ABAP Select data from SAP table DM41S into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP DM41S table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to DM41S. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the DM41S table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_DM41S TYPE STANDARD TABLE OF DM41S,
      WA_DM41S TYPE DM41S,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <DM41S> TYPE DM41S.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_DM41S.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM DM41S
  INTO TABLE IT_DM41S.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM DM41S
*  INTO TABLE @DATA(IT_DM41S2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_DM41S INDEX 1 INTO DATA(WA_DM41S2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_DM41S ASSIGNING <DM41S>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<DM41S>-DMOID = 1.
<DM41S>-AS4LOCAL = 1.
<DM41S>-OBJID = 1.
<DM41S>-OBJTYP = 1.
<DM41S>-HIERPOS = 1.
ENDLOOP.

LOOP AT IT_DM41S INTO WA_DM41S.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_DM41S-XPOS, sy-vline,
WA_DM41S-YPOS, sy-vline,
WA_DM41S-WIDTH, sy-vline,
WA_DM41S-HEIGHT, sy-vline,
WA_DM41S-FSTUSER, sy-vline,
WA_DM41S-FSTDATE, sy-vline.
ENDLOOP. *Add any further fields from structure WA_DM41S you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_DM41S TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_DM41S INTO WA_DM41S. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_DM41S_STR,
DMOID TYPE STRING,
AS4LOCAL TYPE STRING,
OBJID TYPE STRING,
OBJTYP TYPE STRING,
HIERPOS TYPE STRING,
XPOS TYPE STRING,
YPOS TYPE STRING,
WIDTH TYPE STRING,
HEIGHT TYPE STRING,
FSTUSER TYPE STRING,
FSTDATE TYPE STRING,
FSTTIME TYPE STRING,
LSTUSER TYPE STRING,
LSTDATE TYPE STRING,
LSTTIME TYPE STRING,
LOESCHZ TYPE STRING,
INSTDVIEW TYPE STRING,END OF T_EKKO_STR. DATA: WA_DM41S_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_DM41S_STR-DMOID sy-vline
WA_DM41S_STR-AS4LOCAL sy-vline
WA_DM41S_STR-OBJID sy-vline
WA_DM41S_STR-OBJTYP sy-vline
WA_DM41S_STR-HIERPOS sy-vline
WA_DM41S_STR-XPOS sy-vline
WA_DM41S_STR-YPOS sy-vline
WA_DM41S_STR-WIDTH sy-vline
WA_DM41S_STR-HEIGHT sy-vline
WA_DM41S_STR-FSTUSER sy-vline
WA_DM41S_STR-FSTDATE sy-vline
WA_DM41S_STR-FSTTIME sy-vline
WA_DM41S_STR-LSTUSER sy-vline
WA_DM41S_STR-LSTDATE sy-vline
WA_DM41S_STR-LSTTIME sy-vline
WA_DM41S_STR-LOESCHZ sy-vline
WA_DM41S_STR-INSTDVIEW sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.