ABAP Select data from SAP table CRMT_EVENT_ITEM_CALLBACK into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP CRMT_EVENT_ITEM_CALLBACK table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to CRMT_EVENT_ITEM_CALLBACK. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the CRMT_EVENT_ITEM_CALLBACK table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_CRMT_EVENT_ITEM_CALLBACK TYPE STANDARD TABLE OF CRMT_EVENT_ITEM_CALLBACK,
      WA_CRMT_EVENT_ITEM_CALLBACK TYPE CRMT_EVENT_ITEM_CALLBACK,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <CRMT_EVENT_ITEM_CALLBACK> TYPE CRMT_EVENT_ITEM_CALLBACK.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_CRMT_EVENT_ITEM_CALLBACK.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM CRMT_EVENT_ITEM_CALLBACK
  INTO TABLE IT_CRMT_EVENT_ITEM_CALLBACK.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM CRMT_EVENT_ITEM_CALLBACK
*  INTO TABLE @DATA(IT_CRMT_EVENT_ITEM_CALLBACK2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_CRMT_EVENT_ITEM_CALLBACK INDEX 1 INTO DATA(WA_CRMT_EVENT_ITEM_CALLBACK2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_CRMT_EVENT_ITEM_CALLBACK ASSIGNING <CRMT_EVENT_ITEM_CALLBACK>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<CRMT_EVENT_ITEM_CALLBACK>-SUB_TYPE = 1.
<CRMT_EVENT_ITEM_CALLBACK>-EXE_TIME = 1.
<CRMT_EVENT_ITEM_CALLBACK>-PRIO = 1.
<CRMT_EVENT_ITEM_CALLBACK>-OBJ_NAME = 1.
<CRMT_EVENT_ITEM_CALLBACK>-EVENT = 1.
ENDLOOP.

LOOP AT IT_CRMT_EVENT_ITEM_CALLBACK INTO WA_CRMT_EVENT_ITEM_CALLBACK.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_CRMT_EVENT_ITEM_CALLBACK-ATTRI1, sy-vline,
WA_CRMT_EVENT_ITEM_CALLBACK-FUNC_NAM, sy-vline,
WA_CRMT_EVENT_ITEM_CALLBACK-ERROR_CHECK, sy-vline,
WA_CRMT_EVENT_ITEM_CALLBACK-ONLY_ONE_CALL, sy-vline,
WA_CRMT_EVENT_ITEM_CALLBACK-CHANGED_AT, sy-vline,
WA_CRMT_EVENT_ITEM_CALLBACK-CHANGED_BY, sy-vline.
ENDLOOP. *Add any further fields from structure WA_CRMT_EVENT_ITEM_CALLBACK you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_CRMT_EVENT_ITEM_CALLBACK TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_CRMT_EVENT_ITEM_CALLBACK INTO WA_CRMT_EVENT_ITEM_CALLBACK. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_CRMT_EVENT_ITEM_CALLBACK_STR,
SUB_TYPE TYPE STRING,
EXE_TIME TYPE STRING,
PRIO TYPE STRING,
OBJ_NAME TYPE STRING,
EVENT TYPE STRING,
ATTRI1 TYPE STRING,
FUNC_NAM TYPE STRING,
ERROR_CHECK TYPE STRING,
ONLY_ONE_CALL TYPE STRING,
CHANGED_AT TYPE STRING,
CHANGED_BY TYPE STRING,
CB_FREQ TYPE STRING,
ONLY_HDR TYPE STRING,
ONLY_ITM TYPE STRING,
WHERE_USED TYPE STRING,END OF T_EKKO_STR. DATA: WA_CRMT_EVENT_ITEM_CALLBACK_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_CRMT_EVENT_ITEM_CALLBACK_STR-SUB_TYPE sy-vline
WA_CRMT_EVENT_ITEM_CALLBACK_STR-EXE_TIME sy-vline
WA_CRMT_EVENT_ITEM_CALLBACK_STR-PRIO sy-vline
WA_CRMT_EVENT_ITEM_CALLBACK_STR-OBJ_NAME sy-vline
WA_CRMT_EVENT_ITEM_CALLBACK_STR-EVENT sy-vline
WA_CRMT_EVENT_ITEM_CALLBACK_STR-ATTRI1 sy-vline
WA_CRMT_EVENT_ITEM_CALLBACK_STR-FUNC_NAM sy-vline
WA_CRMT_EVENT_ITEM_CALLBACK_STR-ERROR_CHECK sy-vline
WA_CRMT_EVENT_ITEM_CALLBACK_STR-ONLY_ONE_CALL sy-vline
WA_CRMT_EVENT_ITEM_CALLBACK_STR-CHANGED_AT sy-vline
WA_CRMT_EVENT_ITEM_CALLBACK_STR-CHANGED_BY sy-vline
WA_CRMT_EVENT_ITEM_CALLBACK_STR-CB_FREQ sy-vline
WA_CRMT_EVENT_ITEM_CALLBACK_STR-ONLY_HDR sy-vline
WA_CRMT_EVENT_ITEM_CALLBACK_STR-ONLY_ITM sy-vline
WA_CRMT_EVENT_ITEM_CALLBACK_STR-WHERE_USED sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.