ABAP Select data from SAP table DPWTY_S_MGANR into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP DPWTY_S_MGANR table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to DPWTY_S_MGANR. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the DPWTY_S_MGANR table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_DPWTY_S_MGANR TYPE STANDARD TABLE OF DPWTY_S_MGANR,
      WA_DPWTY_S_MGANR TYPE DPWTY_S_MGANR,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <DPWTY_S_MGANR> TYPE DPWTY_S_MGANR.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_DPWTY_S_MGANR.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM DPWTY_S_MGANR
  INTO TABLE IT_DPWTY_S_MGANR.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM DPWTY_S_MGANR
*  INTO TABLE @DATA(IT_DPWTY_S_MGANR2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_DPWTY_S_MGANR INDEX 1 INTO DATA(WA_DPWTY_S_MGANR2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_DPWTY_S_MGANR ASSIGNING <DPWTY_S_MGANR>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<DPWTY_S_MGANR>-GUID = 1.
<DPWTY_S_MGANR>-LEVEL = 1.
<DPWTY_S_MGANR>-MGANR = 1.
<DPWTY_S_MGANR>-SPRAS = 1.
<DPWTY_S_MGANR>-GAKTX = 1.
ENDLOOP.

LOOP AT IT_DPWTY_S_MGANR INTO WA_DPWTY_S_MGANR.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_DPWTY_S_MGANR-GWLDT, sy-vline,
WA_DPWTY_S_MGANR-GWLEN, sy-vline,
WA_DPWTY_S_MGANR-GAART, sy-vline,
WA_DPWTY_S_MGANR-MGPOS, sy-vline,
ENDLOOP. *Add any further fields from structure WA_DPWTY_S_MGANR you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_DPWTY_S_MGANR TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_DPWTY_S_MGANR INTO WA_DPWTY_S_MGANR. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field MGANR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_DPWTY_S_MGANR-MGANR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_DPWTY_S_MGANR-MGANR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ISOLA, internal->external for field SPRAS CALL FUNCTION 'CONVERSION_EXIT_ISOLA_OUTPUT' EXPORTING input = WA_DPWTY_S_MGANR-SPRAS IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_DPWTY_S_MGANR-SPRAS.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_DPWTY_S_MGANR_STR,
GUID TYPE STRING,
LEVEL TYPE STRING,
MGANR TYPE STRING,
SPRAS TYPE STRING,
GAKTX TYPE STRING,
GWLDT TYPE STRING,
GWLEN TYPE STRING,
GAART TYPE STRING,
MGPOS TYPE STRING,END OF T_EKKO_STR. DATA: WA_DPWTY_S_MGANR_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_DPWTY_S_MGANR_STR-GUID sy-vline
WA_DPWTY_S_MGANR_STR-LEVEL sy-vline
WA_DPWTY_S_MGANR_STR-MGANR sy-vline
WA_DPWTY_S_MGANR_STR-SPRAS sy-vline
WA_DPWTY_S_MGANR_STR-GAKTX sy-vline
WA_DPWTY_S_MGANR_STR-GWLDT sy-vline
WA_DPWTY_S_MGANR_STR-GWLEN sy-vline
WA_DPWTY_S_MGANR_STR-GAART sy-vline
WA_DPWTY_S_MGANR_STR-MGPOS sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.