ABAP Select data from SAP table DIMSP_S_COUNTER_READING_DATA into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP DIMSP_S_COUNTER_READING_DATA table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to DIMSP_S_COUNTER_READING_DATA. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the DIMSP_S_COUNTER_READING_DATA table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_DIMSP_S_COUNTER_READING_DATA TYPE STANDARD TABLE OF DIMSP_S_COUNTER_READING_DATA,
      WA_DIMSP_S_COUNTER_READING_DATA TYPE DIMSP_S_COUNTER_READING_DATA,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <DIMSP_S_COUNTER_READING_DATA> TYPE DIMSP_S_COUNTER_READING_DATA.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_DIMSP_S_COUNTER_READING_DATA.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM DIMSP_S_COUNTER_READING_DATA
  INTO TABLE IT_DIMSP_S_COUNTER_READING_DATA.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM DIMSP_S_COUNTER_READING_DATA
*  INTO TABLE @DATA(IT_DIMSP_S_COUNTER_READING_DATA2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_DIMSP_S_COUNTER_READING_DATA INDEX 1 INTO DATA(WA_DIMSP_S_COUNTER_READING_DATA2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_DIMSP_S_COUNTER_READING_DATA ASSIGNING <DIMSP_S_COUNTER_READING_DATA>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<DIMSP_S_COUNTER_READING_DATA>-COUNTER_REF = 1.
<DIMSP_S_COUNTER_READING_DATA>-COUNTER_DESCRIPT = 1.
<DIMSP_S_COUNTER_READING_DATA>-CNT_READING_SI = 1.
<DIMSP_S_COUNTER_READING_DATA>-SI_UNIT = 1.
<DIMSP_S_COUNTER_READING_DATA>-COUNTER_UNIT = 1.
ENDLOOP.

LOOP AT IT_DIMSP_S_COUNTER_READING_DATA INTO WA_DIMSP_S_COUNTER_READING_DATA.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_DIMSP_S_COUNTER_READING_DATA-MEAS_DATE_TIME, sy-vline,
WA_DIMSP_S_COUNTER_READING_DATA-CNT_CNSMPT_SI_PYEAR, sy-vline,
WA_DIMSP_S_COUNTER_READING_DATA-AVG_PERFORM_DATA, sy-vline,
ENDLOOP. *Add any further fields from structure WA_DIMSP_S_COUNTER_READING_DATA you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_DIMSP_S_COUNTER_READING_DATA TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_DIMSP_S_COUNTER_READING_DATA INTO WA_DIMSP_S_COUNTER_READING_DATA. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field COUNTER_REF CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_DIMSP_S_COUNTER_READING_DATA-COUNTER_REF IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_DIMSP_S_COUNTER_READING_DATA-COUNTER_REF.
WRITE:/ 'New Value:', ld_input.

*Conversion exit LUNIT, internal->external for field SI_UNIT CALL FUNCTION 'CONVERSION_EXIT_LUNIT_OUTPUT' EXPORTING input = WA_DIMSP_S_COUNTER_READING_DATA-SI_UNIT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_DIMSP_S_COUNTER_READING_DATA-SI_UNIT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit LUNIT, internal->external for field COUNTER_UNIT CALL FUNCTION 'CONVERSION_EXIT_LUNIT_OUTPUT' EXPORTING input = WA_DIMSP_S_COUNTER_READING_DATA-COUNTER_UNIT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_DIMSP_S_COUNTER_READING_DATA-COUNTER_UNIT.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_DIMSP_S_COUNTER_READING_DATA_STR,
COUNTER_REF TYPE STRING,
COUNTER_DESCRIPT TYPE STRING,
CNT_READING_SI TYPE STRING,
SI_UNIT TYPE STRING,
COUNTER_UNIT TYPE STRING,
MEAS_DATE_TIME TYPE STRING,
CNT_CNSMPT_SI_PYEAR TYPE STRING,
AVG_PERFORM_DATA TYPE STRING,END OF T_EKKO_STR. DATA: WA_DIMSP_S_COUNTER_READING_DATA_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_DIMSP_S_COUNTER_READING_DATA_STR-COUNTER_REF sy-vline
WA_DIMSP_S_COUNTER_READING_DATA_STR-COUNTER_DESCRIPT sy-vline
WA_DIMSP_S_COUNTER_READING_DATA_STR-CNT_READING_SI sy-vline
WA_DIMSP_S_COUNTER_READING_DATA_STR-SI_UNIT sy-vline
WA_DIMSP_S_COUNTER_READING_DATA_STR-COUNTER_UNIT sy-vline
WA_DIMSP_S_COUNTER_READING_DATA_STR-MEAS_DATE_TIME sy-vline
WA_DIMSP_S_COUNTER_READING_DATA_STR-CNT_CNSMPT_SI_PYEAR sy-vline
WA_DIMSP_S_COUNTER_READING_DATA_STR-AVG_PERFORM_DATA sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.