ABAP Select data from SAP table E1BP_EHHSSS_INC_EHSM_BINFA into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP E1BP_EHHSSS_INC_EHSM_BINFA table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to E1BP_EHHSSS_INC_EHSM_BINFA. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the E1BP_EHHSSS_INC_EHSM_BINFA table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_E1BP_EHHSSS_INC_EHSM_BINFA TYPE STANDARD TABLE OF E1BP_EHHSSS_INC_EHSM_BINFA,
      WA_E1BP_EHHSSS_INC_EHSM_BINFA TYPE E1BP_EHHSSS_INC_EHSM_BINFA,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <E1BP_EHHSSS_INC_EHSM_BINFA> TYPE E1BP_EHHSSS_INC_EHSM_BINFA.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_E1BP_EHHSSS_INC_EHSM_BINFA.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM E1BP_EHHSSS_INC_EHSM_BINFA
  INTO TABLE IT_E1BP_EHHSSS_INC_EHSM_BINFA.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM E1BP_EHHSSS_INC_EHSM_BINFA
*  INTO TABLE @DATA(IT_E1BP_EHHSSS_INC_EHSM_BINFA2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_E1BP_EHHSSS_INC_EHSM_BINFA INDEX 1 INTO DATA(WA_E1BP_EHHSSS_INC_EHSM_BINFA2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_E1BP_EHHSSS_INC_EHSM_BINFA ASSIGNING <E1BP_EHHSSS_INC_EHSM_BINFA>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<E1BP_EHHSSS_INC_EHSM_BINFA>-SOURCE_NODE_NAME = 1.
<E1BP_EHHSSS_INC_EHSM_BINFA>-SOURCE_KEY = 1.
<E1BP_EHHSSS_INC_EHSM_BINFA>-SOURCE_PARENT_KEY = 1.
<E1BP_EHHSSS_INC_EHSM_BINFA>-TITLE = 1.
<E1BP_EHHSSS_INC_EHSM_BINFA>-ORG_ID = 1.
ENDLOOP.

LOOP AT IT_E1BP_EHHSSS_INC_EHSM_BINFA INTO WA_E1BP_EHHSSS_INC_EHSM_BINFA.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_E1BP_EHHSSS_INC_EHSM_BINFA-PLANT_ID, sy-vline,
WA_E1BP_EHHSSS_INC_EHSM_BINFA-LOC_ROOT_KEY_REF, sy-vline,
WA_E1BP_EHHSSS_INC_EHSM_BINFA-LOC_TYPE, sy-vline,
WA_E1BP_EHHSSS_INC_EHSM_BINFA-START_TIMESTAMP, sy-vline,
WA_E1BP_EHHSSS_INC_EHSM_BINFA-START_TIME_ZONE, sy-vline,
WA_E1BP_EHHSSS_INC_EHSM_BINFA-END_TIMESTAMP, sy-vline.
ENDLOOP. *Add any further fields from structure WA_E1BP_EHHSSS_INC_EHSM_BINFA you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_E1BP_EHHSSS_INC_EHSM_BINFA TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_E1BP_EHHSSS_INC_EHSM_BINFA INTO WA_E1BP_EHHSSS_INC_EHSM_BINFA. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_E1BP_EHHSSS_INC_EHSM_BINFA_STR,
SOURCE_NODE_NAME TYPE STRING,
SOURCE_KEY TYPE STRING,
SOURCE_PARENT_KEY TYPE STRING,
TITLE TYPE STRING,
ORG_ID TYPE STRING,
PLANT_ID TYPE STRING,
LOC_ROOT_KEY_REF TYPE STRING,
LOC_TYPE TYPE STRING,
START_TIMESTAMP TYPE STRING,
START_TIME_ZONE TYPE STRING,
END_TIMESTAMP TYPE STRING,
END_TIME_ZONE TYPE STRING,
TIME_NOT_DET_IND TYPE STRING,
REP_TIMESTAMP TYPE STRING,
REP_TIME_ZONE TYPE STRING,
CONFIDENTIAL_TS TYPE STRING,
LOSS_OF_PROD_TS TYPE STRING,
EMERG_RESP_TS TYPE STRING,
LATIT_MEAS TYPE STRING,
LONG_MEAS TYPE STRING,
ALTIT_MEAS TYPE STRING,
ALTIT_UNIT TYPE STRING,
STREET_HOUSE_NUM TYPE STRING,
