ABAP Select data from SAP table DB2_VIEW_OMPE_CONFIG into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP DB2_VIEW_OMPE_CONFIG table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to DB2_VIEW_OMPE_CONFIG. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the DB2_VIEW_OMPE_CONFIG table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_DB2_VIEW_OMPE_CONFIG TYPE STANDARD TABLE OF DB2_VIEW_OMPE_CONFIG,
      WA_DB2_VIEW_OMPE_CONFIG TYPE DB2_VIEW_OMPE_CONFIG,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <DB2_VIEW_OMPE_CONFIG> TYPE DB2_VIEW_OMPE_CONFIG.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_DB2_VIEW_OMPE_CONFIG.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM DB2_VIEW_OMPE_CONFIG
  INTO TABLE IT_DB2_VIEW_OMPE_CONFIG.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM DB2_VIEW_OMPE_CONFIG
*  INTO TABLE @DATA(IT_DB2_VIEW_OMPE_CONFIG2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_DB2_VIEW_OMPE_CONFIG INDEX 1 INTO DATA(WA_DB2_VIEW_OMPE_CONFIG2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_DB2_VIEW_OMPE_CONFIG ASSIGNING <DB2_VIEW_OMPE_CONFIG>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<DB2_VIEW_OMPE_CONFIG>-URL_SERV = 1.
<DB2_VIEW_OMPE_CONFIG>-URL_PORT = 1.
<DB2_VIEW_OMPE_CONFIG>-URL_USER = 1.
<DB2_VIEW_OMPE_CONFIG>-URL_PWD = 1.
<DB2_VIEW_OMPE_CONFIG>-URL_PWD_REPEAT = 1.
ENDLOOP.

LOOP AT IT_DB2_VIEW_OMPE_CONFIG INTO WA_DB2_VIEW_OMPE_CONFIG.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_DB2_VIEW_OMPE_CONFIG-PDB_DB_CON, sy-vline,
WA_DB2_VIEW_OMPE_CONFIG-DB_CON_LIST, sy-vline,
WA_DB2_VIEW_OMPE_CONFIG-URL_PROTOCOL, sy-vline,
WA_DB2_VIEW_OMPE_CONFIG-PROTOCOL_LIST, sy-vline,
ENDLOOP. *Add any further fields from structure WA_DB2_VIEW_OMPE_CONFIG you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_DB2_VIEW_OMPE_CONFIG TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_DB2_VIEW_OMPE_CONFIG INTO WA_DB2_VIEW_OMPE_CONFIG. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_DB2_VIEW_OMPE_CONFIG_STR,
URL_SERV TYPE STRING,
URL_PORT TYPE STRING,
URL_USER TYPE STRING,
URL_PWD TYPE STRING,
URL_PWD_REPEAT TYPE STRING,
PDB_DB_CON TYPE STRING,
DB_CON_LIST TYPE STRING,
URL_PROTOCOL TYPE STRING,
PROTOCOL_LIST TYPE STRING,END OF T_EKKO_STR. DATA: WA_DB2_VIEW_OMPE_CONFIG_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_DB2_VIEW_OMPE_CONFIG_STR-URL_SERV sy-vline
WA_DB2_VIEW_OMPE_CONFIG_STR-URL_PORT sy-vline
WA_DB2_VIEW_OMPE_CONFIG_STR-URL_USER sy-vline
WA_DB2_VIEW_OMPE_CONFIG_STR-URL_PWD sy-vline
WA_DB2_VIEW_OMPE_CONFIG_STR-URL_PWD_REPEAT sy-vline
WA_DB2_VIEW_OMPE_CONFIG_STR-PDB_DB_CON sy-vline
WA_DB2_VIEW_OMPE_CONFIG_STR-DB_CON_LIST sy-vline
WA_DB2_VIEW_OMPE_CONFIG_STR-URL_PROTOCOL sy-vline
WA_DB2_VIEW_OMPE_CONFIG_STR-PROTOCOL_LIST sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.