ABAP Select data from SAP table CSRFIREPNTTP into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP CSRFIREPNTTP table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to CSRFIREPNTTP. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the CSRFIREPNTTP table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_CSRFIREPNTTP TYPE STANDARD TABLE OF CSRFIREPNTTP,
      WA_CSRFIREPNTTP TYPE CSRFIREPNTTP,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <CSRFIREPNTTP> TYPE CSRFIREPNTTP.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_CSRFIREPNTTP.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM CSRFIREPNTTP
  INTO TABLE IT_CSRFIREPNTTP.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM CSRFIREPNTTP
*  INTO TABLE @DATA(IT_CSRFIREPNTTP2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_CSRFIREPNTTP INDEX 1 INTO DATA(WA_CSRFIREPNTTP2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_CSRFIREPNTTP ASSIGNING <CSRFIREPNTTP>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<CSRFIREPNTTP>-MANDT = 1.
<CSRFIREPNTTP>-PCSFTYFIREPOINTPRPTYUUID = 1.
<CSRFIREPNTTP>-PCSFTYPRPTYUUID = 1.
<CSRFIREPNTTP>-CREATIONUTCDATETIME = 1.
<CSRFIREPNTTP>-CREATEDBYUSER = 1.
ENDLOOP.

LOOP AT IT_CSRFIREPNTTP INTO WA_CSRFIREPNTTP.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_CSRFIREPNTTP-LASTCHANGEUTCDATETIME, sy-vline,
WA_CSRFIREPNTTP-LASTCHANGEDBYUSER, sy-vline,
WA_CSRFIREPNTTP-PCSFTYFIREPOINTTEMPLOWRQTYOPTR, sy-vline,
WA_CSRFIREPNTTP-PCSFTYFIREPOINTTEMPLOWRQTY, sy-vline,
WA_CSRFIREPNTTP-PCSFTYFIREPOINTTEMPLOWRQTYTXT, sy-vline,
WA_CSRFIREPNTTP-PCSFTYFIREPOINTTEMPUPRQTYOPTR, sy-vline.
ENDLOOP. *Add any further fields from structure WA_CSRFIREPNTTP you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_CSRFIREPNTTP TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_CSRFIREPNTTP INTO WA_CSRFIREPNTTP. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit CUNIT, internal->external for field PCSFTYFIREPOINTTEMPQTYUNIT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_CSRFIREPNTTP-PCSFTYFIREPOINTTEMPQTYUNIT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CSRFIREPNTTP-PCSFTYFIREPOINTTEMPQTYUNIT.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_CSRFIREPNTTP_STR,
MANDT TYPE STRING,
PCSFTYFIREPOINTPRPTYUUID TYPE STRING,
PCSFTYPRPTYUUID TYPE STRING,
CREATIONUTCDATETIME TYPE STRING,
CREATEDBYUSER TYPE STRING,
LASTCHANGEUTCDATETIME TYPE STRING,
LASTCHANGEDBYUSER TYPE STRING,
PCSFTYFIREPOINTTEMPLOWRQTYOPTR TYPE STRING,
PCSFTYFIREPOINTTEMPLOWRQTY TYPE STRING,
PCSFTYFIREPOINTTEMPLOWRQTYTXT TYPE STRING,
PCSFTYFIREPOINTTEMPUPRQTYOPTR TYPE STRING,
PCSFTYFIREPOINTTEMPUPRQTY TYPE STRING,
PCSFTYFIREPOINTTEMPUPRQTYTXT TYPE STRING,
PCSFTYFIREPOINTTEMPQTYUNIT TYPE STRING,
PCSFTYNOTETEXT TYPE STRING,
PCSFTYASSESSMENTPHRSUUID TYPE STRING,
PCSFTYASSESSMENTPHRSTXT TYPE STRING,
PCSFTYHASNOAPPL TYPE STRING,
PCSFTYHASNODATA TYPE STRING,
UNITOFMEASURENAME TYPE STRING,END OF T_EKKO_STR. DATA: WA_CSRFIREPNTTP_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_CSRFIREPNTTP_STR-MANDT sy-vline
WA_CSRFIREPNTTP_STR-PCSFTYFIREPOINTPRPTYUUID sy-vline
WA_CSRFIREPNTTP_STR-PCSFTYPRPTYUUID sy-vline
WA_CSRFIREPNTTP_STR-CREATIONUTCDATETIME sy-vline
WA_CSRFIREPNTTP_STR-CREATEDBYUSER sy-vline
WA_CSRFIREPNTTP_STR-LASTCHANGEUTCDATETIME sy-vline
WA_CSRFIREPNTTP_STR-LASTCHANGEDBYUSER sy-vline
WA_CSRFIREPNTTP_STR-PCSFTYFIREPOINTTEMPLOWRQTYOPTR sy-vline
WA_CSRFIREPNTTP_STR-PCSFTYFIREPOINTTEMPLOWRQTY sy-vline
WA_CSRFIREPNTTP_STR-PCSFTYFIREPOINTTEMPLOWRQTYTXT sy-vline
WA_CSRFIREPNTTP_STR-PCSFTYFIREPOINTTEMPUPRQTYOPTR sy-vline
WA_CSRFIREPNTTP_STR-PCSFTYFIREPOINTTEMPUPRQTY sy-vline
WA_CSRFIREPNTTP_STR-PCSFTYFIREPOINTTEMPUPRQTYTXT sy-vline
WA_CSRFIREPNTTP_STR-PCSFTYFIREPOINTTEMPQTYUNIT sy-vline
WA_CSRFIREPNTTP_STR-PCSFTYNOTETEXT sy-vline
WA_CSRFIREPNTTP_STR-PCSFTYASSESSMENTPHRSUUID sy-vline
WA_CSRFIREPNTTP_STR-PCSFTYASSESSMENTPHRSTXT sy-vline
WA_CSRFIREPNTTP_STR-PCSFTYHASNOAPPL sy-vline
WA_CSRFIREPNTTP_STR-PCSFTYHASNODATA sy-vline
WA_CSRFIREPNTTP_STR-UNITOFMEASURENAME sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.