ABAP Select data from SAP table E1BP1198_SR_RCP into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP E1BP1198_SR_RCP table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to E1BP1198_SR_RCP. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the E1BP1198_SR_RCP table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_E1BP1198_SR_RCP TYPE STANDARD TABLE OF E1BP1198_SR_RCP,
      WA_E1BP1198_SR_RCP TYPE E1BP1198_SR_RCP,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <E1BP1198_SR_RCP> TYPE E1BP1198_SR_RCP.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_E1BP1198_SR_RCP.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM E1BP1198_SR_RCP
  INTO TABLE IT_E1BP1198_SR_RCP.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM E1BP1198_SR_RCP
*  INTO TABLE @DATA(IT_E1BP1198_SR_RCP2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_E1BP1198_SR_RCP INDEX 1 INTO DATA(WA_E1BP1198_SR_RCP2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_E1BP1198_SR_RCP ASSIGNING <E1BP1198_SR_RCP>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<E1BP1198_SR_RCP>-MANDT = 1.
<E1BP1198_SR_RCP>-NODE_ID = 1.
<E1BP1198_SR_RCP>-CHANGE_NO = 1.
<E1BP1198_SR_RCP>-GUID_MAST = 1.
<E1BP1198_SR_RCP>-GUID_ROOT = 1.
ENDLOOP.

LOOP AT IT_E1BP1198_SR_RCP INTO WA_E1BP1198_SR_RCP.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_E1BP1198_SR_RCP-CHANGE_NO_ROOT, sy-vline,
WA_E1BP1198_SR_RCP-NODE_NAME, sy-vline,
WA_E1BP1198_SR_RCP-NODE_TYPE, sy-vline,
WA_E1BP1198_SR_RCP-VARIANT_ID, sy-vline,
WA_E1BP1198_SR_RCP-VARIANT_TYPE, sy-vline,
WA_E1BP1198_SR_RCP-NODE_CNT, sy-vline.
ENDLOOP. *Add any further fields from structure WA_E1BP1198_SR_RCP you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_E1BP1198_SR_RCP TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_E1BP1198_SR_RCP INTO WA_E1BP1198_SR_RCP. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_E1BP1198_SR_RCP_STR,
MANDT TYPE STRING,
NODE_ID TYPE STRING,
CHANGE_NO TYPE STRING,
GUID_MAST TYPE STRING,
GUID_ROOT TYPE STRING,
CHANGE_NO_ROOT TYPE STRING,
NODE_NAME TYPE STRING,
NODE_TYPE TYPE STRING,
VARIANT_ID TYPE STRING,
VARIANT_TYPE TYPE STRING,
NODE_CNT TYPE STRING,
STATUS TYPE STRING,
ISTATUS_OLD TYPE STRING,
OBJECT_NO TYPE STRING,
VALFROM TYPE STRING,
VALTO TYPE STRING,
LOT_SIZE_MIN TYPE STRING,
LOT_SIZE_MAX TYPE STRING,
QUANTITY_UNIT TYPE STRING,
QUANTITY_UNIT_ISO TYPE STRING,
OTYPE TYPE STRING,
REALO TYPE STRING,
RCP_TIMSTMP TYPE STRING,
PLANT TYPE STRING,
MATERIAL TYPE STRING,
VERSION TYPE STRING,
REFQUANT TYPE STRING,
PROJECT TYPE STRING,
DEV_TIME TYPE STRING,
PROD_TIME TYPE STRING,
CONF_FLAG TYPE STRING,
LANGU TYPE STRING,
LANGU_ISO TYPE STRING,
PVTXCNT TYPE STRING,
RESCREATXCNT TYPE STRING,
COPY_FROM TYPE STRING,
TIMEUNIT TYPE STRING,
TIMEUNIT_ISO TYPE STRING,
AUTH_GRP TYPE STRING,
RECORD_NO TYPE STRING,
SUBCATEGRY TYPE STRING,
SUBSTANCE TYPE STRING,
GUID_PRE TYPE STRING,
GUID_ORI TYPE STRING,
NAM TYPE STRING,
VRS_TYPE TYPE STRING,
CREATED_DATE TYPE STRING,
CREATED_BY TYPE STRING,
CHANGED_DATE TYPE STRING,
