ABAP Select data from SAP table E1BP_PP_TIMEEVENT into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP E1BP_PP_TIMEEVENT table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to E1BP_PP_TIMEEVENT. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the E1BP_PP_TIMEEVENT table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_E1BP_PP_TIMEEVENT TYPE STANDARD TABLE OF E1BP_PP_TIMEEVENT,
      WA_E1BP_PP_TIMEEVENT TYPE E1BP_PP_TIMEEVENT,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <E1BP_PP_TIMEEVENT> TYPE E1BP_PP_TIMEEVENT.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_E1BP_PP_TIMEEVENT.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM E1BP_PP_TIMEEVENT
  INTO TABLE IT_E1BP_PP_TIMEEVENT.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM E1BP_PP_TIMEEVENT
*  INTO TABLE @DATA(IT_E1BP_PP_TIMEEVENT2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_E1BP_PP_TIMEEVENT INDEX 1 INTO DATA(WA_E1BP_PP_TIMEEVENT2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_E1BP_PP_TIMEEVENT ASSIGNING <E1BP_PP_TIMEEVENT>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<E1BP_PP_TIMEEVENT>-CONF_NO = 1.
<E1BP_PP_TIMEEVENT>-ORDERID = 1.
<E1BP_PP_TIMEEVENT>-SEQUENCE = 1.
<E1BP_PP_TIMEEVENT>-OPERATION = 1.
<E1BP_PP_TIMEEVENT>-SUB_OPER = 1.
ENDLOOP.

LOOP AT IT_E1BP_PP_TIMEEVENT INTO WA_E1BP_PP_TIMEEVENT.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_E1BP_PP_TIMEEVENT-CAPA_CATEGORY, sy-vline,
WA_E1BP_PP_TIMEEVENT-SPLIT, sy-vline,
WA_E1BP_PP_TIMEEVENT-RECORDTYPE, sy-vline,
WA_E1BP_PP_TIMEEVENT-LOGDATE, sy-vline,
WA_E1BP_PP_TIMEEVENT-LOGTIME, sy-vline,
WA_E1BP_PP_TIMEEVENT-FIN_CONF, sy-vline.
ENDLOOP. *Add any further fields from structure WA_E1BP_PP_TIMEEVENT you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_E1BP_PP_TIMEEVENT TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_E1BP_PP_TIMEEVENT INTO WA_E1BP_PP_TIMEEVENT. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_E1BP_PP_TIMEEVENT_STR,
CONF_NO TYPE STRING,
ORDERID TYPE STRING,
SEQUENCE TYPE STRING,
OPERATION TYPE STRING,
SUB_OPER TYPE STRING,
CAPA_CATEGORY TYPE STRING,
SPLIT TYPE STRING,
RECORDTYPE TYPE STRING,
LOGDATE TYPE STRING,
LOGTIME TYPE STRING,
FIN_CONF TYPE STRING,
CLEAR_RES TYPE STRING,
POSTG_DATE TYPE STRING,
DEV_REASON TYPE STRING,
