ABAP Select data from SAP table DD24V into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP DD24V table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to DD24V. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the DD24V table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_DD24V TYPE STANDARD TABLE OF DD24V,
      WA_DD24V TYPE DD24V,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <DD24V> TYPE DD24V.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_DD24V.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM DD24V
  INTO TABLE IT_DD24V.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM DD24V
*  INTO TABLE @DATA(IT_DD24V2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_DD24V INDEX 1 INTO DATA(WA_DD24V2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_DD24V ASSIGNING <DD24V>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<DD24V>-MCONAME = 1.
<DD24V>-MCID = 1.
<DD24V>-MCFIELDN = 1.
<DD24V>-DDLANGUAGE = 1.
<DD24V>-POSITION = 1.
ENDLOOP.

LOOP AT IT_DD24V INTO WA_DD24V.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_DD24V-TABNAME, sy-vline,
WA_DD24V-BASEFLDN, sy-vline,
WA_DD24V-OBJPOS, sy-vline,
WA_DD24V-OFFSET, sy-vline,
WA_DD24V-FLENGTH, sy-vline,
WA_DD24V-OUTLINE, sy-vline.
ENDLOOP. *Add any further fields from structure WA_DD24V you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_DD24V TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_DD24V INTO WA_DD24V. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ISOLA, internal->external for field DDLANGUAGE CALL FUNCTION 'CONVERSION_EXIT_ISOLA_OUTPUT' EXPORTING input = WA_DD24V-DDLANGUAGE IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_DD24V-DDLANGUAGE.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_DD24V_STR,
MCONAME TYPE STRING,
MCID TYPE STRING,
MCFIELDN TYPE STRING,
DDLANGUAGE TYPE STRING,
POSITION TYPE STRING,
TABNAME TYPE STRING,
BASEFLDN TYPE STRING,
OBJPOS TYPE STRING,
OFFSET TYPE STRING,
FLENGTH TYPE STRING,
OUTLINE TYPE STRING,
OUTCOL TYPE STRING,
OUTMODFLAG TYPE STRING,
MEMID TYPE STRING,
GPA TYPE STRING,
SPA TYPE STRING,
FLAGS TYPE STRING,
NOUPPER TYPE STRING,
ROLLNAME TYPE STRING,END OF T_EKKO_STR. DATA: WA_DD24V_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_DD24V_STR-MCONAME sy-vline
WA_DD24V_STR-MCID sy-vline
WA_DD24V_STR-MCFIELDN sy-vline
WA_DD24V_STR-DDLANGUAGE sy-vline
WA_DD24V_STR-POSITION sy-vline
WA_DD24V_STR-TABNAME sy-vline
WA_DD24V_STR-BASEFLDN sy-vline
WA_DD24V_STR-OBJPOS sy-vline
WA_DD24V_STR-OFFSET sy-vline
WA_DD24V_STR-FLENGTH sy-vline
WA_DD24V_STR-OUTLINE sy-vline
WA_DD24V_STR-OUTCOL sy-vline
WA_DD24V_STR-OUTMODFLAG sy-vline
WA_DD24V_STR-MEMID sy-vline
WA_DD24V_STR-GPA sy-vline
WA_DD24V_STR-SPA sy-vline
WA_DD24V_STR-FLAGS sy-vline
WA_DD24V_STR-NOUPPER sy-vline
WA_DD24V_STR-ROLLNAME sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.