ABAP Select data from SAP table DET_RMPUIOD into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP DET_RMPUIOD table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to DET_RMPUIOD. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the DET_RMPUIOD table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_DET_RMPUIOD TYPE STANDARD TABLE OF DET_RMPUIOD,
      WA_DET_RMPUIOD TYPE DET_RMPUIOD,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <DET_RMPUIOD> TYPE DET_RMPUIOD.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_DET_RMPUIOD.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM DET_RMPUIOD
  INTO TABLE IT_DET_RMPUIOD.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM DET_RMPUIOD
*  INTO TABLE @DATA(IT_DET_RMPUIOD2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_DET_RMPUIOD INDEX 1 INTO DATA(WA_DET_RMPUIOD2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_DET_RMPUIOD ASSIGNING <DET_RMPUIOD>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<DET_RMPUIOD>-WERKS = 1.
<DET_RMPUIOD>-MATNR = 1.
<DET_RMPUIOD>-MAKTX = 1.
<DET_RMPUIOD>-LGORT = 1.
<DET_RMPUIOD>-WMPPI = 1.
ENDLOOP.

LOOP AT IT_DET_RMPUIOD INTO WA_DET_RMPUIOD.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_DET_RMPUIOD-PRVBE, sy-vline,
WA_DET_RMPUIOD-KANBN, sy-vline,
WA_DET_RMPUIOD-DISKZ, sy-vline,
WA_DET_RMPUIOD-XCHPF, sy-vline,
WA_DET_RMPUIOD-XCHAR, sy-vline,
WA_DET_RMPUIOD-BWTTY, sy-vline.
ENDLOOP. *Add any further fields from structure WA_DET_RMPUIOD you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_DET_RMPUIOD TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_DET_RMPUIOD INTO WA_DET_RMPUIOD. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit MATN1, internal->external for field MATNR CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_DET_RMPUIOD-MATNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_DET_RMPUIOD-MATNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field LIFNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_DET_RMPUIOD-LIFNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_DET_RMPUIOD-LIFNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field KDAUF CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_DET_RMPUIOD-KDAUF IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_DET_RMPUIOD-KDAUF.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ABPSP, internal->external for field PSPEL CALL FUNCTION 'CONVERSION_EXIT_ABPSP_OUTPUT' EXPORTING input = WA_DET_RMPUIOD-PSPEL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_DET_RMPUIOD-PSPEL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field PLNUM CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_DET_RMPUIOD-PLNUM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_DET_RMPUIOD-PLNUM.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field AUFNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_DET_RMPUIOD-AUFNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_DET_RMPUIOD-AUFNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit MATN1, internal->external for field BAUGR CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_DET_RMPUIOD-BAUGR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_DET_RMPUIOD-BAUGR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field ERFME CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_DET_RMPUIOD-ERFME IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_DET_RMPUIOD-ERFME.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field MEINS CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_DET_RMPUIOD-MEINS IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_DET_RMPUIOD-MEINS.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field UNIT2 CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_DET_RMPUIOD-UNIT2 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_DET_RMPUIOD-UNIT2.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field UNIT3 CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_DET_RMPUIOD-UNIT3 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_DET_RMPUIOD-UNIT3.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field UNIT4 CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_DET_RMPUIOD-UNIT4 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_DET_RMPUIOD-UNIT4.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field UNIT5 CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_DET_RMPUIOD-UNIT5 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_DET_RMPUIOD-UNIT5.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field UNIT6 CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_DET_RMPUIOD-UNIT6 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_DET_RMPUIOD-UNIT6.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field UNIT7 CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_DET_RMPUIOD-UNIT7 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_DET_RMPUIOD-UNIT7.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field MEINS1 CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_DET_RMPUIOD-MEINS1 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_DET_RMPUIOD-MEINS1.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_DET_RMPUIOD_STR,
