ABAP Select data from SAP table DF17VD into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP DF17VD table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to DF17VD. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the DF17VD table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_DF17VD TYPE STANDARD TABLE OF DF17VD,
      WA_DF17VD TYPE DF17VD,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <DF17VD> TYPE DF17VD.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_DF17VD.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM DF17VD
  INTO TABLE IT_DF17VD.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM DF17VD
*  INTO TABLE @DATA(IT_DF17VD2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_DF17VD INDEX 1 INTO DATA(WA_DF17VD2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_DF17VD ASSIGNING <DF17VD>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<DF17VD>-IDENT = 1.
<DF17VD>-FSTUSER = 1.
<DF17VD>-FSTDATE = 1.
<DF17VD>-FSTTIME = 1.
<DF17VD>-LSTUSER = 1.
ENDLOOP.

LOOP AT IT_DF17VD INTO WA_DF17VD.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_DF17VD-LSTDATE, sy-vline,
WA_DF17VD-LSTTIME, sy-vline,
WA_DF17VD-RELE, sy-vline,
WA_DF17VD-LSTRELE, sy-vline,
WA_DF17VD-SYNCH, sy-vline,
WA_DF17VD-OBJ_TYPE, sy-vline.
ENDLOOP. *Add any further fields from structure WA_DF17VD you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_DF17VD TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_DF17VD INTO WA_DF17VD. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit RELE, internal->external for field RELE CALL FUNCTION 'CONVERSION_EXIT_RELE_OUTPUT' EXPORTING input = WA_DF17VD-RELE IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_DF17VD-RELE.
WRITE:/ 'New Value:', ld_input.

*Conversion exit RELE, internal->external for field LSTRELE CALL FUNCTION 'CONVERSION_EXIT_RELE_OUTPUT' EXPORTING input = WA_DF17VD-LSTRELE IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_DF17VD-LSTRELE.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ISOLA, internal->external for field LANGU CALL FUNCTION 'CONVERSION_EXIT_ISOLA_OUTPUT' EXPORTING input = WA_DF17VD-LANGU IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_DF17VD-LANGU.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_DF17VD_STR,
IDENT TYPE STRING,
FSTUSER TYPE STRING,
FSTDATE TYPE STRING,
FSTTIME TYPE STRING,
LSTUSER TYPE STRING,
LSTDATE TYPE STRING,
LSTTIME TYPE STRING,
RELE TYPE STRING,
LSTRELE TYPE STRING,
SYNCH TYPE STRING,
OBJ_TYPE TYPE STRING,
TSTAMP TYPE STRING,
LANGU TYPE STRING,
NAME TYPE STRING,
LONGNAME TYPE STRING,END OF T_EKKO_STR. DATA: WA_DF17VD_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_DF17VD_STR-IDENT sy-vline
WA_DF17VD_STR-FSTUSER sy-vline
WA_DF17VD_STR-FSTDATE sy-vline
WA_DF17VD_STR-FSTTIME sy-vline
WA_DF17VD_STR-LSTUSER sy-vline
WA_DF17VD_STR-LSTDATE sy-vline
WA_DF17VD_STR-LSTTIME sy-vline
WA_DF17VD_STR-RELE sy-vline
WA_DF17VD_STR-LSTRELE sy-vline
WA_DF17VD_STR-SYNCH sy-vline
WA_DF17VD_STR-OBJ_TYPE sy-vline
WA_DF17VD_STR-TSTAMP sy-vline
WA_DF17VD_STR-LANGU sy-vline
WA_DF17VD_STR-NAME sy-vline
WA_DF17VD_STR-LONGNAME sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.