ABAP Select data from SAP table CWCCAPOVWTP into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP CWCCAPOVWTP table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to CWCCAPOVWTP. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the CWCCAPOVWTP table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_CWCCAPOVWTP TYPE STANDARD TABLE OF CWCCAPOVWTP,
      WA_CWCCAPOVWTP TYPE CWCCAPOVWTP,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <CWCCAPOVWTP> TYPE CWCCAPOVWTP.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_CWCCAPOVWTP.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM CWCCAPOVWTP
  INTO TABLE IT_CWCCAPOVWTP.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM CWCCAPOVWTP
*  INTO TABLE @DATA(IT_CWCCAPOVWTP2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_CWCCAPOVWTP INDEX 1 INTO DATA(WA_CWCCAPOVWTP2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_CWCCAPOVWTP ASSIGNING <CWCCAPOVWTP>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<CWCCAPOVWTP>-MANDT = 1.
<CWCCAPOVWTP>-WORKCENTERINTERNALID = 1.
<CWCCAPOVWTP>-WORKCENTERTYPECODE = 1.
<CWCCAPOVWTP>-CAPACITYCATEGORYALLOCATION = 1.
<CWCCAPOVWTP>-CAPACITYINTERNALID = 1.
ENDLOOP.

LOOP AT IT_CWCCAPOVWTP INTO WA_CWCCAPOVWTP.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_CWCCAPOVWTP-WORKCENTEREVALUATIONHORIZON, sy-vline,
WA_CWCCAPOVWTP-WORKCENTERDESC, sy-vline,
WA_CWCCAPOVWTP-BASEUNIT, sy-vline,
WA_CWCCAPOVWTP-WORKCENTERCUMLTVLOADINTMEPERD, sy-vline,
WA_CWCCAPOVWTP-WORKCENTERMAXUTILZNINTIMEPERD, sy-vline,
WA_CWCCAPOVWTP-WORKCENTERCAPFIRSTOVERLOADWK, sy-vline.
ENDLOOP. *Add any further fields from structure WA_CWCCAPOVWTP you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_CWCCAPOVWTP TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_CWCCAPOVWTP INTO WA_CWCCAPOVWTP. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit CUNIT, internal->external for field BASEUNIT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_CWCCAPOVWTP-BASEUNIT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CWCCAPOVWTP-BASEUNIT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field WORKCENTERCAPACITYUNIT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_CWCCAPOVWTP-WORKCENTERCAPACITYUNIT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CWCCAPOVWTP-WORKCENTERCAPACITYUNIT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field WORKCENTERCAPUNITTEXT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_CWCCAPOVWTP-WORKCENTERCAPUNITTEXT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CWCCAPOVWTP-WORKCENTERCAPUNITTEXT.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_CWCCAPOVWTP_STR,