WERKS TYPE STRING,
MATNR TYPE STRING,
MAKTX TYPE STRING,
LGORT TYPE STRING,
WMPPI TYPE STRING,
PRVBE TYPE STRING,
KANBN TYPE STRING,
DISKZ TYPE STRING,
XCHPF TYPE STRING,
XCHAR TYPE STRING,
BWTTY TYPE STRING,
CHARG TYPE STRING,
SOBKZ TYPE STRING,
LIFNR TYPE STRING,
KDAUF TYPE STRING,
KDPOS TYPE STRING,
PSPEL TYPE STRING,
BERKZ TYPE STRING,
LGNUM TYPE STRING,
LGTYP TYPE STRING,
LGPLA TYPE STRING,
RSNUM TYPE STRING,
RSPOS TYPE STRING,
RSART TYPE STRING,
BDART TYPE STRING,
RQNUM TYPE STRING,
RQITM TYPE STRING,
LGPBE TYPE STRING,
LMINB TYPE STRING,
LBSTF TYPE STRING,
ARBPL TYPE STRING,
ARBTX TYPE STRING,
PLNUM TYPE STRING,
AUFNR TYPE STRING,
DAUTY TYPE STRING,
DISPO TYPE STRING,
FEVOR TYPE STRING,
VERID TYPE STRING,
MDV01 TYPE STRING,
MDV02 TYPE STRING,
LINTX TYPE STRING,
BAUGR TYPE STRING,
BAUTX TYPE STRING,
BDTER TYPE STRING,
SBTER TYPE STRING,
BDZTP TYPE STRING,
NBDMG TYPE STRING,
AVAIL TYPE STRING,
AVAIL_TOT TYPE STRING,
AVOVL TYPE STRING,
MISSQ TYPE STRING,
EQUAN TYPE STRING,
RMISS TYPE STRING,
EQUAN_BEA TYPE STRING,
ERFME TYPE STRING,
MARK TYPE STRING,
DETAIL_ICON TYPE STRING,
MEINS TYPE STRING,
DELB0 TYPE STRING,
NUMMER_DELB0 TYPE STRING,
LIGHT_ICON TYPE STRING,
UNIT2 TYPE STRING,
UNIT3 TYPE STRING,
UNIT4 TYPE STRING,
UNIT5 TYPE STRING,
UNIT6 TYPE STRING,
UNIT7 TYPE STRING,
MEINS1 TYPE STRING,
UMREN TYPE STRING,
UMREZ TYPE STRING,
KZWSO TYPE STRING,END OF T_EKKO_STR. DATA: WA_DET_RMPUIOD_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_DET_RMPUIOD_STR-WERKS sy-vline
WA_DET_RMPUIOD_STR-MATNR sy-vline
WA_DET_RMPUIOD_STR-MAKTX sy-vline
WA_DET_RMPUIOD_STR-LGORT sy-vline
WA_DET_RMPUIOD_STR-WMPPI sy-vline
WA_DET_RMPUIOD_STR-PRVBE sy-vline
WA_DET_RMPUIOD_STR-KANBN sy-vline
WA_DET_RMPUIOD_STR-DISKZ sy-vline
WA_DET_RMPUIOD_STR-XCHPF sy-vline
WA_DET_RMPUIOD_STR-XCHAR sy-vline
WA_DET_RMPUIOD_STR-BWTTY sy-vline
WA_DET_RMPUIOD_STR-CHARG sy-vline
WA_DET_RMPUIOD_STR-SOBKZ sy-vline
WA_DET_RMPUIOD_STR-LIFNR sy-vline
WA_DET_RMPUIOD_STR-KDAUF sy-vline
WA_DET_RMPUIOD_STR-KDPOS sy-vline
WA_DET_RMPUIOD_STR-PSPEL sy-vline
WA_DET_RMPUIOD_STR-BERKZ sy-vline
WA_DET_RMPUIOD_STR-LGNUM sy-vline
WA_DET_RMPUIOD_STR-LGTYP sy-vline
WA_DET_RMPUIOD_STR-LGPLA sy-vline
WA_DET_RMPUIOD_STR-RSNUM sy-vline
WA_DET_RMPUIOD_STR-RSPOS sy-vline
WA_DET_RMPUIOD_STR-RSART sy-vline
WA_DET_RMPUIOD_STR-BDART sy-vline
WA_DET_RMPUIOD_STR-RQNUM sy-vline
WA_DET_RMPUIOD_STR-RQITM sy-vline
WA_DET_RMPUIOD_STR-LGPBE sy-vline
WA_DET_RMPUIOD_STR-LMINB sy-vline
WA_DET_RMPUIOD_STR-LBSTF sy-vline
WA_DET_RMPUIOD_STR-ARBPL sy-vline
WA_DET_RMPUIOD_STR-ARBTX sy-vline
WA_DET_RMPUIOD_STR-PLNUM sy-vline
WA_DET_RMPUIOD_STR-AUFNR sy-vline
WA_DET_RMPUIOD_STR-DAUTY sy-vline
WA_DET_RMPUIOD_STR-DISPO sy-vline
WA_DET_RMPUIOD_STR-FEVOR sy-vline
WA_DET_RMPUIOD_STR-VERID sy-vline
WA_DET_RMPUIOD_STR-MDV01 sy-vline
WA_DET_RMPUIOD_STR-MDV02 sy-vline
WA_DET_RMPUIOD_STR-LINTX sy-vline
WA_DET_RMPUIOD_STR-BAUGR sy-vline
WA_DET_RMPUIOD_STR-BAUTX sy-vline
WA_DET_RMPUIOD_STR-BDTER sy-vline
WA_DET_RMPUIOD_STR-SBTER sy-vline
WA_DET_RMPUIOD_STR-BDZTP sy-vline
WA_DET_RMPUIOD_STR-NBDMG sy-vline
WA_DET_RMPUIOD_STR-AVAIL sy-vline
WA_DET_RMPUIOD_STR-AVAIL_TOT sy-vline
WA_DET_RMPUIOD_STR-AVOVL sy-vline
WA_DET_RMPUIOD_STR-MISSQ sy-vline
WA_DET_RMPUIOD_STR-EQUAN sy-vline
WA_DET_RMPUIOD_STR-RMISS sy-vline
WA_DET_RMPUIOD_STR-EQUAN_BEA sy-vline
WA_DET_RMPUIOD_STR-ERFME sy-vline
WA_DET_RMPUIOD_STR-MARK sy-vline
WA_DET_RMPUIOD_STR-DETAIL_ICON sy-vline
WA_DET_RMPUIOD_STR-MEINS sy-vline
WA_DET_RMPUIOD_STR-DELB0 sy-vline
WA_DET_RMPUIOD_STR-NUMMER_DELB0 sy-vline
WA_DET_RMPUIOD_STR-LIGHT_ICON sy-vline
WA_DET_RMPUIOD_STR-UNIT2 sy-vline
WA_DET_RMPUIOD_STR-UNIT3 sy-vline
WA_DET_RMPUIOD_STR-UNIT4 sy-vline
WA_DET_RMPUIOD_STR-UNIT5 sy-vline
WA_DET_RMPUIOD_STR-UNIT6 sy-vline
WA_DET_RMPUIOD_STR-UNIT7 sy-vline
WA_DET_RMPUIOD_STR-MEINS1 sy-vline
WA_DET_RMPUIOD_STR-UMREN sy-vline
WA_DET_RMPUIOD_STR-UMREZ sy-vline
WA_DET_RMPUIOD_STR-KZWSO sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.