ABAP Select data from SAP table E1BP10001LOCPRDSTGETYPEO into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP E1BP10001LOCPRDSTGETYPEO table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to E1BP10001LOCPRDSTGETYPEO. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the E1BP10001LOCPRDSTGETYPEO table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_E1BP10001LOCPRDSTGETYPEO TYPE STANDARD TABLE OF E1BP10001LOCPRDSTGETYPEO,
      WA_E1BP10001LOCPRDSTGETYPEO TYPE E1BP10001LOCPRDSTGETYPEO,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <E1BP10001LOCPRDSTGETYPEO> TYPE E1BP10001LOCPRDSTGETYPEO.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_E1BP10001LOCPRDSTGETYPEO.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM E1BP10001LOCPRDSTGETYPEO
  INTO TABLE IT_E1BP10001LOCPRDSTGETYPEO.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM E1BP10001LOCPRDSTGETYPEO
*  INTO TABLE @DATA(IT_E1BP10001LOCPRDSTGETYPEO2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_E1BP10001LOCPRDSTGETYPEO INDEX 1 INTO DATA(WA_E1BP10001LOCPRDSTGETYPEO2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_E1BP10001LOCPRDSTGETYPEO ASSIGNING <E1BP10001LOCPRDSTGETYPEO>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<E1BP10001LOCPRDSTGETYPEO>-PRODUCT_ID = 1.
<E1BP10001LOCPRDSTGETYPEO>-PRODUCT = 1.
<E1BP10001LOCPRDSTGETYPEO>-PRODUCT_BSG = 1.
<E1BP10001LOCPRDSTGETYPEO>-PRODUCT_INT = 1.
<E1BP10001LOCPRDSTGETYPEO>-SC_UNIT = 1.
ENDLOOP.

LOOP AT IT_E1BP10001LOCPRDSTGETYPEO INTO WA_E1BP10001LOCPRDSTGETYPEO.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_E1BP10001LOCPRDSTGETYPEO-SC_UNIT_TYPE, sy-vline,
WA_E1BP10001LOCPRDSTGETYPEO-ENTITLED, sy-vline,
WA_E1BP10001LOCPRDSTGETYPEO-ENTITLED_TYPE, sy-vline,
WA_E1BP10001LOCPRDSTGETYPEO-STGE_TYPE, sy-vline,
WA_E1BP10001LOCPRDSTGETYPEO-STGESECTOR, sy-vline,
WA_E1BP10001LOCPRDSTGETYPEO-STGESECTOR_FIXED_FLAG, sy-vline.
ENDLOOP. *Add any further fields from structure WA_E1BP10001LOCPRDSTGETYPEO you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_E1BP10001LOCPRDSTGETYPEO TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_E1BP10001LOCPRDSTGETYPEO INTO WA_E1BP10001LOCPRDSTGETYPEO. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_E1BP10001LOCPRDSTGETYPEO_STR,
PRODUCT_ID TYPE STRING,
PRODUCT TYPE STRING,
PRODUCT_BSG TYPE STRING,
PRODUCT_INT TYPE STRING,
SC_UNIT TYPE STRING,
SC_UNIT_TYPE TYPE STRING,
ENTITLED TYPE STRING,
ENTITLED_TYPE TYPE STRING,
STGE_TYPE TYPE STRING,
STGESECTOR TYPE STRING,
STGESECTOR_FIXED_FLAG TYPE STRING,
PLANNED_STGESECTOR TYPE STRING,
STGEBIN_TYPE TYPE STRING,
STGEBIN_TYPE_FIXED_FLAG TYPE STRING,
PLANNED_STGEBIN_TYPE TYPE STRING,
MAX_FIXED_STGEBIN TYPE STRING,
MAX_FIXED_STGEBIN_FIXED_FLAG TYPE STRING,
MAX_QTY TYPE STRING,
MAX_QTY_PLND TYPE STRING,
MAX_QTY_DSPL_UOM TYPE STRING,
MAX_QTY_DSPL_UOM_ISO TYPE STRING,
MIN_QTY TYPE STRING,
MIN_QTY_PLND TYPE STRING,
MIN_QTY_DSPL_UOM TYPE STRING,
MIN_QTY_DSPL_UOM_ISO TYPE STRING,
MIN_REP_QTY TYPE STRING,
MIN_REP_QTY_PLND TYPE STRING,
MIN_REP_QTY_DSPL_UOM TYPE STRING,
MIN_REP_QTY_DSPL_UOM_ISO TYPE STRING,
MIN_MAX_QTY_FIXED_FLAG TYPE STRING,
MIN_MAX_QTY_PERCENTAGE TYPE STRING,
