ABAP Select data from SAP table CUPDGCLFNRIDDETS into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP CUPDGCLFNRIDDETS table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to CUPDGCLFNRIDDETS. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the CUPDGCLFNRIDDETS table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_CUPDGCLFNRIDDETS TYPE STANDARD TABLE OF CUPDGCLFNRIDDETS,
      WA_CUPDGCLFNRIDDETS TYPE CUPDGCLFNRIDDETS,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <CUPDGCLFNRIDDETS> TYPE CUPDGCLFNRIDDETS.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_CUPDGCLFNRIDDETS.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM CUPDGCLFNRIDDETS
  INTO TABLE IT_CUPDGCLFNRIDDETS.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM CUPDGCLFNRIDDETS
*  INTO TABLE @DATA(IT_CUPDGCLFNRIDDETS2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_CUPDGCLFNRIDDETS INDEX 1 INTO DATA(WA_CUPDGCLFNRIDDETS2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_CUPDGCLFNRIDDETS ASSIGNING <CUPDGCLFNRIDDETS>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<CUPDGCLFNRIDDETS>-MANDT = 1.
<CUPDGCLFNRIDDETS>-CMPLRQRSLTDNGRSGDSBSCDETSUUID = 1.
<CUPDGCLFNRIDDETS>-CMPLRQRSLTUUID = 1.
<CUPDGCLFNRIDDETS>-CMPLRQVERSUUID = 1.
<CUPDGCLFNRIDDETS>-CREATEDBYUSER = 1.
ENDLOOP.

LOOP AT IT_CUPDGCLFNRIDDETS INTO WA_CUPDGCLFNRIDDETS.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_CUPDGCLFNRIDDETS-LASTCHANGEDBYUSER, sy-vline,
WA_CUPDGCLFNRIDDETS-CLASSIFIEDASDANGEROUSGOOD, sy-vline,
WA_CUPDGCLFNRIDDETS-DANGEROUSGOODSIDNNUMBER, sy-vline,
WA_CUPDGCLFNRIDDETS-DANGEROUSGOODSIDNNUMBERTYPE, sy-vline,
WA_CUPDGCLFNRIDDETS-DANGEROUSGOODSPACKINGGROUP, sy-vline,
WA_CUPDGCLFNRIDDETS-DANGEROUSGOODSLISTITEMVARIANT, sy-vline.
ENDLOOP. *Add any further fields from structure WA_CUPDGCLFNRIDDETS you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_CUPDGCLFNRIDDETS TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_CUPDGCLFNRIDDETS INTO WA_CUPDGCLFNRIDDETS. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_CUPDGCLFNRIDDETS_STR,
MANDT TYPE STRING,
CMPLRQRSLTDNGRSGDSBSCDETSUUID TYPE STRING,
CMPLRQRSLTUUID TYPE STRING,
CMPLRQVERSUUID TYPE STRING,
CREATEDBYUSER TYPE STRING,
LASTCHANGEDBYUSER TYPE STRING,
CLASSIFIEDASDANGEROUSGOOD TYPE STRING,
DANGEROUSGOODSIDNNUMBER TYPE STRING,
DANGEROUSGOODSIDNNUMBERTYPE TYPE STRING,
DANGEROUSGOODSPACKINGGROUP TYPE STRING,
DANGEROUSGOODSLISTITEMVARIANT TYPE STRING,
DNGRSGDSQUALIFGWORDPREFIX TYPE STRING,
DNGRSGDSQUALIFGWORDPREFIXTEXT TYPE STRING,
DNGRSGDSQUALIFGWORDSUFFIX TYPE STRING,
DNGRSGDSQUALIFGWORDSUFFIXTEXT TYPE STRING,
DNGRSGDSTECHNAME1SUBSTUUID TYPE STRING,
DNGRSGDSTECHNAME1SUBSTNAME TYPE STRING,
DNGRSGDSTECHNAME2SUBSTUUID TYPE STRING,
DNGRSGDSTECHNAME2SUBSTNAME TYPE STRING,
DNGRSGDSTECHNAME3SUBSTUUID TYPE STRING,
DNGRSGDSTECHNAME3SUBSTNAME TYPE STRING,
PRODISENVIRONMENTALHAZARDOUS TYPE STRING,END OF T_EKKO_STR. DATA: WA_CUPDGCLFNRIDDETS_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_CUPDGCLFNRIDDETS_STR-MANDT sy-vline
WA_CUPDGCLFNRIDDETS_STR-CMPLRQRSLTDNGRSGDSBSCDETSUUID sy-vline
WA_CUPDGCLFNRIDDETS_STR-CMPLRQRSLTUUID sy-vline
WA_CUPDGCLFNRIDDETS_STR-CMPLRQVERSUUID sy-vline
WA_CUPDGCLFNRIDDETS_STR-CREATEDBYUSER sy-vline
WA_CUPDGCLFNRIDDETS_STR-LASTCHANGEDBYUSER sy-vline
WA_CUPDGCLFNRIDDETS_STR-CLASSIFIEDASDANGEROUSGOOD sy-vline
WA_CUPDGCLFNRIDDETS_STR-DANGEROUSGOODSIDNNUMBER sy-vline
WA_CUPDGCLFNRIDDETS_STR-DANGEROUSGOODSIDNNUMBERTYPE sy-vline
WA_CUPDGCLFNRIDDETS_STR-DANGEROUSGOODSPACKINGGROUP sy-vline
WA_CUPDGCLFNRIDDETS_STR-DANGEROUSGOODSLISTITEMVARIANT sy-vline
WA_CUPDGCLFNRIDDETS_STR-DNGRSGDSQUALIFGWORDPREFIX sy-vline
WA_CUPDGCLFNRIDDETS_STR-DNGRSGDSQUALIFGWORDPREFIXTEXT sy-vline
WA_CUPDGCLFNRIDDETS_STR-DNGRSGDSQUALIFGWORDSUFFIX sy-vline
WA_CUPDGCLFNRIDDETS_STR-DNGRSGDSQUALIFGWORDSUFFIXTEXT sy-vline
WA_CUPDGCLFNRIDDETS_STR-DNGRSGDSTECHNAME1SUBSTUUID sy-vline
WA_CUPDGCLFNRIDDETS_STR-DNGRSGDSTECHNAME1SUBSTNAME sy-vline
WA_CUPDGCLFNRIDDETS_STR-DNGRSGDSTECHNAME2SUBSTUUID sy-vline
WA_CUPDGCLFNRIDDETS_STR-DNGRSGDSTECHNAME2SUBSTNAME sy-vline
WA_CUPDGCLFNRIDDETS_STR-DNGRSGDSTECHNAME3SUBSTUUID sy-vline
WA_CUPDGCLFNRIDDETS_STR-DNGRSGDSTECHNAME3SUBSTNAME sy-vline
WA_CUPDGCLFNRIDDETS_STR-PRODISENVIRONMENTALHAZARDOUS sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.