ABAP Select data from SAP table DDSUX030L into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP DDSUX030L table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to DDSUX030L. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the DDSUX030L table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_DDSUX030L TYPE STANDARD TABLE OF DDSUX030L,
      WA_DDSUX030L TYPE DDSUX030L,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <DDSUX030L> TYPE DDSUX030L.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_DDSUX030L.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM DDSUX030L
  INTO TABLE IT_DDSUX030L.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM DDSUX030L
*  INTO TABLE @DATA(IT_DDSUX030L2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_DDSUX030L INDEX 1 INTO DATA(WA_DDSUX030L2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_DDSUX030L ASSIGNING <DDSUX030L>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<DDSUX030L>-DBASE = 1.
<DDSUX030L>-UUID = 1.
<DDSUX030L>-CRSTAMP = 1.
<DDSUX030L>-ABSTAMP = 1.
<DDSUX030L>-DYSTAMP = 1.
ENDLOOP.

LOOP AT IT_DDSUX030L INTO WA_DDSUX030L.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_DDSUX030L-FLDCNT, sy-vline,
WA_DDSUX030L-TABLEN, sy-vline,
WA_DDSUX030L-KEYCNT, sy-vline,
WA_DDSUX030L-KEYLEN, sy-vline,
WA_DDSUX030L-CLPOS, sy-vline,
WA_DDSUX030L-TABTYPE, sy-vline.
ENDLOOP. *Add any further fields from structure WA_DDSUX030L you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_DDSUX030L TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_DDSUX030L INTO WA_DDSUX030L. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_DDSUX030L_STR,
DBASE TYPE STRING,
UUID TYPE STRING,
CRSTAMP TYPE STRING,
ABSTAMP TYPE STRING,
DYSTAMP TYPE STRING,
FLDCNT TYPE STRING,
TABLEN TYPE STRING,
KEYCNT TYPE STRING,
KEYLEN TYPE STRING,
CLPOS TYPE STRING,
TABTYPE TYPE STRING,
TABFORM TYPE STRING,
REFNAME TYPE STRING,
FLAGBYTE TYPE STRING,
EXROUT TYPE STRING,
FLAG3 TYPE STRING,
FLAG4 TYPE STRING,
FLAG5 TYPE STRING,
FLAG6 TYPE STRING,
BUFSTATE TYPE STRING,
BUFPARM TYPE STRING,
ALIGN TYPE STRING,
POINTERLG TYPE STRING,
UNICODELG TYPE STRING,
COMPCNT TYPE STRING,
LEAFCNT TYPE STRING,
DBSQLTIMESTMP TYPE STRING,
ADD_DATA TYPE STRING,END OF T_EKKO_STR. DATA: WA_DDSUX030L_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_DDSUX030L_STR-DBASE sy-vline
WA_DDSUX030L_STR-UUID sy-vline
WA_DDSUX030L_STR-CRSTAMP sy-vline
WA_DDSUX030L_STR-ABSTAMP sy-vline
WA_DDSUX030L_STR-DYSTAMP sy-vline
WA_DDSUX030L_STR-FLDCNT sy-vline
WA_DDSUX030L_STR-TABLEN sy-vline
WA_DDSUX030L_STR-KEYCNT sy-vline
WA_DDSUX030L_STR-KEYLEN sy-vline
WA_DDSUX030L_STR-CLPOS sy-vline
WA_DDSUX030L_STR-TABTYPE sy-vline
WA_DDSUX030L_STR-TABFORM sy-vline
WA_DDSUX030L_STR-REFNAME sy-vline
WA_DDSUX030L_STR-FLAGBYTE sy-vline
WA_DDSUX030L_STR-EXROUT sy-vline
WA_DDSUX030L_STR-FLAG3 sy-vline
WA_DDSUX030L_STR-FLAG4 sy-vline
WA_DDSUX030L_STR-FLAG5 sy-vline
WA_DDSUX030L_STR-FLAG6 sy-vline
WA_DDSUX030L_STR-BUFSTATE sy-vline
WA_DDSUX030L_STR-BUFPARM sy-vline
WA_DDSUX030L_STR-ALIGN sy-vline
WA_DDSUX030L_STR-POINTERLG sy-vline
WA_DDSUX030L_STR-UNICODELG sy-vline
WA_DDSUX030L_STR-COMPCNT sy-vline
WA_DDSUX030L_STR-LEAFCNT sy-vline
WA_DDSUX030L_STR-DBSQLTIMESTMP sy-vline
WA_DDSUX030L_STR-ADD_DATA sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.