ABAP Select data from SAP table DB6PDDIAG into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP DB6PDDIAG table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to DB6PDDIAG. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the DB6PDDIAG table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_DB6PDDIAG TYPE STANDARD TABLE OF DB6PDDIAG,
      WA_DB6PDDIAG TYPE DB6PDDIAG,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <DB6PDDIAG> TYPE DB6PDDIAG.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_DB6PDDIAG.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM DB6PDDIAG
  INTO TABLE IT_DB6PDDIAG.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM DB6PDDIAG
*  INTO TABLE @DATA(IT_DB6PDDIAG2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_DB6PDDIAG INDEX 1 INTO DATA(WA_DB6PDDIAG2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_DB6PDDIAG ASSIGNING <DB6PDDIAG>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<DB6PDDIAG>-FACILITY = 1.
<DB6PDDIAG>-RECTYPE = 1.
<DB6PDDIAG>-TIMESTAMP = 1.
<DB6PDDIAG>-TIMEZONE = 1.
<DB6PDDIAG>-INSTANCENAME = 1.
ENDLOOP.

LOOP AT IT_DB6PDDIAG INTO WA_DB6PDDIAG.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_DB6PDDIAG-DBPARTITIONNUM, sy-vline,
WA_DB6PDDIAG-LEVEL, sy-vline,
WA_DB6PDDIAG-IMPACT, sy-vline,
WA_DB6PDDIAG-DBNAME, sy-vline,
WA_DB6PDDIAG-EDU_ID, sy-vline,
WA_DB6PDDIAG-EDUNAME, sy-vline.
ENDLOOP. *Add any further fields from structure WA_DB6PDDIAG you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_DB6PDDIAG TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_DB6PDDIAG INTO WA_DB6PDDIAG. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_DB6PDDIAG_STR,
FACILITY TYPE STRING,
RECTYPE TYPE STRING,
TIMESTAMP TYPE STRING,
TIMEZONE TYPE STRING,
INSTANCENAME TYPE STRING,
DBPARTITIONNUM TYPE STRING,
LEVEL TYPE STRING,
IMPACT TYPE STRING,
DBNAME TYPE STRING,
EDU_ID TYPE STRING,
EDUNAME TYPE STRING,
PID TYPE STRING,
PROCESS_NAME TYPE STRING,
TID TYPE STRING,
APPLHANDLE TYPE STRING,
AUTH_ID TYPE STRING,
PRODUCT TYPE STRING,
COMPONENT TYPE STRING,
FUNCTION TYPE STRING,
PROBE TYPE STRING,
CALLEDPRODUCT TYPE STRING,
CALLEDCOMPONENT TYPE STRING,
CALLEDFUNCTION TYPE STRING,
OSERR TYPE STRING,
RETCODE TYPE STRING,
MSGNUM TYPE STRING,
MSGTYPE TYPE STRING,
MSG TYPE STRING,
OBJTYPE TYPE STRING,
OBJNAME TYPE STRING,
OBJNAME_QUALIFIER TYPE STRING,
EVENTTYPE TYPE STRING,
EVENTDESC TYPE STRING,
FIRST_EVENTQUALIFIERTYPE TYPE STRING,
