ABAP Select data from SAP table DIIMPT_R into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP DIIMPT_R table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to DIIMPT_R. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the DIIMPT_R table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_DIIMPT_R TYPE STANDARD TABLE OF DIIMPT_R,
      WA_DIIMPT_R TYPE DIIMPT_R,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <DIIMPT_R> TYPE DIIMPT_R.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_DIIMPT_R.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM DIIMPT_R
  INTO TABLE IT_DIIMPT_R.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM DIIMPT_R
*  INTO TABLE @DATA(IT_DIIMPT_R2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_DIIMPT_R INDEX 1 INTO DATA(WA_DIIMPT_R2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_DIIMPT_R ASSIGNING <DIIMPT_R>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<DIIMPT_R>-MANDT = 1.
<DIIMPT_R>-POINT = 1.
<DIIMPT_R>-MPOBJ = 1.
<DIIMPT_R>-PSORT = 1.
<DIIMPT_R>-PSORTR = 1.
ENDLOOP.

LOOP AT IT_DIIMPT_R INTO WA_DIIMPT_R.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_DIIMPT_R-PTTXT, sy-vline,
WA_DIIMPT_R-MLANG, sy-vline,
WA_DIIMPT_R-KZLTX, sy-vline,
WA_DIIMPT_R-MPTYP, sy-vline,
WA_DIIMPT_R-IRFMP, sy-vline,
WA_DIIMPT_R-ERDAT, sy-vline.
ENDLOOP. *Add any further fields from structure WA_DIIMPT_R you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_DIIMPT_R TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_DIIMPT_R INTO WA_DIIMPT_R. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field POINT CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_DIIMPT_R-POINT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_DIIMPT_R-POINT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ISOLA, internal->external for field MLANG CALL FUNCTION 'CONVERSION_EXIT_ISOLA_OUTPUT' EXPORTING input = WA_DIIMPT_R-MLANG IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_DIIMPT_R-MLANG.
WRITE:/ 'New Value:', ld_input.

*Conversion exit MATN1, internal->external for field LOCAS CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_DIIMPT_R-LOCAS IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_DIIMPT_R-LOCAS.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field REFMP CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_DIIMPT_R-REFMP IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_DIIMPT_R-REFMP.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ATINN, internal->external for field ATINN CALL FUNCTION 'CONVERSION_EXIT_ATINN_OUTPUT' EXPORTING input = WA_DIIMPT_R-ATINN IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_DIIMPT_R-ATINN.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field MRNGU CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_DIIMPT_R-MRNGU IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_DIIMPT_R-MRNGU.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field TRANS CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_DIIMPT_R-TRANS IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_DIIMPT_R-TRANS.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field LOGSYS CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_DIIMPT_R-LOGSYS IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_DIIMPT_R-LOGSYS.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field MSEHI CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_DIIMPT_R-MSEHI IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_DIIMPT_R-MSEHI.
WRITE:/ 'New Value:', ld_input.

*Conversion exit LUNIT, internal->external for field UNITC CALL FUNCTION 'CONVERSION_EXIT_LUNIT_OUTPUT' EXPORTING input = WA_DIIMPT_R-UNITC IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_DIIMPT_R-UNITC.
WRITE:/ 'New Value:', ld_input.

*Conversion exit LUNIT, internal->external for field UNITM CALL FUNCTION 'CONVERSION_EXIT_LUNIT_OUTPUT' EXPORTING input = WA_DIIMPT_R-UNITM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_DIIMPT_R-UNITM.
WRITE:/ 'New Value:', ld_input.