CHANGED_BY TYPE STRING,
LOG_SYSTEM TYPE STRING,
RCP_CREADAT TYPE STRING,
RCP_CREABY TYPE STRING,
RCP_CHNGDAT TYPE STRING,
RCP_CHNGBY TYPE STRING,
RCP_LOGSYS TYPE STRING,
LINEMODE TYPE STRING,
MATERIAL_EXTERNAL TYPE STRING,
MATERIAL_GUID TYPE STRING,
MATERIAL_VERSION TYPE STRING,
MATERIAL_LONG TYPE STRING,END OF T_EKKO_STR. DATA: WA_E1BP1198_SR_RCP_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_E1BP1198_SR_RCP_STR-MANDT sy-vline
WA_E1BP1198_SR_RCP_STR-NODE_ID sy-vline
WA_E1BP1198_SR_RCP_STR-CHANGE_NO sy-vline
WA_E1BP1198_SR_RCP_STR-GUID_MAST sy-vline
WA_E1BP1198_SR_RCP_STR-GUID_ROOT sy-vline
WA_E1BP1198_SR_RCP_STR-CHANGE_NO_ROOT sy-vline
WA_E1BP1198_SR_RCP_STR-NODE_NAME sy-vline
WA_E1BP1198_SR_RCP_STR-NODE_TYPE sy-vline
WA_E1BP1198_SR_RCP_STR-VARIANT_ID sy-vline
WA_E1BP1198_SR_RCP_STR-VARIANT_TYPE sy-vline
WA_E1BP1198_SR_RCP_STR-NODE_CNT sy-vline
WA_E1BP1198_SR_RCP_STR-STATUS sy-vline
WA_E1BP1198_SR_RCP_STR-ISTATUS_OLD sy-vline
WA_E1BP1198_SR_RCP_STR-OBJECT_NO sy-vline
WA_E1BP1198_SR_RCP_STR-VALFROM sy-vline
WA_E1BP1198_SR_RCP_STR-VALTO sy-vline
WA_E1BP1198_SR_RCP_STR-LOT_SIZE_MIN sy-vline
WA_E1BP1198_SR_RCP_STR-LOT_SIZE_MAX sy-vline
WA_E1BP1198_SR_RCP_STR-QUANTITY_UNIT sy-vline
WA_E1BP1198_SR_RCP_STR-QUANTITY_UNIT_ISO sy-vline
WA_E1BP1198_SR_RCP_STR-OTYPE sy-vline
WA_E1BP1198_SR_RCP_STR-REALO sy-vline
WA_E1BP1198_SR_RCP_STR-RCP_TIMSTMP sy-vline
WA_E1BP1198_SR_RCP_STR-PLANT sy-vline
WA_E1BP1198_SR_RCP_STR-MATERIAL sy-vline
WA_E1BP1198_SR_RCP_STR-VERSION sy-vline
WA_E1BP1198_SR_RCP_STR-REFQUANT sy-vline
WA_E1BP1198_SR_RCP_STR-PROJECT sy-vline
WA_E1BP1198_SR_RCP_STR-DEV_TIME sy-vline
WA_E1BP1198_SR_RCP_STR-PROD_TIME sy-vline
WA_E1BP1198_SR_RCP_STR-CONF_FLAG sy-vline
WA_E1BP1198_SR_RCP_STR-LANGU sy-vline
WA_E1BP1198_SR_RCP_STR-LANGU_ISO sy-vline
WA_E1BP1198_SR_RCP_STR-PVTXCNT sy-vline
WA_E1BP1198_SR_RCP_STR-RESCREATXCNT sy-vline
WA_E1BP1198_SR_RCP_STR-COPY_FROM sy-vline
WA_E1BP1198_SR_RCP_STR-TIMEUNIT sy-vline
WA_E1BP1198_SR_RCP_STR-TIMEUNIT_ISO sy-vline
WA_E1BP1198_SR_RCP_STR-AUTH_GRP sy-vline
WA_E1BP1198_SR_RCP_STR-RECORD_NO sy-vline
WA_E1BP1198_SR_RCP_STR-SUBCATEGRY sy-vline
WA_E1BP1198_SR_RCP_STR-SUBSTANCE sy-vline
WA_E1BP1198_SR_RCP_STR-GUID_PRE sy-vline
WA_E1BP1198_SR_RCP_STR-GUID_ORI sy-vline
WA_E1BP1198_SR_RCP_STR-NAM sy-vline
WA_E1BP1198_SR_RCP_STR-VRS_TYPE sy-vline
WA_E1BP1198_SR_RCP_STR-CREATED_DATE sy-vline
WA_E1BP1198_SR_RCP_STR-CREATED_BY sy-vline
WA_E1BP1198_SR_RCP_STR-CHANGED_DATE sy-vline
WA_E1BP1198_SR_RCP_STR-CHANGED_BY sy-vline
WA_E1BP1198_SR_RCP_STR-LOG_SYSTEM sy-vline
WA_E1BP1198_SR_RCP_STR-RCP_CREADAT sy-vline
WA_E1BP1198_SR_RCP_STR-RCP_CREABY sy-vline
WA_E1BP1198_SR_RCP_STR-RCP_CHNGDAT sy-vline
WA_E1BP1198_SR_RCP_STR-RCP_CHNGBY sy-vline
WA_E1BP1198_SR_RCP_STR-RCP_LOGSYS sy-vline
WA_E1BP1198_SR_RCP_STR-LINEMODE sy-vline
WA_E1BP1198_SR_RCP_STR-MATERIAL_EXTERNAL sy-vline
WA_E1BP1198_SR_RCP_STR-MATERIAL_GUID sy-vline
WA_E1BP1198_SR_RCP_STR-MATERIAL_VERSION sy-vline
WA_E1BP1198_SR_RCP_STR-MATERIAL_LONG sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.