MANDT TYPE STRING,
WORKCENTERINTERNALID TYPE STRING,
WORKCENTERTYPECODE TYPE STRING,
CAPACITYCATEGORYALLOCATION TYPE STRING,
CAPACITYINTERNALID TYPE STRING,
WORKCENTEREVALUATIONHORIZON TYPE STRING,
WORKCENTERDESC TYPE STRING,
BASEUNIT TYPE STRING,
WORKCENTERCUMLTVLOADINTMEPERD TYPE STRING,
WORKCENTERMAXUTILZNINTIMEPERD TYPE STRING,
WORKCENTERCAPFIRSTOVERLOADWK TYPE STRING,
WORKCENTERCAPFIRSTOVERLOADDTE TYPE STRING,
WORKCENTERCAPACITYBACKLOGINHRS TYPE STRING,
WORKCENTERTOTCAPINTIMEPERIOD TYPE STRING,
CAPACITY TYPE STRING,
WORKCENTERMINUTILZNINTMEPERIOD TYPE STRING,
WORKCENTERCAPFIRSTCRITLLOADWK TYPE STRING,
WORKCENTERCAPFIRSTCRITLLOADDTE TYPE STRING,
WORKCENTERAVGUTILZNINTIMEPERD TYPE STRING,
WORKCENTERTOTAVAILCAPINTMEPERD TYPE STRING,
WORKCENTERTOTUTILZNINTMEPERD TYPE STRING,
CAPACITYEVALUATIONTIMEPERIOD TYPE STRING,
WORKCENTERCAPACITYUNIT TYPE STRING,
WORKCENTERCAPUNITTEXT TYPE STRING,
WORKCENTERAVAILABLECAPACITY TYPE STRING,
WORKCENTERCAPACITYREQUIREMENT TYPE STRING,
WORKCENTER TYPE STRING,
WORKCENTERRESPONSIBLE TYPE STRING,
CAPACITYRESPONSIBLEPLANNER TYPE STRING,
CAPACITYREQUIREMENTORIGIN TYPE STRING,
OPERATIONPLANNINGSTATUSCODE TYPE STRING,
ORDERSTATUSCODE TYPE STRING,
CRITICALITY TYPE STRING,
WORKCENTERAVGUTILZNCRITICALITY TYPE STRING,
PLANT TYPE STRING,
PLANTNAME TYPE STRING,
CAPACITYCATEGORYCODE TYPE STRING,
CAPACITYCATEGORYNAME TYPE STRING,
WRKCTRISUNDRMAINTINTMEPERD TYPE STRING,
WRKCTRMAINTORDAVAILABILITYTXT TYPE STRING,
WORKCENTERFLTRCODEINTMEPERD TYPE STRING,
WORKCENTERGROUP TYPE STRING,
WORKCENTERGROUPTYPE TYPE STRING,
WORKCENTERGROUPDESCRIPTION TYPE STRING,
CAPACITYISPOOLED TYPE STRING,
CURRENTPLANTDATE TYPE STRING,
HORIZONSTARTDATE TYPE STRING,
HORIZONENDDATE TYPE STRING,
CAPEVALBUCKETTYPE TYPE STRING,
CAPEVALSTARTDATE TYPE STRING,
WORKCENTERCATEGORYCODE TYPE STRING,
CAPACITYEVALUATIONHORIZONDATE TYPE STRING,
CAPACITYEVALUATIONOVERDUEDATE TYPE STRING,
SHIFTTABLEHASCHANGED TYPE STRING,END OF T_EKKO_STR. DATA: WA_CWCCAPOVWTP_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_CWCCAPOVWTP_STR-MANDT sy-vline
WA_CWCCAPOVWTP_STR-WORKCENTERINTERNALID sy-vline
WA_CWCCAPOVWTP_STR-WORKCENTERTYPECODE sy-vline
WA_CWCCAPOVWTP_STR-CAPACITYCATEGORYALLOCATION sy-vline
WA_CWCCAPOVWTP_STR-CAPACITYINTERNALID sy-vline
WA_CWCCAPOVWTP_STR-WORKCENTEREVALUATIONHORIZON sy-vline
WA_CWCCAPOVWTP_STR-WORKCENTERDESC sy-vline