FIRST_EVENTQUALIFIER TYPE STRING,
SECOND_EVENTQUALIFIERTYPE TYPE STRING,
SECOND_EVENTQUALIFIER TYPE STRING,
THIRD_EVENTQUALIFIERTYPE TYPE STRING,
THIRD_EVENTQUALIFIER TYPE STRING,
EVENTSTATE TYPE STRING,
EVENTATTRIBUTE TYPE STRING,
EVENTSTACK TYPE STRING,
CALLSTACK TYPE STRING,
DUMPFILE TYPE STRING,
FULLREC TYPE STRING,
ICON TYPE STRING,
DATE TYPE STRING,
TIME TYPE STRING,
BGCOLOR TYPE STRING,
MESSAGE_ID TYPE STRING,END OF T_EKKO_STR. DATA: WA_DB6PDDIAG_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_DB6PDDIAG_STR-FACILITY sy-vline
WA_DB6PDDIAG_STR-RECTYPE sy-vline
WA_DB6PDDIAG_STR-TIMESTAMP sy-vline
WA_DB6PDDIAG_STR-TIMEZONE sy-vline
WA_DB6PDDIAG_STR-INSTANCENAME sy-vline
WA_DB6PDDIAG_STR-DBPARTITIONNUM sy-vline
WA_DB6PDDIAG_STR-LEVEL sy-vline
WA_DB6PDDIAG_STR-IMPACT sy-vline
WA_DB6PDDIAG_STR-DBNAME sy-vline
WA_DB6PDDIAG_STR-EDU_ID sy-vline
WA_DB6PDDIAG_STR-EDUNAME sy-vline
WA_DB6PDDIAG_STR-PID sy-vline
WA_DB6PDDIAG_STR-PROCESS_NAME sy-vline
WA_DB6PDDIAG_STR-TID sy-vline
WA_DB6PDDIAG_STR-APPLHANDLE sy-vline
WA_DB6PDDIAG_STR-AUTH_ID sy-vline
WA_DB6PDDIAG_STR-PRODUCT sy-vline
WA_DB6PDDIAG_STR-COMPONENT sy-vline
WA_DB6PDDIAG_STR-FUNCTION sy-vline
WA_DB6PDDIAG_STR-PROBE sy-vline
WA_DB6PDDIAG_STR-CALLEDPRODUCT sy-vline
WA_DB6PDDIAG_STR-CALLEDCOMPONENT sy-vline
WA_DB6PDDIAG_STR-CALLEDFUNCTION sy-vline
WA_DB6PDDIAG_STR-OSERR sy-vline
WA_DB6PDDIAG_STR-RETCODE sy-vline
WA_DB6PDDIAG_STR-MSGNUM sy-vline
WA_DB6PDDIAG_STR-MSGTYPE sy-vline
WA_DB6PDDIAG_STR-MSG sy-vline
WA_DB6PDDIAG_STR-OBJTYPE sy-vline
WA_DB6PDDIAG_STR-OBJNAME sy-vline
WA_DB6PDDIAG_STR-OBJNAME_QUALIFIER sy-vline
WA_DB6PDDIAG_STR-EVENTTYPE sy-vline
WA_DB6PDDIAG_STR-EVENTDESC sy-vline
WA_DB6PDDIAG_STR-FIRST_EVENTQUALIFIERTYPE sy-vline
WA_DB6PDDIAG_STR-FIRST_EVENTQUALIFIER sy-vline
WA_DB6PDDIAG_STR-SECOND_EVENTQUALIFIERTYPE sy-vline
WA_DB6PDDIAG_STR-SECOND_EVENTQUALIFIER sy-vline
WA_DB6PDDIAG_STR-THIRD_EVENTQUALIFIERTYPE sy-vline
WA_DB6PDDIAG_STR-THIRD_EVENTQUALIFIER sy-vline
WA_DB6PDDIAG_STR-EVENTSTATE sy-vline
WA_DB6PDDIAG_STR-EVENTATTRIBUTE sy-vline
WA_DB6PDDIAG_STR-EVENTSTACK sy-vline
WA_DB6PDDIAG_STR-CALLSTACK sy-vline
WA_DB6PDDIAG_STR-DUMPFILE sy-vline
WA_DB6PDDIAG_STR-FULLREC sy-vline
WA_DB6PDDIAG_STR-ICON sy-vline
WA_DB6PDDIAG_STR-DATE sy-vline
WA_DB6PDDIAG_STR-TIME sy-vline
WA_DB6PDDIAG_STR-BGCOLOR sy-vline
WA_DB6PDDIAG_STR-MESSAGE_ID sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.