ADD_TO_EXIST_STOCK_THRESHOLD TYPE STRING,
NO_REPLENISHMENT_FLAG TYPE STRING,
EMTPY_STGEBIN_SORT_RULE TYPE STRING,
QUANCLA TYPE STRING,
PUTAWAY_SEQUENCE TYPE STRING,
PUTAWAY_SEQUENCE_PLND TYPE STRING,
PUTAWAY_SKIP_FLAG TYPE STRING,
PUTAWAY_SKIP_FLAG_PLND TYPE STRING,
PRDTYPE TYPE STRING,
MAX_STGEBIN_PLANNED TYPE STRING,
PUTAWAY_SPLIT_FLAG TYPE STRING,
PUTAWAY_SEQUENCE_FIXED_FLAG TYPE STRING,
PUTAWAY_SKIP_FIXED_FLAG TYPE STRING,END OF T_EKKO_STR. DATA: WA_E1BP10001LOCPRDSTGETYPEO_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_E1BP10001LOCPRDSTGETYPEO_STR-PRODUCT_ID sy-vline
WA_E1BP10001LOCPRDSTGETYPEO_STR-PRODUCT sy-vline
WA_E1BP10001LOCPRDSTGETYPEO_STR-PRODUCT_BSG sy-vline
WA_E1BP10001LOCPRDSTGETYPEO_STR-PRODUCT_INT sy-vline
WA_E1BP10001LOCPRDSTGETYPEO_STR-SC_UNIT sy-vline
WA_E1BP10001LOCPRDSTGETYPEO_STR-SC_UNIT_TYPE sy-vline
WA_E1BP10001LOCPRDSTGETYPEO_STR-ENTITLED sy-vline
WA_E1BP10001LOCPRDSTGETYPEO_STR-ENTITLED_TYPE sy-vline
WA_E1BP10001LOCPRDSTGETYPEO_STR-STGE_TYPE sy-vline
WA_E1BP10001LOCPRDSTGETYPEO_STR-STGESECTOR sy-vline
WA_E1BP10001LOCPRDSTGETYPEO_STR-STGESECTOR_FIXED_FLAG sy-vline
WA_E1BP10001LOCPRDSTGETYPEO_STR-PLANNED_STGESECTOR sy-vline
WA_E1BP10001LOCPRDSTGETYPEO_STR-STGEBIN_TYPE sy-vline
WA_E1BP10001LOCPRDSTGETYPEO_STR-STGEBIN_TYPE_FIXED_FLAG sy-vline
WA_E1BP10001LOCPRDSTGETYPEO_STR-PLANNED_STGEBIN_TYPE sy-vline
WA_E1BP10001LOCPRDSTGETYPEO_STR-MAX_FIXED_STGEBIN sy-vline
WA_E1BP10001LOCPRDSTGETYPEO_STR-MAX_FIXED_STGEBIN_FIXED_FLAG sy-vline
WA_E1BP10001LOCPRDSTGETYPEO_STR-MAX_QTY sy-vline
WA_E1BP10001LOCPRDSTGETYPEO_STR-MAX_QTY_PLND sy-vline
WA_E1BP10001LOCPRDSTGETYPEO_STR-MAX_QTY_DSPL_UOM sy-vline
WA_E1BP10001LOCPRDSTGETYPEO_STR-MAX_QTY_DSPL_UOM_ISO sy-vline
WA_E1BP10001LOCPRDSTGETYPEO_STR-MIN_QTY sy-vline
WA_E1BP10001LOCPRDSTGETYPEO_STR-MIN_QTY_PLND sy-vline
WA_E1BP10001LOCPRDSTGETYPEO_STR-MIN_QTY_DSPL_UOM sy-vline
WA_E1BP10001LOCPRDSTGETYPEO_STR-MIN_QTY_DSPL_UOM_ISO sy-vline
WA_E1BP10001LOCPRDSTGETYPEO_STR-MIN_REP_QTY sy-vline
WA_E1BP10001LOCPRDSTGETYPEO_STR-MIN_REP_QTY_PLND sy-vline
WA_E1BP10001LOCPRDSTGETYPEO_STR-MIN_REP_QTY_DSPL_UOM sy-vline
WA_E1BP10001LOCPRDSTGETYPEO_STR-MIN_REP_QTY_DSPL_UOM_ISO sy-vline
WA_E1BP10001LOCPRDSTGETYPEO_STR-MIN_MAX_QTY_FIXED_FLAG sy-vline
WA_E1BP10001LOCPRDSTGETYPEO_STR-MIN_MAX_QTY_PERCENTAGE sy-vline
WA_E1BP10001LOCPRDSTGETYPEO_STR-ADD_TO_EXIST_STOCK_THRESHOLD sy-vline
WA_E1BP10001LOCPRDSTGETYPEO_STR-NO_REPLENISHMENT_FLAG sy-vline
WA_E1BP10001LOCPRDSTGETYPEO_STR-EMTPY_STGEBIN_SORT_RULE sy-vline
WA_E1BP10001LOCPRDSTGETYPEO_STR-QUANCLA sy-vline
WA_E1BP10001LOCPRDSTGETYPEO_STR-PUTAWAY_SEQUENCE sy-vline
WA_E1BP10001LOCPRDSTGETYPEO_STR-PUTAWAY_SEQUENCE_PLND sy-vline
WA_E1BP10001LOCPRDSTGETYPEO_STR-PUTAWAY_SKIP_FLAG sy-vline
WA_E1BP10001LOCPRDSTGETYPEO_STR-PUTAWAY_SKIP_FLAG_PLND sy-vline
WA_E1BP10001LOCPRDSTGETYPEO_STR-PRDTYPE sy-vline
WA_E1BP10001LOCPRDSTGETYPEO_STR-MAX_STGEBIN_PLANNED sy-vline
WA_E1BP10001LOCPRDSTGETYPEO_STR-PUTAWAY_SPLIT_FLAG sy-vline
WA_E1BP10001LOCPRDSTGETYPEO_STR-PUTAWAY_SEQUENCE_FIXED_FLAG sy-vline
WA_E1BP10001LOCPRDSTGETYPEO_STR-PUTAWAY_SKIP_FIXED_FLAG sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.