WA_CWCCAPOVWTP_STR-BASEUNIT sy-vline
WA_CWCCAPOVWTP_STR-WORKCENTERCUMLTVLOADINTMEPERD sy-vline
WA_CWCCAPOVWTP_STR-WORKCENTERMAXUTILZNINTIMEPERD sy-vline
WA_CWCCAPOVWTP_STR-WORKCENTERCAPFIRSTOVERLOADWK sy-vline
WA_CWCCAPOVWTP_STR-WORKCENTERCAPFIRSTOVERLOADDTE sy-vline
WA_CWCCAPOVWTP_STR-WORKCENTERCAPACITYBACKLOGINHRS sy-vline
WA_CWCCAPOVWTP_STR-WORKCENTERTOTCAPINTIMEPERIOD sy-vline
WA_CWCCAPOVWTP_STR-CAPACITY sy-vline
WA_CWCCAPOVWTP_STR-WORKCENTERMINUTILZNINTMEPERIOD sy-vline
WA_CWCCAPOVWTP_STR-WORKCENTERCAPFIRSTCRITLLOADWK sy-vline
WA_CWCCAPOVWTP_STR-WORKCENTERCAPFIRSTCRITLLOADDTE sy-vline
WA_CWCCAPOVWTP_STR-WORKCENTERAVGUTILZNINTIMEPERD sy-vline
WA_CWCCAPOVWTP_STR-WORKCENTERTOTAVAILCAPINTMEPERD sy-vline
WA_CWCCAPOVWTP_STR-WORKCENTERTOTUTILZNINTMEPERD sy-vline
WA_CWCCAPOVWTP_STR-CAPACITYEVALUATIONTIMEPERIOD sy-vline
WA_CWCCAPOVWTP_STR-WORKCENTERCAPACITYUNIT sy-vline
WA_CWCCAPOVWTP_STR-WORKCENTERCAPUNITTEXT sy-vline
WA_CWCCAPOVWTP_STR-WORKCENTERAVAILABLECAPACITY sy-vline
WA_CWCCAPOVWTP_STR-WORKCENTERCAPACITYREQUIREMENT sy-vline
WA_CWCCAPOVWTP_STR-WORKCENTER sy-vline
WA_CWCCAPOVWTP_STR-WORKCENTERRESPONSIBLE sy-vline
WA_CWCCAPOVWTP_STR-CAPACITYRESPONSIBLEPLANNER sy-vline
WA_CWCCAPOVWTP_STR-CAPACITYREQUIREMENTORIGIN sy-vline
WA_CWCCAPOVWTP_STR-OPERATIONPLANNINGSTATUSCODE sy-vline
WA_CWCCAPOVWTP_STR-ORDERSTATUSCODE sy-vline
WA_CWCCAPOVWTP_STR-CRITICALITY sy-vline
WA_CWCCAPOVWTP_STR-WORKCENTERAVGUTILZNCRITICALITY sy-vline
WA_CWCCAPOVWTP_STR-PLANT sy-vline
WA_CWCCAPOVWTP_STR-PLANTNAME sy-vline
WA_CWCCAPOVWTP_STR-CAPACITYCATEGORYCODE sy-vline
WA_CWCCAPOVWTP_STR-CAPACITYCATEGORYNAME sy-vline
WA_CWCCAPOVWTP_STR-WRKCTRISUNDRMAINTINTMEPERD sy-vline
WA_CWCCAPOVWTP_STR-WRKCTRMAINTORDAVAILABILITYTXT sy-vline
WA_CWCCAPOVWTP_STR-WORKCENTERFLTRCODEINTMEPERD sy-vline
WA_CWCCAPOVWTP_STR-WORKCENTERGROUP sy-vline
WA_CWCCAPOVWTP_STR-WORKCENTERGROUPTYPE sy-vline
WA_CWCCAPOVWTP_STR-WORKCENTERGROUPDESCRIPTION sy-vline
WA_CWCCAPOVWTP_STR-CAPACITYISPOOLED sy-vline
WA_CWCCAPOVWTP_STR-CURRENTPLANTDATE sy-vline
WA_CWCCAPOVWTP_STR-HORIZONSTARTDATE sy-vline
WA_CWCCAPOVWTP_STR-HORIZONENDDATE sy-vline
WA_CWCCAPOVWTP_STR-CAPEVALBUCKETTYPE sy-vline
WA_CWCCAPOVWTP_STR-CAPEVALSTARTDATE sy-vline
WA_CWCCAPOVWTP_STR-WORKCENTERCATEGORYCODE sy-vline
WA_CWCCAPOVWTP_STR-CAPACITYEVALUATIONHORIZONDATE sy-vline
WA_CWCCAPOVWTP_STR-CAPACITYEVALUATIONOVERDUEDATE sy-vline
WA_CWCCAPOVWTP_STR-SHIFTTABLEHASCHANGED sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.