POSTAL_CODE TYPE STRING,
CITY TYPE STRING,
COUNTRY TYPE STRING,
REGION TYPE STRING,
SHIFT_GROUP TYPE STRING,
SHIFT_PLAN_ID TYPE STRING,
REP_ANONYM_IND TYPE STRING,
DIS_WA_MEAS TYPE STRING,
DIS_WA_UNIT TYPE STRING,
PRECIP_MEAS TYPE STRING,
PRECIP_UNIT TYPE STRING,
WI_DIREC TYPE STRING,
WI_FO_MEAS TYPE STRING,
WI_FO_UNIT TYPE STRING,
TXC_WEA_COMM_KEY TYPE STRING,
TXC_DESC_KEY TYPE STRING,
TXC_LOC_DESC_KEY TYPE STRING,
TXC_IMA_DESC_KEY TYPE STRING,
TEST_RUN TYPE STRING,END OF T_EKKO_STR. DATA: WA_E1BP_EHHSSS_INC_EHSM_BINFA_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_E1BP_EHHSSS_INC_EHSM_BINFA_STR-SOURCE_NODE_NAME sy-vline
WA_E1BP_EHHSSS_INC_EHSM_BINFA_STR-SOURCE_KEY sy-vline
WA_E1BP_EHHSSS_INC_EHSM_BINFA_STR-SOURCE_PARENT_KEY sy-vline
WA_E1BP_EHHSSS_INC_EHSM_BINFA_STR-TITLE sy-vline
WA_E1BP_EHHSSS_INC_EHSM_BINFA_STR-ORG_ID sy-vline
WA_E1BP_EHHSSS_INC_EHSM_BINFA_STR-PLANT_ID sy-vline
WA_E1BP_EHHSSS_INC_EHSM_BINFA_STR-LOC_ROOT_KEY_REF sy-vline
WA_E1BP_EHHSSS_INC_EHSM_BINFA_STR-LOC_TYPE sy-vline
WA_E1BP_EHHSSS_INC_EHSM_BINFA_STR-START_TIMESTAMP sy-vline
WA_E1BP_EHHSSS_INC_EHSM_BINFA_STR-START_TIME_ZONE sy-vline
WA_E1BP_EHHSSS_INC_EHSM_BINFA_STR-END_TIMESTAMP sy-vline
WA_E1BP_EHHSSS_INC_EHSM_BINFA_STR-END_TIME_ZONE sy-vline
WA_E1BP_EHHSSS_INC_EHSM_BINFA_STR-TIME_NOT_DET_IND sy-vline
WA_E1BP_EHHSSS_INC_EHSM_BINFA_STR-REP_TIMESTAMP sy-vline
WA_E1BP_EHHSSS_INC_EHSM_BINFA_STR-REP_TIME_ZONE sy-vline
WA_E1BP_EHHSSS_INC_EHSM_BINFA_STR-CONFIDENTIAL_TS sy-vline
WA_E1BP_EHHSSS_INC_EHSM_BINFA_STR-LOSS_OF_PROD_TS sy-vline
WA_E1BP_EHHSSS_INC_EHSM_BINFA_STR-EMERG_RESP_TS sy-vline
WA_E1BP_EHHSSS_INC_EHSM_BINFA_STR-LATIT_MEAS sy-vline
WA_E1BP_EHHSSS_INC_EHSM_BINFA_STR-LONG_MEAS sy-vline
WA_E1BP_EHHSSS_INC_EHSM_BINFA_STR-ALTIT_MEAS sy-vline
WA_E1BP_EHHSSS_INC_EHSM_BINFA_STR-ALTIT_UNIT sy-vline
WA_E1BP_EHHSSS_INC_EHSM_BINFA_STR-STREET_HOUSE_NUM sy-vline
WA_E1BP_EHHSSS_INC_EHSM_BINFA_STR-POSTAL_CODE sy-vline
WA_E1BP_EHHSSS_INC_EHSM_BINFA_STR-CITY sy-vline
WA_E1BP_EHHSSS_INC_EHSM_BINFA_STR-COUNTRY sy-vline
WA_E1BP_EHHSSS_INC_EHSM_BINFA_STR-REGION sy-vline
WA_E1BP_EHHSSS_INC_EHSM_BINFA_STR-SHIFT_GROUP sy-vline
WA_E1BP_EHHSSS_INC_EHSM_BINFA_STR-SHIFT_PLAN_ID sy-vline
WA_E1BP_EHHSSS_INC_EHSM_BINFA_STR-REP_ANONYM_IND sy-vline
WA_E1BP_EHHSSS_INC_EHSM_BINFA_STR-DIS_WA_MEAS sy-vline
WA_E1BP_EHHSSS_INC_EHSM_BINFA_STR-DIS_WA_UNIT sy-vline
WA_E1BP_EHHSSS_INC_EHSM_BINFA_STR-PRECIP_MEAS sy-vline
WA_E1BP_EHHSSS_INC_EHSM_BINFA_STR-PRECIP_UNIT sy-vline
WA_E1BP_EHHSSS_INC_EHSM_BINFA_STR-WI_DIREC sy-vline
WA_E1BP_EHHSSS_INC_EHSM_BINFA_STR-WI_FO_MEAS sy-vline
WA_E1BP_EHHSSS_INC_EHSM_BINFA_STR-WI_FO_UNIT sy-vline
WA_E1BP_EHHSSS_INC_EHSM_BINFA_STR-TXC_WEA_COMM_KEY sy-vline
WA_E1BP_EHHSSS_INC_EHSM_BINFA_STR-TXC_DESC_KEY sy-vline
WA_E1BP_EHHSSS_INC_EHSM_BINFA_STR-TXC_LOC_DESC_KEY sy-vline
WA_E1BP_EHHSSS_INC_EHSM_BINFA_STR-TXC_IMA_DESC_KEY sy-vline
WA_E1BP_EHHSSS_INC_EHSM_BINFA_STR-TEST_RUN sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.