ABAP Select data from SAP table DMEE_SCREEN_FIELDS into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP DMEE_SCREEN_FIELDS table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to DMEE_SCREEN_FIELDS. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the DMEE_SCREEN_FIELDS table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_DMEE_SCREEN_FIELDS TYPE STANDARD TABLE OF DMEE_SCREEN_FIELDS,
      WA_DMEE_SCREEN_FIELDS TYPE DMEE_SCREEN_FIELDS,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <DMEE_SCREEN_FIELDS> TYPE DMEE_SCREEN_FIELDS.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_DMEE_SCREEN_FIELDS.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM DMEE_SCREEN_FIELDS
  INTO TABLE IT_DMEE_SCREEN_FIELDS.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM DMEE_SCREEN_FIELDS
*  INTO TABLE @DATA(IT_DMEE_SCREEN_FIELDS2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_DMEE_SCREEN_FIELDS INDEX 1 INTO DATA(WA_DMEE_SCREEN_FIELDS2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_DMEE_SCREEN_FIELDS ASSIGNING <DMEE_SCREEN_FIELDS>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<DMEE_SCREEN_FIELDS>-REPL_CHAR = 1.
<DMEE_SCREEN_FIELDS>-RFFO_TAB = 1.
<DMEE_SCREEN_FIELDS>-RFFO_FLD = 1.
<DMEE_SCREEN_FIELDS>-REPL_ZERO = 1.
<DMEE_SCREEN_FIELDS>-CONV_NUMC = 1.
ENDLOOP.

LOOP AT IT_DMEE_SCREEN_FIELDS INTO WA_DMEE_SCREEN_FIELDS.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_DMEE_SCREEN_FIELDS-REM_CHAR, sy-vline,
WA_DMEE_SCREEN_FIELDS-CHARSET_EXCL, sy-vline,
WA_DMEE_SCREEN_FIELDS-XML_TRANSFORM, sy-vline,
WA_DMEE_SCREEN_FIELDS-VERSION_TEXT, sy-vline,
WA_DMEE_SCREEN_FIELDS-VAR_OPERATION, sy-vline,
WA_DMEE_SCREEN_FIELDS-VAR_OPERATION2, sy-vline.
ENDLOOP. *Add any further fields from structure WA_DMEE_SCREEN_FIELDS you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_DMEE_SCREEN_FIELDS TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_DMEE_SCREEN_FIELDS INTO WA_DMEE_SCREEN_FIELDS. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_DMEE_SCREEN_FIELDS_STR,
REPL_CHAR TYPE STRING,
RFFO_TAB TYPE STRING,
RFFO_FLD TYPE STRING,
REPL_ZERO TYPE STRING,
CONV_NUMC TYPE STRING,
REM_CHAR TYPE STRING,
CHARSET_EXCL TYPE STRING,
XML_TRANSFORM TYPE STRING,
VERSION_TEXT TYPE STRING,
VAR_OPERATION TYPE STRING,
VAR_OPERATION2 TYPE STRING,
VAR_NAME TYPE STRING,
VAR_VALUE_L TYPE STRING,
VAR_VALUE2 TYPE STRING,
VAR_CALC_SRC_TYPE_L TYPE STRING,
VAR_CALC_SRC_TYPE2 TYPE STRING,
REF_NODE_ATTR_L TYPE STRING,
REF_NODE_ATTR2 TYPE STRING,END OF T_EKKO_STR. DATA: WA_DMEE_SCREEN_FIELDS_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_DMEE_SCREEN_FIELDS_STR-REPL_CHAR sy-vline
WA_DMEE_SCREEN_FIELDS_STR-RFFO_TAB sy-vline
WA_DMEE_SCREEN_FIELDS_STR-RFFO_FLD sy-vline
WA_DMEE_SCREEN_FIELDS_STR-REPL_ZERO sy-vline
WA_DMEE_SCREEN_FIELDS_STR-CONV_NUMC sy-vline
WA_DMEE_SCREEN_FIELDS_STR-REM_CHAR sy-vline
WA_DMEE_SCREEN_FIELDS_STR-CHARSET_EXCL sy-vline
WA_DMEE_SCREEN_FIELDS_STR-XML_TRANSFORM sy-vline
WA_DMEE_SCREEN_FIELDS_STR-VERSION_TEXT sy-vline
WA_DMEE_SCREEN_FIELDS_STR-VAR_OPERATION sy-vline
WA_DMEE_SCREEN_FIELDS_STR-VAR_OPERATION2 sy-vline
WA_DMEE_SCREEN_FIELDS_STR-VAR_NAME sy-vline
WA_DMEE_SCREEN_FIELDS_STR-VAR_VALUE_L sy-vline
WA_DMEE_SCREEN_FIELDS_STR-VAR_VALUE2 sy-vline
WA_DMEE_SCREEN_FIELDS_STR-VAR_CALC_SRC_TYPE_L sy-vline
WA_DMEE_SCREEN_FIELDS_STR-VAR_CALC_SRC_TYPE2 sy-vline
WA_DMEE_SCREEN_FIELDS_STR-REF_NODE_ATTR_L sy-vline
WA_DMEE_SCREEN_FIELDS_STR-REF_NODE_ATTR2 sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.