ABAP Select data from SAP table DPR_OBJLINK_SC into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP DPR_OBJLINK_SC table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to DPR_OBJLINK_SC. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the DPR_OBJLINK_SC table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_DPR_OBJLINK_SC TYPE STANDARD TABLE OF DPR_OBJLINK_SC,
      WA_DPR_OBJLINK_SC TYPE DPR_OBJLINK_SC,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <DPR_OBJLINK_SC> TYPE DPR_OBJLINK_SC.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_DPR_OBJLINK_SC.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM DPR_OBJLINK_SC
  INTO TABLE IT_DPR_OBJLINK_SC.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM DPR_OBJLINK_SC
*  INTO TABLE @DATA(IT_DPR_OBJLINK_SC2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_DPR_OBJLINK_SC INDEX 1 INTO DATA(WA_DPR_OBJLINK_SC2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_DPR_OBJLINK_SC ASSIGNING <DPR_OBJLINK_SC>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<DPR_OBJLINK_SC>-CLIENT = 1.
<DPR_OBJLINK_SC>-GUID = 1.
<DPR_OBJLINK_SC>-OBJECT_TYPE = 1.
<DPR_OBJLINK_SC>-PROJECT_GUID = 1.
<DPR_OBJLINK_SC>-TASK_GUID = 1.
ENDLOOP.

LOOP AT IT_DPR_OBJLINK_SC INTO WA_DPR_OBJLINK_SC.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_DPR_OBJLINK_SC-INT_ID, sy-vline,
WA_DPR_OBJLINK_SC-EXT_ID, sy-vline,
WA_DPR_OBJLINK_SC-CREATED_BY, sy-vline,
WA_DPR_OBJLINK_SC-CREATED_ON, sy-vline,
WA_DPR_OBJLINK_SC-CHANGED_BY, sy-vline,
WA_DPR_OBJLINK_SC-CHANGED_ON, sy-vline.
ENDLOOP. *Add any further fields from structure WA_DPR_OBJLINK_SC you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_DPR_OBJLINK_SC TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_DPR_OBJLINK_SC INTO WA_DPR_OBJLINK_SC. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit DPRCE, internal->external for field PROJECT_GUID CALL FUNCTION 'CONVERSION_EXIT_DPRCE_OUTPUT' EXPORTING input = WA_DPR_OBJLINK_SC-PROJECT_GUID IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_DPR_OBJLINK_SC-PROJECT_GUID.
WRITE:/ 'New Value:', ld_input.

*Conversion exit DPRCE, internal->external for field TASK_GUID CALL FUNCTION 'CONVERSION_EXIT_DPRCE_OUTPUT' EXPORTING input = WA_DPR_OBJLINK_SC-TASK_GUID IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_DPR_OBJLINK_SC-TASK_GUID.
WRITE:/ 'New Value:', ld_input.

*Conversion exit TSTPS, internal->external for field CREATED_ON CALL FUNCTION 'CONVERSION_EXIT_TSTPS_OUTPUT' EXPORTING input = WA_DPR_OBJLINK_SC-CREATED_ON IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_DPR_OBJLINK_SC-CREATED_ON.
WRITE:/ 'New Value:', ld_input.

*Conversion exit TSTPS, internal->external for field CHANGED_ON CALL FUNCTION 'CONVERSION_EXIT_TSTPS_OUTPUT' EXPORTING input = WA_DPR_OBJLINK_SC-CHANGED_ON IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_DPR_OBJLINK_SC-CHANGED_ON.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field REQUESTED_UNIT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_DPR_OBJLINK_SC-REQUESTED_UNIT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_DPR_OBJLINK_SC-REQUESTED_UNIT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit TSTPS, internal->external for field REQUESTED_BEGIN CALL FUNCTION 'CONVERSION_EXIT_TSTPS_OUTPUT' EXPORTING input = WA_DPR_OBJLINK_SC-REQUESTED_BEGIN IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_DPR_OBJLINK_SC-REQUESTED_BEGIN.
WRITE:/ 'New Value:', ld_input.

*Conversion exit TSTPS, internal->external for field REQUESTED_FINISH CALL FUNCTION 'CONVERSION_EXIT_TSTPS_OUTPUT' EXPORTING input = WA_DPR_OBJLINK_SC-REQUESTED_FINISH IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_DPR_OBJLINK_SC-REQUESTED_FINISH.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_DPR_OBJLINK_SC_STR,
CLIENT TYPE STRING,
GUID TYPE STRING,
OBJECT_TYPE TYPE STRING,
PROJECT_GUID TYPE STRING,
TASK_GUID TYPE STRING,
INT_ID TYPE STRING,
EXT_ID TYPE STRING,
CREATED_BY TYPE STRING,
CREATED_ON TYPE STRING,
CHANGED_BY TYPE STRING,
CHANGED_ON TYPE STRING,
NOTE TYPE STRING,
INT_NOTE TYPE STRING,
LOGSYS TYPE STRING,
BUPA_LINK_GUID TYPE STRING,
REQUESTED_QTY TYPE STRING,
REQUESTED_UNIT TYPE STRING,
TYPE_CODE TYPE STRING,
PROD_CATEGORY TYPE STRING,
REQUESTED_BEGIN TYPE STRING,
REQUESTED_FINISH TYPE STRING,
CANCEL_INDICATOR TYPE STRING,
VERSION_TYPE TYPE STRING,END OF T_EKKO_STR. DATA: WA_DPR_OBJLINK_SC_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_DPR_OBJLINK_SC_STR-CLIENT sy-vline
WA_DPR_OBJLINK_SC_STR-GUID sy-vline
WA_DPR_OBJLINK_SC_STR-OBJECT_TYPE sy-vline
WA_DPR_OBJLINK_SC_STR-PROJECT_GUID sy-vline
WA_DPR_OBJLINK_SC_STR-TASK_GUID sy-vline
WA_DPR_OBJLINK_SC_STR-INT_ID sy-vline
WA_DPR_OBJLINK_SC_STR-EXT_ID sy-vline
WA_DPR_OBJLINK_SC_STR-CREATED_BY sy-vline
WA_DPR_OBJLINK_SC_STR-CREATED_ON sy-vline
WA_DPR_OBJLINK_SC_STR-CHANGED_BY sy-vline
WA_DPR_OBJLINK_SC_STR-CHANGED_ON sy-vline
WA_DPR_OBJLINK_SC_STR-NOTE sy-vline
WA_DPR_OBJLINK_SC_STR-INT_NOTE sy-vline
WA_DPR_OBJLINK_SC_STR-LOGSYS sy-vline
WA_DPR_OBJLINK_SC_STR-BUPA_LINK_GUID sy-vline
WA_DPR_OBJLINK_SC_STR-REQUESTED_QTY sy-vline
WA_DPR_OBJLINK_SC_STR-REQUESTED_UNIT sy-vline
WA_DPR_OBJLINK_SC_STR-TYPE_CODE sy-vline
WA_DPR_OBJLINK_SC_STR-PROD_CATEGORY sy-vline
WA_DPR_OBJLINK_SC_STR-REQUESTED_BEGIN sy-vline
WA_DPR_OBJLINK_SC_STR-REQUESTED_FINISH sy-vline
WA_DPR_OBJLINK_SC_STR-CANCEL_INDICATOR sy-vline
WA_DPR_OBJLINK_SC_STR-VERSION_TYPE sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.