ABAP Select data from SAP table DM45V_OLD into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP DM45V_OLD table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to DM45V_OLD. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the DM45V_OLD table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_DM45V_OLD TYPE STANDARD TABLE OF DM45V_OLD,
      WA_DM45V_OLD TYPE DM45V_OLD,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <DM45V_OLD> TYPE DM45V_OLD.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_DM45V_OLD.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM DM45V_OLD
  INTO TABLE IT_DM45V_OLD.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM DM45V_OLD
*  INTO TABLE @DATA(IT_DM45V_OLD2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_DM45V_OLD INDEX 1 INTO DATA(WA_DM45V_OLD2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_DM45V_OLD ASSIGNING <DM45V_OLD>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<DM45V_OLD>-ENTID = 1.
<DM45V_OLD>-AS4LOCAL = 1.
<DM45V_OLD>-SPEZID = 1.
<DM45V_OLD>-SPRACHE = 1.
<DM45V_OLD>-FLG_DEF = 1.
ENDLOOP.

LOOP AT IT_DM45V_OLD INTO WA_DM45V_OLD.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_DM45V_OLD-FLG_COM, sy-vline,
WA_DM45V_OLD-COMPLETE, sy-vline,
WA_DM45V_OLD-DISJUNCT, sy-vline,
WA_DM45V_OLD-FSTUSER, sy-vline,
WA_DM45V_OLD-FSTDATE, sy-vline,
WA_DM45V_OLD-FSTTIME, sy-vline.
ENDLOOP. *Add any further fields from structure WA_DM45V_OLD you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_DM45V_OLD TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_DM45V_OLD INTO WA_DM45V_OLD. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_DM45V_OLD_STR,
ENTID TYPE STRING,
AS4LOCAL TYPE STRING,
SPEZID TYPE STRING,
SPRACHE TYPE STRING,
FLG_DEF TYPE STRING,
FLG_COM TYPE STRING,
COMPLETE TYPE STRING,
DISJUNCT TYPE STRING,
FSTUSER TYPE STRING,
FSTDATE TYPE STRING,
FSTTIME TYPE STRING,
LSTUSER TYPE STRING,
LSTDATE TYPE STRING,
LSTTIME TYPE STRING,
LOESCHZ TYPE STRING,
LANGBEZ TYPE STRING,END OF T_EKKO_STR. DATA: WA_DM45V_OLD_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_DM45V_OLD_STR-ENTID sy-vline
WA_DM45V_OLD_STR-AS4LOCAL sy-vline
WA_DM45V_OLD_STR-SPEZID sy-vline
WA_DM45V_OLD_STR-SPRACHE sy-vline
WA_DM45V_OLD_STR-FLG_DEF sy-vline
WA_DM45V_OLD_STR-FLG_COM sy-vline
WA_DM45V_OLD_STR-COMPLETE sy-vline
WA_DM45V_OLD_STR-DISJUNCT sy-vline
WA_DM45V_OLD_STR-FSTUSER sy-vline
WA_DM45V_OLD_STR-FSTDATE sy-vline
WA_DM45V_OLD_STR-FSTTIME sy-vline
WA_DM45V_OLD_STR-LSTUSER sy-vline
WA_DM45V_OLD_STR-LSTDATE sy-vline
WA_DM45V_OLD_STR-LSTTIME sy-vline
WA_DM45V_OLD_STR-LOESCHZ sy-vline
WA_DM45V_OLD_STR-LANGBEZ sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.