ABAP Select data from SAP table CRMT_CT_INBOX_WF_BOR_ATTRIB into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP CRMT_CT_INBOX_WF_BOR_ATTRIB table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to CRMT_CT_INBOX_WF_BOR_ATTRIB. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the CRMT_CT_INBOX_WF_BOR_ATTRIB table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_CRMT_CT_INBOX_WF_BOR_ATTRIB TYPE STANDARD TABLE OF CRMT_CT_INBOX_WF_BOR_ATTRIB, WA_CRMT_CT_INBOX_WF_BOR_ATTRIB TYPE CRMT_CT_INBOX_WF_BOR_ATTRIB, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: <CRMT_CT_INBOX_WF_BOR_ATTRIB> TYPE CRMT_CT_INBOX_WF_BOR_ATTRIB. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_CRMT_CT_INBOX_WF_BOR_ATTRIB. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM CRMT_CT_INBOX_WF_BOR_ATTRIB INTO TABLE IT_CRMT_CT_INBOX_WF_BOR_ATTRIB. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM CRMT_CT_INBOX_WF_BOR_ATTRIB * INTO TABLE @DATA(IT_CRMT_CT_INBOX_WF_BOR_ATTRIB2). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_CRMT_CT_INBOX_WF_BOR_ATTRIB INDEX 1 INTO DATA(WA_CRMT_CT_INBOX_WF_BOR_ATTRIB2). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_CRMT_CT_INBOX_WF_BOR_ATTRIB ASSIGNING <CRMT_CT_INBOX_WF_BOR_ATTRIB>.*To update a field value using a field symbol simply change the value via the field symbol pointer
<CRMT_CT_INBOX_WF_BOR_ATTRIB>-OBJ_IB_CATID = 1.
<CRMT_CT_INBOX_WF_BOR_ATTRIB>-OBJID = 1.
<CRMT_CT_INBOX_WF_BOR_ATTRIB>-LOGSYS = 1.
<CRMT_CT_INBOX_WF_BOR_ATTRIB>-OBJTYPE = 1.
<CRMT_CT_INBOX_WF_BOR_ATTRIB>-OBJKEY = 1.
ENDLOOP. LOOP AT IT_CRMT_CT_INBOX_WF_BOR_ATTRIB INTO WA_CRMT_CT_INBOX_WF_BOR_ATTRIB. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_CRMT_CT_INBOX_WF_BOR_ATTRIB-DESCRIPT, sy-vline,
WA_CRMT_CT_INBOX_WF_BOR_ATTRIB-SHORTTEXT, sy-vline,
WA_CRMT_CT_INBOX_WF_BOR_ATTRIB-DEF_ATTRIB, sy-vline,
WA_CRMT_CT_INBOX_WF_BOR_ATTRIB-ELEMENT, sy-vline,
WA_CRMT_CT_INBOX_WF_BOR_ATTRIB-TAB_INDEX, sy-vline,
WA_CRMT_CT_INBOX_WF_BOR_ATTRIB-CATID, sy-vline.
ENDLOOP. *Add any further fields from structure WA_CRMT_CT_INBOX_WF_BOR_ATTRIB you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_CRMT_CT_INBOX_WF_BOR_ATTRIB TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_CRMT_CT_INBOX_WF_BOR_ATTRIB INTO WA_CRMT_CT_INBOX_WF_BOR_ATTRIB. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
*Conversion exit ALPHA, internal->external for field LOGSYS CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_CRMT_CT_INBOX_WF_BOR_ATTRIB-LOGSYS IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_CRMT_CT_INBOX_WF_BOR_ATTRIB-LOGSYS.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_CRMT_CT_INBOX_WF_BOR_ATTRIB_STR,
OBJ_IB_CATID TYPE STRING,
OBJID TYPE STRING,
LOGSYS TYPE STRING,
OBJTYPE TYPE STRING,
OBJKEY TYPE STRING,
DESCRIPT TYPE STRING,
SHORTTEXT TYPE STRING,
DEF_ATTRIB TYPE STRING,
ELEMENT TYPE STRING,
TAB_INDEX TYPE STRING,
CATID TYPE STRING,
METHOD TYPE STRING,
DEF_METHOD TYPE STRING,
LEAD_OBJECT TYPE STRING,END OF T_EKKO_STR. DATA: WA_CRMT_CT_INBOX_WF_BOR_ATTRIB_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_CRMT_CT_INBOX_WF_BOR_ATTRIB_STR-OBJ_IB_CATID sy-vline
WA_CRMT_CT_INBOX_WF_BOR_ATTRIB_STR-OBJID sy-vline
WA_CRMT_CT_INBOX_WF_BOR_ATTRIB_STR-LOGSYS sy-vline
WA_CRMT_CT_INBOX_WF_BOR_ATTRIB_STR-OBJTYPE sy-vline
WA_CRMT_CT_INBOX_WF_BOR_ATTRIB_STR-OBJKEY sy-vline
WA_CRMT_CT_INBOX_WF_BOR_ATTRIB_STR-DESCRIPT sy-vline
WA_CRMT_CT_INBOX_WF_BOR_ATTRIB_STR-SHORTTEXT sy-vline
WA_CRMT_CT_INBOX_WF_BOR_ATTRIB_STR-DEF_ATTRIB sy-vline
WA_CRMT_CT_INBOX_WF_BOR_ATTRIB_STR-ELEMENT sy-vline
WA_CRMT_CT_INBOX_WF_BOR_ATTRIB_STR-TAB_INDEX sy-vline
WA_CRMT_CT_INBOX_WF_BOR_ATTRIB_STR-CATID sy-vline
WA_CRMT_CT_INBOX_WF_BOR_ATTRIB_STR-METHOD sy-vline
WA_CRMT_CT_INBOX_WF_BOR_ATTRIB_STR-DEF_METHOD sy-vline
WA_CRMT_CT_INBOX_WF_BOR_ATTRIB_STR-LEAD_OBJECT sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.