENS TYPE STRING,
TEST_DENS_UOM TYPE STRING,
FX_DENS TYPE STRING,
FX_DENS_UOM TYPE STRING,
MAT_PRES TYPE STRING,
MAT_PRES_UOM TYPE STRING,
TEST_PRES_DENS TYPE STRING,
TEST_PRES_UOM TYPE STRING,
ATM_PRES TYPE STRING,
ATM_PRES_UOM TYPE STRING,
VAP_PRES TYPE STRING,
VAP_PRES_UOM TYPE STRING,
HYDRO_CORR_IND TYPE STRING,
AB_IND TYPE STRING,
AB_FAC TYPE STRING,
MCF TYPE STRING,
BSW TYPE STRING,
BSW_UOM TYPE STRING,
CONV_GRPL TYPE STRING,
QC_COEFF TYPE STRING,
QCI_MAN_IND TYPE STRING,END OF T_EKKO_STR. DATA: WA_E1BP_QCI_PAR_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_E1BP_QCI_PAR_STR-COUNTER sy-vline
WA_E1BP_QCI_PAR_STR-DENS_TYPE sy-vline
WA_E1BP_QCI_PAR_STR-SHELL_TEMP sy-vline
WA_E1BP_QCI_PAR_STR-SHELL_TEMP_UOM sy-vline
WA_E1BP_QCI_PAR_STR-UL_IN_IND sy-vline
WA_E1BP_QCI_PAR_STR-TEST_TEMP sy-vline
WA_E1BP_QCI_PAR_STR-TEST_TEMP_UOM sy-vline
WA_E1BP_QCI_PAR_STR-MAT_TEMP sy-vline
WA_E1BP_QCI_PAR_STR-MAT_TEMP_UOM sy-vline
WA_E1BP_QCI_PAR_STR-BASE_DENS sy-vline
WA_E1BP_QCI_PAR_STR-B_DENS_UOM sy-vline
WA_E1BP_QCI_PAR_STR-TEST_DENS sy-vline
WA_E1BP_QCI_PAR_STR-TEST_DENS_UOM sy-vline
WA_E1BP_QCI_PAR_STR-FX_DENS sy-vline
WA_E1BP_QCI_PAR_STR-FX_DENS_UOM sy-vline
WA_E1BP_QCI_PAR_STR-MAT_PRES sy-vline
WA_E1BP_QCI_PAR_STR-MAT_PRES_UOM sy-vline
WA_E1BP_QCI_PAR_STR-TEST_PRES_DENS sy-vline
WA_E1BP_QCI_PAR_STR-TEST_PRES_UOM sy-vline
WA_E1BP_QCI_PAR_STR-ATM_PRES sy-vline
WA_E1BP_QCI_PAR_STR-ATM_PRES_UOM sy-vline
WA_E1BP_QCI_PAR_STR-VAP_PRES sy-vline
WA_E1BP_QCI_PAR_STR-VAP_PRES_UOM sy-vline
WA_E1BP_QCI_PAR_STR-HYDRO_CORR_IND sy-vline
WA_E1BP_QCI_PAR_STR-AB_IND sy-vline
WA_E1BP_QCI_PAR_STR-AB_FAC sy-vline
WA_E1BP_QCI_PAR_STR-MCF sy-vline
WA_E1BP_QCI_PAR_STR-BSW sy-vline
WA_E1BP_QCI_PAR_STR-BSW_UOM sy-vline
WA_E1BP_QCI_PAR_STR-CONV_GRPL sy-vline
WA_E1BP_QCI_PAR_STR-QC_COEFF sy-vline
WA_E1BP_QCI_PAR_STR-QCI_MAN_IND sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.