ABAP Select data from SAP table D301T into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP D301T table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to D301T. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the D301T table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_D301T TYPE STANDARD TABLE OF D301T,
      WA_D301T TYPE D301T,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <D301T> TYPE D301T.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_D301T.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM D301T
  INTO TABLE IT_D301T.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM D301T
*  INTO TABLE @DATA(IT_D301T2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_D301T INDEX 1 INTO DATA(WA_D301T2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_D301T ASSIGNING <D301T>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<D301T>-DDLANGUAGE = 1.
<D301T>-DDNAME = 1.
<D301T>-DDSTATE = 1.
<D301T>-DDMODE = 1.
<D301T>-DDVERSION = 1.
ENDLOOP.

LOOP AT IT_D301T INTO WA_D301T.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_D301T-DDPOSITION, sy-vline,
WA_D301T-PROGFUN, sy-vline,
WA_D301T-MENUFUN, sy-vline,
WA_D301T-LONGTEXT, sy-vline,
WA_D301T-SHORTTEXT, sy-vline,
WA_D301T-FASTPATH, sy-vline.
ENDLOOP. *Add any further fields from structure WA_D301T you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_D301T TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_D301T INTO WA_D301T. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ISOLA, internal->external for field DDLANGUAGE CALL FUNCTION 'CONVERSION_EXIT_ISOLA_OUTPUT' EXPORTING input = WA_D301T-DDLANGUAGE IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_D301T-DDLANGUAGE.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_D301T_STR,
DDLANGUAGE TYPE STRING,
DDNAME TYPE STRING,
DDSTATE TYPE STRING,
DDMODE TYPE STRING,
DDVERSION TYPE STRING,
DDPOSITION TYPE STRING,
PROGFUN TYPE STRING,
MENUFUN TYPE STRING,
LONGTEXT TYPE STRING,
SHORTTEXT TYPE STRING,
FASTPATH TYPE STRING,END OF T_EKKO_STR. DATA: WA_D301T_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_D301T_STR-DDLANGUAGE sy-vline
WA_D301T_STR-DDNAME sy-vline
WA_D301T_STR-DDSTATE sy-vline
WA_D301T_STR-DDMODE sy-vline
WA_D301T_STR-DDVERSION sy-vline
WA_D301T_STR-DDPOSITION sy-vline
WA_D301T_STR-PROGFUN sy-vline
WA_D301T_STR-MENUFUN sy-vline
WA_D301T_STR-LONGTEXT sy-vline
WA_D301T_STR-SHORTTEXT sy-vline
WA_D301T_STR-FASTPATH sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.