CONF_TEXT TYPE STRING,
CONF_QUAN_UNIT TYPE STRING,
CONF_QUAN_UNIT_ISO TYPE STRING,
YIELD TYPE STRING,
SCRAP TYPE STRING,
REWORK TYPE STRING,
PLANT TYPE STRING,
WORK_CNTR TYPE STRING,
CONF_ACTI_UNIT1 TYPE STRING,
CONF_ACTI_UNIT1_ISO TYPE STRING,
CONF_ACTIVITY1 TYPE STRING,
NO_REMN_ACTI1 TYPE STRING,
CONF_ACTI_UNIT2 TYPE STRING,
CONF_ACTI_UNIT2_ISO TYPE STRING,
CONF_ACTIVITY2 TYPE STRING,
NO_REMN_ACTI2 TYPE STRING,
CONF_ACTI_UNIT3 TYPE STRING,
CONF_ACTI_UNIT3_ISO TYPE STRING,
CONF_ACTIVITY3 TYPE STRING,
NO_REMN_ACTI3 TYPE STRING,
CONF_ACTI_UNIT4 TYPE STRING,
CONF_ACTI_UNIT4_ISO TYPE STRING,
CONF_ACTIVITY4 TYPE STRING,
NO_REMN_ACTI4 TYPE STRING,
CONF_ACTI_UNIT5 TYPE STRING,
CONF_ACTI_UNIT5_ISO TYPE STRING,
CONF_ACTIVITY5 TYPE STRING,
NO_REMN_ACTI5 TYPE STRING,
CONF_ACTI_UNIT6 TYPE STRING,
CONF_ACTI_UNIT6_ISO TYPE STRING,
CONF_ACTIVITY6 TYPE STRING,
NO_REMN_ACTI6 TYPE STRING,
CONF_BUS_PROC_UNIT1 TYPE STRING,
CONF_BUS_PROC_UNIT1_ISO TYPE STRING,
CONF_BUSS_PROC1 TYPE STRING,
NO_REMN_BUS_PROC1 TYPE STRING,
PERS_NO TYPE STRING,
TIMEID_NO TYPE STRING,
WAGETYPE TYPE STRING,
EX_CREATED_BY TYPE STRING,
EX_CREATED_DATE TYPE STRING,
EX_CREATED_TIME TYPE STRING,
TARGET_ACTI1 TYPE STRING,
TARGET_ACTI2 TYPE STRING,
TARGET_ACTI3 TYPE STRING,
TARGET_ACTI4 TYPE STRING,
TARGET_ACTI5 TYPE STRING,
TARGET_ACTI6 TYPE STRING,
TARGET_BUS_PROC1 TYPE STRING,
EX_IDENT TYPE STRING,END OF T_EKKO_STR. DATA: WA_E1BP_PP_TIMEEVENT_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_E1BP_PP_TIMEEVENT_STR-CONF_NO sy-vline
WA_E1BP_PP_TIMEEVENT_STR-ORDERID sy-vline
WA_E1BP_PP_TIMEEVENT_STR-SEQUENCE sy-vline
WA_E1BP_PP_TIMEEVENT_STR-OPERATION sy-vline
WA_E1BP_PP_TIMEEVENT_STR-SUB_OPER sy-vline
WA_E1BP_PP_TIMEEVENT_STR-CAPA_CATEGORY sy-vline
WA_E1BP_PP_TIMEEVENT_STR-SPLIT sy-vline
WA_E1BP_PP_TIMEEVENT_STR-RECORDTYPE sy-vline
WA_E1BP_PP_TIMEEVENT_STR-LOGDATE sy-vline
WA_E1BP_PP_TIMEEVENT_STR-LOGTIME sy-vline
WA_E1BP_PP_TIMEEVENT_STR-FIN_CONF sy-vline
WA_E1BP_PP_TIMEEVENT_STR-CLEAR_RES sy-vline
WA_E1BP_PP_TIMEEVENT_STR-POSTG_DATE sy-vline
WA_E1BP_PP_TIMEEVENT_STR-DEV_REASON sy-vline
WA_E1BP_PP_TIMEEVENT_STR-CONF_TEXT sy-vline
WA_E1BP_PP_TIMEEVENT_STR-CONF_QUAN_UNIT sy-vline
WA_E1BP_PP_TIMEEVENT_STR-CONF_QUAN_UNIT_ISO sy-vline
WA_E1BP_PP_TIMEEVENT_STR-YIELD sy-vline
