ABAP Select data from SAP table E1685A into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP E1685A table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to E1685A. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the E1685A table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_E1685A TYPE STANDARD TABLE OF E1685A,
      WA_E1685A TYPE E1685A,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <E1685A> TYPE E1685A.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_E1685A.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM E1685A
  INTO TABLE IT_E1685A.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM E1685A
*  INTO TABLE @DATA(IT_E1685A2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_E1685A INDEX 1 INTO DATA(WA_E1685A2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_E1685A ASSIGNING <E1685A>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<E1685A>-KRECH = 1.
<E1685A>-KZBZG = 1.
<E1685A>-KNTYP = 1.
<E1685A>-KONAU = 1.
<E1685A>-KMANU = 1.
ENDLOOP.

LOOP AT IT_E1685A INTO WA_E1685A.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_E1685A-GRZGF, sy-vline,
WA_E1685A-GRLNR, sy-vline,
WA_E1685A-GRMEN, sy-vline,
WA_E1685A-GANZZ, sy-vline,
WA_E1685A-KGRPE, sy-vline,
WA_E1685A-KRELI, sy-vline.
ENDLOOP. *Add any further fields from structure WA_E1685A you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_E1685A TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_E1685A INTO WA_E1685A. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_E1685A_STR,
KRECH TYPE STRING,
KZBZG TYPE STRING,
KNTYP TYPE STRING,
KONAU TYPE STRING,
KMANU TYPE STRING,
GRZGF TYPE STRING,
GRLNR TYPE STRING,
GRMEN TYPE STRING,
GANZZ TYPE STRING,
KGRPE TYPE STRING,
KRELI TYPE STRING,
KDUPL TYPE STRING,
KRUEK TYPE STRING,
KOUPD TYPE STRING,
SOSTA TYPE STRING,
KOFRS TYPE STRING,
KALSM TYPE STRING,
KZNEP TYPE STRING,
KOAID TYPE STRING,
KKOPF TYPE STRING,
KPOSI TYPE STRING,
KNEGA TYPE STRING,
TXPRF TYPE STRING,
KSTPR TYPE STRING,
KAEND_BTR TYPE STRING,
KAEND_WRT TYPE STRING,
KAEND_UFK TYPE STRING,
KAEND_RCH TYPE STRING,
KAEND_LOE TYPE STRING,
KAEND_MEH TYPE STRING,
IDXUP TYPE STRING,
RUKOR TYPE STRING,
BOVER TYPE STRING,
KPRDT TYPE STRING,
STFKZ TYPE STRING,
PRECH TYPE STRING,
BNKWE TYPE STRING,
AKTKO TYPE STRING,
VKKAL TYPE STRING,
VKOBL TYPE STRING,
RKAPPL TYPE STRING,
RKSCHL TYPE STRING,
BERGL TYPE STRING,
VHART TYPE STRING,
RDIFA TYPE STRING,
KFKIV TYPE STRING,
KVARC TYPE STRING,
KMENG TYPE STRING,
GRLNR_LONG TYPE STRING,
KOFRS_LONG TYPE STRING,END OF T_EKKO_STR. DATA: WA_E1685A_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_E1685A_STR-KRECH sy-vline
WA_E1685A_STR-KZBZG sy-vline
WA_E1685A_STR-KNTYP sy-vline
WA_E1685A_STR-KONAU sy-vline
WA_E1685A_STR-KMANU sy-vline
WA_E1685A_STR-GRZGF sy-vline
WA_E1685A_STR-GRLNR sy-vline
WA_E1685A_STR-GRMEN sy-vline
WA_E1685A_STR-GANZZ sy-vline
WA_E1685A_STR-KGRPE sy-vline
WA_E1685A_STR-KRELI sy-vline
WA_E1685A_STR-KDUPL sy-vline
WA_E1685A_STR-KRUEK sy-vline
WA_E1685A_STR-KOUPD sy-vline
WA_E1685A_STR-SOSTA sy-vline
WA_E1685A_STR-KOFRS sy-vline
WA_E1685A_STR-KALSM sy-vline
WA_E1685A_STR-KZNEP sy-vline
WA_E1685A_STR-KOAID sy-vline
WA_E1685A_STR-KKOPF sy-vline
WA_E1685A_STR-KPOSI sy-vline
WA_E1685A_STR-KNEGA sy-vline
WA_E1685A_STR-TXPRF sy-vline
WA_E1685A_STR-KSTPR sy-vline
WA_E1685A_STR-KAEND_BTR sy-vline
WA_E1685A_STR-KAEND_WRT sy-vline
WA_E1685A_STR-KAEND_UFK sy-vline
WA_E1685A_STR-KAEND_RCH sy-vline
WA_E1685A_STR-KAEND_LOE sy-vline
WA_E1685A_STR-KAEND_MEH sy-vline
WA_E1685A_STR-IDXUP sy-vline
WA_E1685A_STR-RUKOR sy-vline
WA_E1685A_STR-BOVER sy-vline
WA_E1685A_STR-KPRDT sy-vline
WA_E1685A_STR-STFKZ sy-vline
WA_E1685A_STR-PRECH sy-vline
WA_E1685A_STR-BNKWE sy-vline
WA_E1685A_STR-AKTKO sy-vline
WA_E1685A_STR-VKKAL sy-vline
WA_E1685A_STR-VKOBL sy-vline
WA_E1685A_STR-RKAPPL sy-vline
WA_E1685A_STR-RKSCHL sy-vline
WA_E1685A_STR-BERGL sy-vline
WA_E1685A_STR-VHART sy-vline
WA_E1685A_STR-RDIFA sy-vline
WA_E1685A_STR-KFKIV sy-vline
WA_E1685A_STR-KVARC sy-vline
WA_E1685A_STR-KMENG sy-vline
WA_E1685A_STR-GRLNR_LONG sy-vline
WA_E1685A_STR-KOFRS_LONG sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.