*Conversion exit LUNIT, internal->external for field UNITS CALL FUNCTION 'CONVERSION_EXIT_LUNIT_OUTPUT' EXPORTING input = WA_DIIMPT_R-UNITS IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_DIIMPT_R-UNITS.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_DIIMPT_R_STR,
MANDT TYPE STRING,
POINT TYPE STRING,
MPOBJ TYPE STRING,
PSORT TYPE STRING,
PSORTR TYPE STRING,
PTTXT TYPE STRING,
MLANG TYPE STRING,
KZLTX TYPE STRING,
MPTYP TYPE STRING,
IRFMP TYPE STRING,
ERDAT TYPE STRING,
ERNAM TYPE STRING,
AEDAT TYPE STRING,
AENAM TYPE STRING,
BEGRU TYPE STRING,
INACT TYPE STRING,
LVORM TYPE STRING,
LOCAS TYPE STRING,
REFMP TYPE STRING,
ATINN TYPE STRING,
ATINNR TYPE STRING,
EXPON TYPE STRING,
DECIM TYPE STRING,
DESIR TYPE STRING,
DESIRI TYPE STRING,
DESIRR TYPE STRING,
DSTXT TYPE STRING,
DSTXTR TYPE STRING,
MRMIN TYPE STRING,
MRMINI TYPE STRING,
MRMAX TYPE STRING,
MRMAXI TYPE STRING,
MRNGU TYPE STRING,
INDCT TYPE STRING,
INDRV TYPE STRING,
INDTR TYPE STRING,
TRANS TYPE STRING,
CJUMP TYPE STRING,
CJUMPI TYPE STRING,
PYEAR TYPE STRING,
PYEARI TYPE STRING,
CODCT TYPE STRING,
CODGR TYPE STRING,
CODGRR TYPE STRING,
CDSUF TYPE STRING,
MODTR TYPE STRING,
INDTRR TYPE STRING,
LOGSYS TYPE STRING,
LOGSYS_CHG TYPE STRING,
ATNAM TYPE STRING,
ATFOR TYPE STRING,
ATVOR TYPE STRING,
MSEHI TYPE STRING,
ATDIM TYPE STRING,
ANZDZ TYPE STRING,
AUSWAHLMGE TYPE STRING,
DESIC TYPE STRING,
CJUMC TYPE STRING,
PYEAC TYPE STRING,
UNITC TYPE STRING,
MRMIC TYPE STRING,
MRMAC TYPE STRING,
UNITM TYPE STRING,
UNITS TYPE STRING,
TRPNR TYPE STRING,END OF T_EKKO_STR. DATA: WA_DIIMPT_R_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_DIIMPT_R_STR-MANDT sy-vline
WA_DIIMPT_R_STR-POINT sy-vline
WA_DIIMPT_R_STR-MPOBJ sy-vline
WA_DIIMPT_R_STR-PSORT sy-vline
WA_DIIMPT_R_STR-PSORTR sy-vline
WA_DIIMPT_R_STR-PTTXT sy-vline
WA_DIIMPT_R_STR-MLANG sy-vline
WA_DIIMPT_R_STR-KZLTX sy-vline
WA_DIIMPT_R_STR-MPTYP sy-vline
WA_DIIMPT_R_STR-IRFMP sy-vline
WA_DIIMPT_R_STR-ERDAT sy-vline
WA_DIIMPT_R_STR-ERNAM sy-vline
WA_DIIMPT_R_STR-AEDAT sy-vline
WA_DIIMPT_R_STR-AENAM sy-vline
WA_DIIMPT_R_STR-BEGRU sy-vline
WA_DIIMPT_R_STR-INACT sy-vline
WA_DIIMPT_R_STR-LVORM sy-vline
WA_DIIMPT_R_STR-LOCAS sy-vline
WA_DIIMPT_R_STR-REFMP sy-vline
WA_DIIMPT_R_STR-ATINN sy-vline
WA_DIIMPT_R_STR-ATINNR sy-vline
WA_DIIMPT_R_STR-EXPON sy-vline
WA_DIIMPT_R_STR-DECIM sy-vline
WA_DIIMPT_R_STR-DESIR sy-vline
WA_DIIMPT_R_STR-DESIRI sy-vline
WA_DIIMPT_R_STR-DESIRR sy-vline
WA_DIIMPT_R_STR-DSTXT sy-vline
WA_DIIMPT_R_STR-DSTXTR sy-vline
WA_DIIMPT_R_STR-MRMIN sy-vline
WA_DIIMPT_R_STR-MRMINI sy-vline
WA_DIIMPT_R_STR-MRMAX sy-vline
WA_DIIMPT_R_STR-MRMAXI sy-vline
WA_DIIMPT_R_STR-MRNGU sy-vline
WA_DIIMPT_R_STR-INDCT sy-vline
WA_DIIMPT_R_STR-INDRV sy-vline
WA_DIIMPT_R_STR-INDTR sy-vline
WA_DIIMPT_R_STR-TRANS sy-vline
WA_DIIMPT_R_STR-CJUMP sy-vline
WA_DIIMPT_R_STR-CJUMPI sy-vline
WA_DIIMPT_R_STR-PYEAR sy-vline
WA_DIIMPT_R_STR-PYEARI sy-vline
WA_DIIMPT_R_STR-CODCT sy-vline
WA_DIIMPT_R_STR-CODGR sy-vline
WA_DIIMPT_R_STR-CODGRR sy-vline
WA_DIIMPT_R_STR-CDSUF sy-vline
WA_DIIMPT_R_STR-MODTR sy-vline
WA_DIIMPT_R_STR-INDTRR sy-vline
WA_DIIMPT_R_STR-LOGSYS sy-vline
WA_DIIMPT_R_STR-LOGSYS_CHG sy-vline
WA_DIIMPT_R_STR-ATNAM sy-vline
WA_DIIMPT_R_STR-ATFOR sy-vline
WA_DIIMPT_R_STR-ATVOR sy-vline
WA_DIIMPT_R_STR-MSEHI sy-vline
WA_DIIMPT_R_STR-ATDIM sy-vline
WA_DIIMPT_R_STR-ANZDZ sy-vline
WA_DIIMPT_R_STR-AUSWAHLMGE sy-vline
WA_DIIMPT_R_STR-DESIC sy-vline
WA_DIIMPT_R_STR-CJUMC sy-vline
WA_DIIMPT_R_STR-PYEAC sy-vline
WA_DIIMPT_R_STR-UNITC sy-vline
WA_DIIMPT_R_STR-MRMIC sy-vline
WA_DIIMPT_R_STR-MRMAC sy-vline
WA_DIIMPT_R_STR-UNITM sy-vline
WA_DIIMPT_R_STR-UNITS sy-vline
WA_DIIMPT_R_STR-TRPNR sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.