ABAP Select data from SAP table E070CTV into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP E070CTV table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to E070CTV. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the E070CTV table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_E070CTV TYPE STANDARD TABLE OF E070CTV,
      WA_E070CTV TYPE E070CTV,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <E070CTV> TYPE E070CTV.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_E070CTV.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM E070CTV
  INTO TABLE IT_E070CTV.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM E070CTV
*  INTO TABLE @DATA(IT_E070CTV2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_E070CTV INDEX 1 INTO DATA(WA_E070CTV2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_E070CTV ASSIGNING <E070CTV>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<E070CTV>-TRKORR = 1.
<E070CTV>-TRFUNCTION = 1.
<E070CTV>-TRSTATUS = 1.
<E070CTV>-TARSYSTEM = 1.
<E070CTV>-AS4USER = 1.
ENDLOOP.

LOOP AT IT_E070CTV INTO WA_E070CTV.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_E070CTV-AS4DATE, sy-vline,
WA_E070CTV-AS4TIME, sy-vline,
WA_E070CTV-STRKORR, sy-vline,
WA_E070CTV-LANGU, sy-vline,
WA_E070CTV-AS4TEXT, sy-vline,
WA_E070CTV-CLIENT, sy-vline.
ENDLOOP. *Add any further fields from structure WA_E070CTV you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_E070CTV TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_E070CTV INTO WA_E070CTV. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ISOLA, internal->external for field LANGU CALL FUNCTION 'CONVERSION_EXIT_ISOLA_OUTPUT' EXPORTING input = WA_E070CTV-LANGU IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_E070CTV-LANGU.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_E070CTV_STR,
TRKORR TYPE STRING,
TRFUNCTION TYPE STRING,
TRSTATUS TYPE STRING,
TARSYSTEM TYPE STRING,
AS4USER TYPE STRING,
AS4DATE TYPE STRING,
AS4TIME TYPE STRING,
STRKORR TYPE STRING,
LANGU TYPE STRING,
AS4TEXT TYPE STRING,
CLIENT TYPE STRING,
TARCLIENT TYPE STRING,END OF T_EKKO_STR. DATA: WA_E070CTV_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_E070CTV_STR-TRKORR sy-vline
WA_E070CTV_STR-TRFUNCTION sy-vline
WA_E070CTV_STR-TRSTATUS sy-vline
WA_E070CTV_STR-TARSYSTEM sy-vline
WA_E070CTV_STR-AS4USER sy-vline
WA_E070CTV_STR-AS4DATE sy-vline
WA_E070CTV_STR-AS4TIME sy-vline
WA_E070CTV_STR-STRKORR sy-vline
WA_E070CTV_STR-LANGU sy-vline
WA_E070CTV_STR-AS4TEXT sy-vline
WA_E070CTV_STR-CLIENT sy-vline
WA_E070CTV_STR-TARCLIENT sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.