WA_E1BP_PP_TIMEEVENT_STR-SCRAP sy-vline
WA_E1BP_PP_TIMEEVENT_STR-REWORK sy-vline
WA_E1BP_PP_TIMEEVENT_STR-PLANT sy-vline
WA_E1BP_PP_TIMEEVENT_STR-WORK_CNTR sy-vline
WA_E1BP_PP_TIMEEVENT_STR-CONF_ACTI_UNIT1 sy-vline
WA_E1BP_PP_TIMEEVENT_STR-CONF_ACTI_UNIT1_ISO sy-vline
WA_E1BP_PP_TIMEEVENT_STR-CONF_ACTIVITY1 sy-vline
WA_E1BP_PP_TIMEEVENT_STR-NO_REMN_ACTI1 sy-vline
WA_E1BP_PP_TIMEEVENT_STR-CONF_ACTI_UNIT2 sy-vline
WA_E1BP_PP_TIMEEVENT_STR-CONF_ACTI_UNIT2_ISO sy-vline
WA_E1BP_PP_TIMEEVENT_STR-CONF_ACTIVITY2 sy-vline
WA_E1BP_PP_TIMEEVENT_STR-NO_REMN_ACTI2 sy-vline
WA_E1BP_PP_TIMEEVENT_STR-CONF_ACTI_UNIT3 sy-vline
WA_E1BP_PP_TIMEEVENT_STR-CONF_ACTI_UNIT3_ISO sy-vline
WA_E1BP_PP_TIMEEVENT_STR-CONF_ACTIVITY3 sy-vline
WA_E1BP_PP_TIMEEVENT_STR-NO_REMN_ACTI3 sy-vline
WA_E1BP_PP_TIMEEVENT_STR-CONF_ACTI_UNIT4 sy-vline
WA_E1BP_PP_TIMEEVENT_STR-CONF_ACTI_UNIT4_ISO sy-vline
WA_E1BP_PP_TIMEEVENT_STR-CONF_ACTIVITY4 sy-vline
WA_E1BP_PP_TIMEEVENT_STR-NO_REMN_ACTI4 sy-vline
WA_E1BP_PP_TIMEEVENT_STR-CONF_ACTI_UNIT5 sy-vline
WA_E1BP_PP_TIMEEVENT_STR-CONF_ACTI_UNIT5_ISO sy-vline
WA_E1BP_PP_TIMEEVENT_STR-CONF_ACTIVITY5 sy-vline
WA_E1BP_PP_TIMEEVENT_STR-NO_REMN_ACTI5 sy-vline
WA_E1BP_PP_TIMEEVENT_STR-CONF_ACTI_UNIT6 sy-vline
WA_E1BP_PP_TIMEEVENT_STR-CONF_ACTI_UNIT6_ISO sy-vline
WA_E1BP_PP_TIMEEVENT_STR-CONF_ACTIVITY6 sy-vline
WA_E1BP_PP_TIMEEVENT_STR-NO_REMN_ACTI6 sy-vline
WA_E1BP_PP_TIMEEVENT_STR-CONF_BUS_PROC_UNIT1 sy-vline
WA_E1BP_PP_TIMEEVENT_STR-CONF_BUS_PROC_UNIT1_ISO sy-vline
WA_E1BP_PP_TIMEEVENT_STR-CONF_BUSS_PROC1 sy-vline
WA_E1BP_PP_TIMEEVENT_STR-NO_REMN_BUS_PROC1 sy-vline
WA_E1BP_PP_TIMEEVENT_STR-PERS_NO sy-vline
WA_E1BP_PP_TIMEEVENT_STR-TIMEID_NO sy-vline
WA_E1BP_PP_TIMEEVENT_STR-WAGETYPE sy-vline
WA_E1BP_PP_TIMEEVENT_STR-EX_CREATED_BY sy-vline
WA_E1BP_PP_TIMEEVENT_STR-EX_CREATED_DATE sy-vline
WA_E1BP_PP_TIMEEVENT_STR-EX_CREATED_TIME sy-vline
WA_E1BP_PP_TIMEEVENT_STR-TARGET_ACTI1 sy-vline
WA_E1BP_PP_TIMEEVENT_STR-TARGET_ACTI2 sy-vline
WA_E1BP_PP_TIMEEVENT_STR-TARGET_ACTI3 sy-vline
WA_E1BP_PP_TIMEEVENT_STR-TARGET_ACTI4 sy-vline
WA_E1BP_PP_TIMEEVENT_STR-TARGET_ACTI5 sy-vline
WA_E1BP_PP_TIMEEVENT_STR-TARGET_ACTI6 sy-vline
WA_E1BP_PP_TIMEEVENT_STR-TARGET_BUS_PROC1 sy-vline
WA_E1BP_PP_TIMEEVENT_STR-EX_IDENT sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.